ICD patients who don't need pacing: routine dual-chamber pacing at 70/min caused harm versus backup pacing at 40/min (DAVID)

Shelf #2299 · Heart, vessels, blood pressure & clotting

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2002.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In ICD recipients with ejection fraction of 40% or less and no pacing indication, does dual-chamber rate-responsive pacing at 70/min beat minimal ventricular backup pacing at 40/min on death or heart-failure hospitalisation?

Balance of the evidence

The trial that taught device medicine that pacing itself is a drug with side effects. DAVID randomised 506 patients with standard ICD indications, ejection fraction of 40% or less, no indication for antibradycardia pacing, and no persistent atrial arrhythmias to have their dual-chamber devices programmed to dual-chamber rate-responsive pacing at 70/min (DDDR-70) or to ventricular backup pacing at 40/min (VVI-40). The trial was stopped early: one-year survival free of death or first heart-failure hospitalisation was 83.9% with backup pacing versus 73.3% with dual-chamber pacing (relative hazard 1.61; 95% CI 1.06 to 2.44). The components pointed the same way without individually reaching significance — mortality 6.5% versus 10.1% (relative hazard 1.61; 95% CI 0.84 to 3.09) and heart-failure hospitalisation 13.3% versus 22.6% (relative hazard 1.54; 95% CI 0.97 to 2.46). The mechanism is the unnecessary right-ventricular pacing that an active dual-chamber programme delivers to a ventricle that did not need it — dyssynchrony as iatrogenesis. LIKELY (harm) (Tier C): in ICD patients without a pacing indication, program minimal ventricular pacing. The shelf closes the loop with MOST/UKPACE/CTOPP (Shelf #2297 — mode choice is neutral when pacing is needed) and with MADIT-RIT (Shelf #2293 — restraint in therapy programming): across all three, less unnecessary device activity is better.

MeSH: Adrenergic beta-Antagonists · Aged · Amiodarone · Angiotensin-Converting Enzyme Inhibitors · Anti-Arrhythmia Agents · Anticoagulants · Arrhythmias, Cardiac · Cardiac Pacing, Artificial · Cardiovascular Agents · Catheter Ablation · Defibrillators, Implantable · Digoxin · Diuretics · Female · Heart Failure · Humans · Male · Middle Aged · Pacemaker, Artificial · Single-Blind Method · Survival Analysis · Tachycardia, Ventricular · Ventricular Dysfunction, Left · Warfarin

Cards (2)

Card 1 — DAVID 2002: one-year freedom from death or heart-failure hospitalisation 83.9% (backup VVI-40) vs 73.3% (DDDR-70) — relative hazard 1.61

Study: Randomised single-blind trial, stopped early (DAVID)

Population: 506 patients with standard indications for ICD implantation at 37 US centres (2000–2002), all with left ventricular ejection fraction of 40% or less, no indication for antibradycardia pacing, and no persistent atrial arrhythmias; all received a dual-chamber rate-responsive ICD and maximally tolerated heart-failure therapy, randomised to programming at ventricular backup pacing 40/min (256) or dual-chamber rate-responsive pacing 70/min (250). Primary endpoint: composite of time to death or first hospitalisation for congestive heart failure.

Summary: DAVID 2002: one-year freedom from death or heart-failure hospitalisation 83.9% (backup VVI-40) vs 73.3% (DDDR-70) — relative hazard 1.61

Result: One-year survival free of the composite endpoint was 83.9% for VVI-40 versus 73.3% for DDDR-70 (relative hazard 1.61; 95% CI 1.06 to 2.44). Mortality: 6.5% versus 10.1% (relative hazard 1.61; 95% CI 0.84 to 3.09). Heart-failure hospitalisation: 13.3% versus 22.6% (relative hazard 1.54; 95% CI 0.97 to 2.46) — both components trending in favour of backup pacing. The trial was stopped early. The authors conclude dual-chamber pacing offers no clinical advantage over ventricular backup pacing in this population and may be detrimental.

Watch out: Stopped early, which tends to exaggerate effects; the individual components did not reach significance. The lesson is about pacing burden in patients who do not need pacing — it must not be read as an argument against dual-chamber devices in patients with a genuine pacing indication (Shelf #2297).

Source: Wilkoff BL et al. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA. 2002. PMID: 12495391. Registry ID: none in the fetched record. MeSH: Adrenergic beta-Antagonists · Aged · Amiodarone · Angiotensin-Converting Enzyme Inhibitors · Anti-Arrhythmia Agents · Anticoagulants · Arrhythmias, Cardiac · Cardiac Pacing, Artificial · Cardiovascular Agents · Catheter Ablation · Defibrillators, Implantable · Digoxin · Diuretics · Female · Heart Failure · Humans · Male · Middle Aged · Pacemaker, Artificial · Single-Blind Method · Survival Analysis · Tachycardia, Ventricular · Ventricular Dysfunction, Left · Warfarin

Card 2 — Synthesis: unneeded pacing harmed a failing ventricle — LIKELY (harm)

Study: Synthesis

Population: 506 ICD patients (Wilkoff 2002).

Summary: Synthesis: unneeded pacing harmed a failing ventricle — LIKELY (harm)

Result: Composite event-free survival 83.9% vs 73.3% at one year (relative hazard 1.61 relative against DDDR-70). LIKELY (harm).

Watch out: Single trial, stopped early — kept at LIKELY rather than higher because of the early stop, and because its finding has been corroborated mechanistically by the pacing-burden literature ever since.

Source: Synthesis of Wilkoff BL et al. JAMA. 2002 (PMID: 12495391).