SourceMed · Shelf #2633 in the ask interface
Closed loop in type 1 diabetes pregnancy (AiDAPT): time in the pregnancy target range rose by about 10 points and HbA1c fell — from one trial, on glucose endpoints
Shelf #2633 · Diabetes, glucose & metabolism
POSSIBLE (benefit)
Stamped: 2026-11-28.
Evidence published: 2023–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In pregnant women with type 1 diabetes, does automated insulin delivery (hybrid closed loop) improve glucose control versus standard pump or injection therapy with continuous glucose monitoring?
Balance of the evidence
One randomised programme answers the glucose question convincingly. In AiDAPT, 124 pregnant women with type 1 diabetes using the CamAPS FX hybrid closed-loop system spent 68.2% of time in the pregnancy target range (63–140 mg/dL) versus 55.6% with standard insulin therapy — an adjusted difference of 10.5 percentage points (95% CI 7.0 to 14.0) — with HbA1c 0.31 points lower and no excess of severe hypoglycaemia or ketoacidosis, both groups using CGM throughout (Lee 2023, PMID: 37796241). The prespecified postpartum extension found the advantage held for 6 months after delivery (time in range 72% vs 54%; Lee 2025, PMID: 39884300). What the evidence does not show is equally important: the trial was powered for glucose metrics, not for pre-eclampsia, caesarean delivery or neonatal outcomes, and it tested one system in UK clinics. CGM in pregnancy is homed at shelf #959 (CONCEPTT) and closed-loop therapy outside pregnancy at shelf #561; this shelf is the pregnancy-specific automated-delivery question. POSSIBLE (Tier C: a single trial programme — one randomised trial plus its extension — however clean the result).
MeSH: Adult · Female · Humans · Pregnancy · *Blood Glucose/analysis · Blood Glucose Self-Monitoring · *Diabetes Mellitus, Type 1/blood/complications/drug therapy · Glycated Hemoglobin/analysis · *Hypoglycemic Agents/administration & dosage/adverse effects/therapeutic use · *Insulin/administration & dosage/adverse effects/therapeutic use · *Insulin Infusion Systems/adverse effects · *Pregnancy in Diabetics/blood/drug therapy · Treatment Outcome
Cards (3)
Card 1 — Lee 2023 (AiDAPT): hybrid closed loop in pregnancy with type 1 diabetes raised time in the pregnancy target range from 55.6% to 68.2% — an adjusted gain of 10.5 percentage points — and lowered HbA1c by 0.31 points
Study: Randomised controlled trial (Lee 2023, AiDAPT)
Population: Multicentre randomised trial at nine UK sites: 124 pregnant women with type 1 diabetes and HbA1c at least 6.5% (mean age 31.1 years, mean baseline HbA1c 7.7%) assigned to hybrid closed-loop therapy (CamAPS FX) or standard insulin therapy (pump or injections), both groups using continuous glucose monitoring. Primary outcome: percentage of time in the pregnancy-specific glucose target range (63–140 mg/dL) from 16 weeks' gestation to delivery.
Summary: Lee 2023 (AiDAPT): hybrid closed loop in pregnancy with type 1 diabetes raised time in the pregnancy target range from 55.6% to 68.2% — an adjusted gain of 10.5 percentage points — and lowered HbA1c by 0.31 points
Result: Time in target range was 68.2% ± 10.5% on closed loop versus 55.6% ± 12.5% on standard care (mean adjusted difference 10.5 percentage points, 95% CI 7.0 to 14.0; P < 0.001). Closed-loop participants spent less time hyperglycaemic (difference −10.2 points, 95% CI −13.8 to −6.6), had more overnight time in range (difference 12.3 points, 8.3 to 16.2) and lower HbA1c (difference −0.31 points, −0.50 to −0.12), with little time in hypoglycaemia in either group. Safety: severe hypoglycaemia 6 versus 5 instances, diabetic ketoacidosis 1 in each group, and 12 device-related adverse events in the closed-loop group (7 related to the therapy).
Watch out: Glucose outcomes, not baby outcomes: with 124 women the trial was powered for time in range, and it does not establish fewer pre-eclampsias, caesareans or neonatal admissions. Participants had to be willing and able to use the system from early pregnancy, and the comparator already included CGM for everyone — the gain is the algorithm's, on top of sensor use.
