Dual-chamber versus single-chamber pacing: no survival or stroke advantage across three large trials — atrial fibrillation modestly reduced (MOST + UKPACE + CTOPP)
Shelf #2297 · Heart, vessels, blood pressure & clotting
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2002–2005.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
Does dual-chamber (physiological) pacing beat single-chamber ventricular pacing on death and stroke in sinus-node dysfunction and AV block?
Balance of the evidence
Six and a half thousand randomised patients across three trials, one consistent answer: the 'physiological' device does not keep people alive or prevent strokes. MOST (2,010 patients with sinus-node dysfunction; median 33.1 months) found death or nonfatal stroke in 21.5% with dual-chamber versus 23.0% with ventricular pacing (P=0.48), while atrial fibrillation was less frequent with dual-chamber pacing (hazard ratio 0.79; 95% CI 0.66 to 0.94; P=0.008), heart-failure scores were better, and quality of life slightly higher. UKPACE (2,021 patients aged 70 or older with high-grade AV block; median 4.6 years for mortality) found annual mortality of 7.4% versus 7.2% (hazard ratio 0.96; 95% CI 0.83 to 1.11) and no differences in atrial fibrillation, heart failure, or thromboembolism — notably, the AF advantage did not replicate in this AV-block population. CTOPP's extended follow-up (2,568 patients; mean 6.4 years) closed the 'delayed benefit' question: no difference in cardiovascular death or stroke, total mortality, or stroke, while the reduction in new atrial fibrillation with physiological pacing persisted (relative risk reduction 20.1%; 95% CI 5.4 to 32.5; P=0.009). LIKELY (no difference) (Tier C): choose pacing mode for symptoms, pacemaker syndrome, and patient preference — not for survival. Where dual-chamber pacing earns its keep on symptoms sits in the individual trials above; the AF reduction is real but has never converted into fewer strokes.
MeSH: Aged · Arrhythmia, Sinus · Atrial Fibrillation · Cardiac Pacing, Artificial · Disease-Free Survival · Female · Heart Failure · Hospitalization · Humans · Male · Pacemaker, Artificial · Quality of Life · Stroke · Stroke Volume · Aged, 80 and over · Cardiovascular Diseases · Heart Block · Incidence · Risk · Bradycardia · Canada · Follow-Up Studies · Treatment Outcome
Cards (4)
Card 1 — MOST 2002: death or stroke 21.5% (dual-chamber) vs 23.0% (ventricular), P=0.48; atrial fibrillation HR 0.79 (P=0.008)
Study: Randomised controlled trial (MOST)
Population: 2,010 patients with sinus-node dysfunction randomised to dual-chamber pacing (1,014) or ventricular pacing (996), followed for a median of 33.1 months. Primary endpoint: death from any cause or nonfatal stroke. Secondaries included the composite of death, stroke, or heart-failure hospitalisation; atrial fibrillation; heart-failure score; pacemaker syndrome; and quality of life.
Summary: MOST 2002: death or stroke 21.5% (dual-chamber) vs 23.0% (ventricular), P=0.48; atrial fibrillation HR 0.79 (P=0.008)
Result: The primary endpoint did not differ significantly (21.5% dual-chamber vs 23.0% ventricular; P=0.48). Atrial fibrillation risk was lower with dual-chamber pacing (hazard ratio 0.79; 95% CI 0.66 to 0.94; P=0.008) and heart-failure scores were better (P<0.001); differences in heart-failure hospitalisation and the death/stroke/heart-failure composite were not significant unadjusted and only marginally significant adjusted. Quality of life was slightly better with dual-chamber pacing. The authors conclude dual-chamber pacing does not improve stroke-free survival but reduces AF, heart-failure signs and symptoms, and slightly improves quality of life.
Watch out: Sinus-node dysfunction only — the AF finding belongs to this population; UKPACE's AV-block patients did not show it. Pre-registration era: no registry ID exists, legitimately.
Source: Lamas GA et al. Ventricular pacing or dual-chamber pacing for sinus-node dysfunction. N Engl J Med. 2002. PMID: 12063369. Registry ID: none (pre-registration-era trial). MeSH: Aged · Arrhythmia, Sinus · Atrial Fibrillation · Cardiac Pacing, Artificial · Disease-Free Survival · Female · Heart Failure · Hospitalization · Humans · Male · Pacemaker, Artificial · Quality of Life · Stroke · Stroke Volume
Estimate type: unadjusted estimate, as stated in the card.
