SourceMed · Shelf #266 in the ask interface

TAVR vs surgical aortic valve replacement, by surgical risk

Shelf #266 · Heart, vessels, blood pressure & clotting

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2011–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

For severe aortic stenosis, when does a transcatheter valve (TAVR) match or beat surgical replacement — and what is not yet known?

Balance of the evidence

Across every surgical-risk stratum tested, TAVR was at least noninferior to surgery on death and stroke: high risk (PARTNER 1), intermediate risk (PARTNER 2), and low risk with either a balloon-expandable valve (PARTNER 3 — the 1-year composite actually favored TAVR) or a self-expanding valve (Evolut Low Risk). TAVR's consistent prices are paravalvular leak and, with the self-expanding valve, pacemakers (17.4% vs 6.1%); surgery's are bleeding, kidney injury, and new atrial fibrillation. The honest limit: these primary reports run 1–2 years. Valve durability over the 10–20 years a younger low-risk patient needs is not in this evidence.

MeSH: Transcatheter Aortic Valve Replacement · Aortic Valve Stenosis · Heart Valve Prosthesis Implantation · Humans

Cards (4)

Card 1 — PARTNER 1 (Smith 2011, high risk): death at 1 year 24.2% vs 26.8% — noninferior, different periprocedural prices

Study: RCT (PARTNER 1, Cohort A), N Engl J Med 2011

Population: 699 high-risk patients with severe aortic stenosis at 25 centers; TAVR with a balloon-expandable bovine pericardial valve (transfemoral or transapical) vs surgical replacement; primary end point death from any cause at 1 year.

Summary: Death from any cause at 1 year 24.2% TAVR vs 26.8% surgery (noninferior); major vascular complications 11.0% vs 3.2%; major bleeding 9.3% vs 19.5% — 699 high-risk patients.

Result: Death at 30 days: 3.4% TAVR vs 6.5% surgery (P=0.07); at 1 year 24.2% vs 26.8% (P=0.44; P=0.001 for noninferiority against a 7.5-point margin). Major stroke at 1 year: 5.1% vs 2.4% (P=0.07). Major vascular complications were more frequent with TAVR (11.0% vs 3.2%, P<0.001); major bleeding (9.3% vs 19.5%) and new-onset atrial fibrillation (8.6% vs 16.0%) were more frequent after surgery.

Watch out: First-generation device and transapical access in a quarter of patients; the stroke numbers numerically favored surgery at both time points without reaching significance.

Source: Smith CR et al. Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients. N Engl J Med. 2011. PMID 21639811 · NCT00530894.

Card 2 — PARTNER 2 (Leon 2016, intermediate risk): death or disabling stroke at 2 years 19.3% vs 21.1% — noninferior

Study: RCT (PARTNER 2), N Engl J Med 2016

Population: 2,032 intermediate-risk patients with severe aortic stenosis at 57 centers; TAVR vs surgical replacement; 76.3% in the transfemoral-access cohort, 23.7% transthoracic; primary end point death from any cause or disabling stroke at 2 years.

Summary: Death or disabling stroke at 2 years 19.3% TAVR vs 21.1% surgery (HR 0.89; noninferior) — 2,032 intermediate-risk patients.

Result: Death or disabling stroke at 2 years: 19.3% TAVR vs 21.1% surgery (HR 0.89, 0.73–1.09; P=0.001 for noninferiority, P=0.25 for superiority). In the transfemoral cohort the rates favored TAVR (HR 0.79); in the transthoracic cohort they were similar. TAVR gave larger valve areas and lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery gave fewer major vascular complications and less paravalvular regurgitation.

Watch out: Noninferiority, not superiority, overall — and the transthoracic-access subgroup did not share the transfemoral subgroup's favorable trend.

Source: Leon MB et al. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. 2016. PMID 27040324 · NCT01314313.

Card 3 — PARTNER 3 (Mack 2019, low risk): the 1-year composite favored TAVR — 8.5% vs 15.1%

Study: RCT (PARTNER 3), N Engl J Med 2019

Population: 1,000 patients with severe aortic stenosis and low surgical risk at 71 centers; mean age 73 years, mean STS risk score 1.9%; transfemoral TAVR with a balloon-expandable valve vs surgery; primary end point (death, stroke, or rehospitalization) at 1 year, as-treated population.

Summary: Death, stroke, or rehospitalization at 1 year 8.5% TAVR vs 15.1% surgery (HR 0.54; superiority P=0.001) — 1,000 low-risk patients, mean age 73 years.

Result: The primary composite at 1 year was 8.5% with TAVR vs 15.1% with surgery (absolute difference −6.6 points; HR 0.54, 0.37–0.79; P<0.001 for noninferiority, P=0.001 for superiority). At 30 days TAVR had lower rates of stroke, of death or stroke, and of new-onset atrial fibrillation, and a shorter index hospitalization. Major vascular complications, new pacemakers, and moderate-or-severe paravalvular regurgitation did not differ significantly.

Watch out: One year is the whole of this report: in a 73-year-old low-risk population, the durability question — how the transcatheter valve performs in years 5–20 — is unanswered by the primary publication.

Source: Mack MJ et al. Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. N Engl J Med. 2019. PMID 30883058 · NCT02675114.

Card 4 — Evolut Low Risk (Forrest 2019): self-expanding TAVR noninferior at 24 months — pacemakers 17.4% vs 6.1%

Study: RCT, Bayesian noninferiority analysis (Evolut Low Risk), N Engl J Med 2019

Population: 1,468 patients with severe aortic stenosis and low surgical risk randomized (procedure attempted in 1,403); mean age 74 years; TAVR with a self-expanding supraannular bioprosthesis vs surgical replacement; primary end point death or disabling stroke at 24 months.

Summary: Death or disabling stroke at 24 months 5.3% TAVR vs 6.7% surgery (noninferior); pacemaker implantation 17.4% vs 6.1%; moderate/severe aortic regurgitation 3.5% vs 0.5% — 1,468 low-risk patients, mean age 74 years.

Result: Estimated incidence of the primary end point at 24 months: 5.3% TAVR vs 6.7% surgery (difference −1.4 points; posterior probability of noninferiority >0.999). At 30 days TAVR had less disabling stroke (0.5% vs 1.7%), bleeding (2.4% vs 7.5%), acute kidney injury (0.9% vs 2.8%), and atrial fibrillation (7.7% vs 35.4%) — but more moderate or severe aortic regurgitation (3.5% vs 0.5%) and more pacemaker implantation ( 17.4% vs 6.1% ). At 12 months valve gradients were lower and orifice areas larger with TAVR.

Watch out: The pacemaker and paravalvular-regurgitation excesses are the standing prices of the self-expanding platform; like PARTNER 3, the primary report is short (24 months) against a lifetime durability question.

Source: Forrest JK et al. (Evolut Low Risk investigators). Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients. N Engl J Med. 2019. PMID 30883053 · NCT02701283.