Source: Lee TTM et al. Automated Insulin Delivery in Women with Pregnancy Complicated by Type 1 Diabetes. N Engl J Med. 2023. PMID: 37796241. Registry ID: ISRCTN56898625. MeSH: Adult · Female · Humans · Pregnancy · *Blood Glucose/analysis · Blood Glucose Self-Monitoring · *Diabetes Mellitus, Type 1/blood/complications/drug therapy · Glycated Hemoglobin/analysis · *Hypoglycemic Agents/administration & dosage/adverse effects/therapeutic use · *Insulin/administration & dosage/adverse effects/therapeutic use · *Insulin Infusion Systems/adverse effects · *Pregnancy in Diabetics/blood/drug therapy · Treatment Outcome
Estimate type: adjusted estimate, as stated in the card.
Card 2 — Lee 2025 (AiDAPT postpartum extension): the advantage persisted into the first 6 months after delivery — time in range 72% versus 54%, an adjusted difference of 15 points (same trial, prespecified extension)
Study: Prespecified extension report of a randomised trial (Lee 2025, AiDAPT)
Population: Prespecified extension of the AiDAPT trial: of the 124 randomised women, 57 who remained eligible and consented continued their assigned treatment (hybrid closed loop with CamAPS FX, or standard insulin therapy with CGM) for the first 6 months postpartum. Primary outcome: percentage of time in the standard glucose range (70–180 mg/dL) over 6 months postpartum.
Summary: Lee 2025 (AiDAPT postpartum extension): the advantage persisted into the first 6 months after delivery — time in range 72% versus 54%, an adjusted difference of 15 points (same trial, prespecified extension)
Result: Time in range was 72% ± 12% on closed loop versus 54% ± 17% on standard care (adjusted treatment difference 15 percentage points, 95% CI 7 to 22). Time hyperglycaemic was lower (−14 points, 95% CI −23 to −6) and mean CGM glucose lower (−1.3 mmol/L (≈-23 mg/dL), −2.3 to −0.3) on closed loop; hypoglycaemia time was low and similar (2.4% vs 2.6%), the effect did not vary between months 0–3 and 3–6, and there were no unanticipated safety problems.
Watch out: An extension of the same 124-woman trial, in the 57 women who continued — not independent confirmation, and the continuation group is self-selected from a trial population already able to use the technology. It answers 'should women who used closed loop in pregnancy stop at delivery?' (no) rather than the pregnancy question itself.
Source: Lee TTM et al. Automated insulin delivery during the first 6 months postpartum (AiDAPT): a prespecified extension study. Lancet Diabetes Endocrinol. 2025. PMID: 39884300. Registry ID: ISRCTN56898625 (the AiDAPT trial registration, as stated in the record). MeSH: Humans · Female · Pregnancy · *Diabetes Mellitus, Type 1/drug therapy/blood · Adult · *Insulin/administration & dosage · *Postpartum Period · *Insulin Infusion Systems · *Hypoglycemic Agents/administration & dosage · Blood Glucose/analysis · Blood Glucose Self-Monitoring · *Pregnancy in Diabetics/drug therapy · United Kingdom · Young Adult
Estimate type: adjusted estimate, as stated in the card.
Card 3 — Synthesis: one well-run trial programme shows closed loop clearly improves glucose control in type 1 diabetes pregnancy and after delivery — neonatal and maternal outcome benefits remain unproven
Study: Synthesis
Population: The AiDAPT randomised trial (124 women, nine UK sites) and its prespecified 6-month postpartum extension (57 women), both using the CamAPS FX hybrid closed-loop system against standard insulin therapy with CGM in both arms.
Summary: Synthesis: one well-run trial programme shows closed loop clearly improves glucose control in type 1 diabetes pregnancy and after delivery — neonatal and maternal outcome benefits remain unproven
Result: Pregnancy: time in the pregnancy target range 68.2% versus 55.6% (adjusted difference 10.5 points, 95% CI 7.0 to 14.0), HbA1c 0.31 points lower, no excess severe hypoglycaemia (6 vs 5 events) or ketoacidosis (1 vs 1). Postpartum: time in range 72% versus 54% (adjusted difference 15 points, 7 to 22), hypoglycaemia unchanged. The effect sizes are large for a diabetes technology trial and internally consistent across pregnancy and postpartum, but they rest on a single trial programme, a single system, and glycaemic endpoints.
Watch out: Whether 10 extra points of time in range in pregnancy translates into fewer complicated deliveries or healthier babies is the question that matters most and the one this evidence cannot yet answer; the CONCEPTT trial (shelf #959) showed CGM itself improves some neonatal outcomes, which supports — but does not prove — the same for closed loop. Generalisability beyond motivated, technology-using UK clinic populations is untested.
Source: Synthesis of Lee TTM et al. N Engl J Med. 2023 (PMID: 37796241); Lee TTM et al. Lancet Diabetes Endocrinol. 2025 (PMID: 39884300).
Estimate type: adjusted estimate, as stated in the card.