Card 2 — UKPACE 2005: annual mortality 7.4% (dual) vs 7.2% (single) — HR 0.96; no difference in AF, heart failure, or thromboembolism in patients 70 and older
Study: Randomised controlled trial (UKPACE)
Population: 2,021 patients aged 70 years or older undergoing a first pacemaker implant for high-grade AV block at multiple centres, randomised to single-chamber ventricular pacing (1,009; fixed-rate or rate-adaptive) or dual-chamber pacing (1,012). Primary outcome: death from all causes. Secondaries: atrial fibrillation, heart failure, and a composite of stroke, TIA, or other thromboembolism. Median follow-up 4.6 years for mortality, 3 years for cardiovascular events.
Summary: UKPACE 2005: annual mortality 7.4% (dual) vs 7.2% (single) — HR 0.96; no difference in AF, heart failure, or thromboembolism in patients 70 and older
Result: Mean annual mortality was 7.2% in the single-chamber group and 7.4% in the dual-chamber group (hazard ratio 0.96; 95% CI 0.83 to 1.11). There were no significant differences in atrial fibrillation, heart failure, or the stroke/TIA/thromboembolism composite. The authors conclude that in elderly patients with high-grade AV block, pacing mode does not influence death during the first five years or cardiovascular events during the first three.
Watch out: The elderly AV-block population is exactly where dual-chamber devices were being withheld on cost grounds — this trial removed the outcome argument from both sides: no benefit, but also no harm. Pre-registration era: no registry ID.
Source: Toff WD et al. Single-chamber versus dual-chamber pacing for high-grade atrioventricular block. N Engl J Med. 2005. PMID: 16014884. Registry ID: none (pre-registration-era trial). MeSH: Aged · Aged, 80 and over · Cardiac Pacing, Artificial · Cardiovascular Diseases · Female · Follow-Up Studies · Heart Block · Humans · Incidence · Male · Pacemaker, Artificial · Risk
Card 3 — CTOPP extended 2004: at 6.4 years, no difference in cardiovascular death or stroke; new AF reduced 20.1% relative with physiological pacing (P=0.009)
Study: Randomised trial extended follow-up (CTOPP)
Population: 2,568 patients requiring a pacemaker for symptomatic bradycardia, randomised to ventricular pacing (1,474) or physiological pacing (atrial or dual-chamber; 1,094), with follow-up extended from the original 3 years to a mean of 6.4 years to test for a delayed benefit. Primary outcome: stroke or cardiovascular death.
Summary: CTOPP extended 2004: at 6.4 years, no difference in cardiovascular death or stroke; new AF reduced 20.1% relative with physiological pacing (P=0.009)
Result: At a mean follow-up of 6.4 years there was no difference between groups in the primary outcome of cardiovascular death or stroke, nor in total mortality or stroke alone. Development of atrial fibrillation remained significantly lower with physiological pacing (relative risk reduction 20.1%; 95% CI 5.4 to 32.5; P=0.009). The authors conclude the extended study shows no outcome difference, with a persistent reduction in AF development.
Watch out: 'Physiological' pooled atrial and dual-chamber devices; crossover and device upgrades over six years dilute contrasts — which makes the persistent AF signal more notable and the null on events more secure, not less. Pre-registration era: no registry ID.
Source: Tang AS et al. Canadian Trial of Physiological Pacing: Effects of physiological pacing during long-term follow-up. Circulation. 2004 (extended follow-up report). PMID: 14707022. Registry ID: none (pre-registration-era trial). MeSH: Atrial Fibrillation · Bradycardia · Canada · Cardiac Pacing, Artificial · Cardiovascular Diseases · Follow-Up Studies · Humans · Pacemaker, Artificial · Stroke · Treatment Outcome
Card 4 — Synthesis: survival and stroke identical; AF modestly reduced where the atrium is paced — LIKELY (no difference)
Study: Synthesis
Population: 6,599 patients across MOST, UKPACE, and CTOPP (Lamas 2002; Toff 2005; Tang 2004).
Summary: Synthesis: survival and stroke identical; AF modestly reduced where the atrium is paced — LIKELY (no difference)
Result: Death/stroke endpoints null in all three trials (P=0.48; HR 0.96; no difference at 6.4 years); AF reduced in the sinus-node and mixed populations (HR 0.79; relative reduction 20.1%), not in elderly AV block. LIKELY (no difference).
Watch out: This shelf answers the mode question for conventional devices; resynchronisation in reduced-ejection-fraction patients is Shelves #2295 and #2296, a different question with a different answer.
Source: Synthesis of Lamas GA et al. N Engl J Med. 2002 (PMID: 12063369), Toff WD et al. N Engl J Med. 2005 (PMID: 16014884), and Tang AS et al. Circulation. 2004 (PMID: 14707022).