A dedicated transcatheter valve for pure aortic regurgitation: ALIGN-AR met its safety and one-year mortality performance goals — in a single-arm study of 180 high-risk patients
Shelf #3093 · Heart, vessels, blood pressure & clotting
MAYBE (weak evidence) — a dedicated transcatheter valve achieved acceptable 30-day safety and one-year mortality against prespecified performance goals in high-risk aortic regurgitation, without a randomised comparison
Stamped: 2026-11-28.
Evidence published: 2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients at high surgical risk with severe symptomatic native aortic regurgitation, can dedicated transcatheter aortic valve implantation achieve acceptable one-year outcomes?
Balance of the evidence
MAYBE (weak evidence) — ALIGN-AR (Vahl TP et al., PMID: 38552656) is a prospective single-arm study of the Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) — the specific tested product, named here because transcatheter valves for pure regurgitation are device-specific and not interchangeable — in 180 patients with symptomatic moderate-to-severe or severe native aortic regurgitation at high risk for surgical complications. Technical success was 95%. The 30-day composite safety endpoint occurred in 27% of patients, meeting non-inferiority against a prespecified performance goal of 40.5% (P<0.0001), and one-year all-cause mortality was 7.8%, meeting non-inferiority against a 25% goal (P<0.0001). The price on the face of the record: new pacemaker implantation in 24% of patients, with four deaths (2%) and four strokes (2% disabling, 2% non-disabling as counts of two each) by 30 days. A systematic review of transcatheter treatment for aortic regurgitation (Liu R et al., PMID: 38749505; 31 studies, 1,851 patients) found new-generation dedicated ('on-label') devices achieved 97.8% device success and 2.6% 30-day mortality, better than off-label devices on success, pacemaker, paravalvular leak and mortality. MAYBE (weak evidence): performance goals are a low bar set against historical surgical-era expectations, there is no concurrent control group, and durability beyond one year is unknown.
MeSH: Adolescent · Adult · Aged · Female · Humans · Male · Aortic Valve/diagnostic imaging/surgery · Aortic Valve Insufficiency*/etiology/surgery · Aortic Valve Stenosis*/surgery · Heart Valve Prosthesis* · Prospective Studies · Prosthesis Design · Risk Factors · Transcatheter Aortic Valve Replacement*/adverse effects · Treatment Outcome
Cards (3)
Card 1 — ALIGN-AR 2024: 30-day safety endpoint 27% vs a 40.5% performance goal, and 1-year mortality 7.8% vs a 25% goal — both met; pacemaker implantation 24%
Study: Prospective single-arm pivotal study (ALIGN-AR)
Population: 180 patients (of 346 screened) with symptomatic moderate-to-severe or severe native aortic regurgitation, deemed high risk for mortality or complications after surgical aortic valve replacement by heart team and independent screening, treated with transfemoral implantation of the Trilogy transcatheter heart valve (JenaValve Technology) at 20 US sites. Mean age 75.5 years; 47% women.
Summary: ALIGN-AR 2024: 30-day safety endpoint 27% vs a 40.5% performance goal, and 1-year mortality 7.8% vs a 25% goal — both met; pacemaker implantation 24%
Result: Technical success was achieved in 171 patients (95%). At 30 days there were four deaths (2%), two disabling strokes (1%) and two non-disabling strokes (1%). The primary safety endpoint (Valve Academic Research Consortium-2 composite) occurred in 48 patients (27%, 97.5% CI 19.2 to 34.0), meeting non-inferiority against the 40.5% performance goal (P<0.0001); new pacemaker implantation occurred in 36 patients (24%). The primary efficacy endpoint was met, with one-year all-cause mortality in 14 patients (7.8%, 97.5% CI 3.3 to 12.3) against a 25% performance goal (P<0.0001). The authors report promising short-term clinical and haemodynamic outcomes and signs of left ventricular remodelling, with long-term follow-up necessary.
Watch out: Single-arm: 'non-inferiority' here means beating a prespecified performance goal, not matching a randomised comparator — and a 25% one-year mortality goal is generous. Nearly half of screened patients (48%) were excluded, so the results describe a selected anatomical subset. One in four patients needed a new pacemaker, the highest price on this card, and follow-up beyond one year was still ongoing at publication.
Source: Vahl TP et al. Transcatheter aortic valve implantation in patients with high-risk symptomatic native aortic regurgitation (ALIGN-AR): a prospective, multicentre, single-arm study. Lancet. 2024. PMID: 38552656. Registry ID: NCT04415047. MeSH: Adolescent · Adult · Aged · Female · Humans · Male · Aortic Valve/diagnostic imaging/surgery · Aortic Valve Insufficiency*/etiology/surgery · Aortic Valve Stenosis*/surgery · Heart Valve Prosthesis* · Prospective Studies · Prosthesis Design · Risk Factors · Transcatheter Aortic Valve Replacement*/adverse effects · Treatment Outcome
Card 2 — Liu 2024 meta-analysis: 31 studies, 1,851 patients — dedicated on-label devices beat off-label devices on success (97.8% vs 89.9%), 30-day mortality (2.6% vs 5.1%) and pacemaker rate (6.9% vs 18.4%)
Study: Systematic review / meta-analysis, 31 studies (single-arm series)
Population: Thirty-one studies including 1,851 patients treated with new-generation transcatheter devices for severe aortic regurgitation, searched to April 2023; 1,067 patients (57.6%) received 'on-label' dedicated devices (JenaValve and J-Valve) and the remainder off-label devices designed for stenosis.
Summary: Liu 2024 meta-analysis: 31 studies, 1,851 patients — dedicated on-label devices beat off-label devices on success (97.8% vs 89.9%), 30-day mortality (2.6% vs 5.1%) and pacemaker rate (6.9% vs 18.4%)
Result: For new-generation devices overall, 30-day device success was 94.5%, all-cause mortality 4.2%, permanent pacemaker implantation 8.8%, and greater-than-mild paravalvular leak 1.2%. On-label devices performed significantly better than off-label devices on device success (97.8% versus 89.9%; P<0.001), 30-day mortality (2.6% versus 5.1%; P=0.006), pacemaker implantation (6.9% versus 18.4%; P<0.001) and greater-than-mild paravalvular leak (0.9% versus 3.8%; P=0.003).
Watch out: The underlying studies are single-arm series, so these are pooled proportions and between-study comparisons, not randomised contrasts — centres using dedicated devices may differ systematically from centres improvising with stenosis devices. ALIGN-AR's own pacemaker rate (24%) sits far above this pooled on-label average (6.9%), a reminder that pooled single-arm rates hide wide between-study variation.
Source: Liu R et al. Transcatheter aortic valve replacement for aortic regurgitation: a systematic review and meta-analysis. ESC Heart Failure. 2024. PMID: 38749505. Registry ID: none in the record. MeSH: Humans · Aortic Valve Insufficiency*/surgery · Transcatheter Aortic Valve Replacement*/methods · Aortic Valve/surgery · Heart Valve Prosthesis · Prosthesis Design · Treatment Outcome
Card 3 — Synthesis: a dedicated valve can be implanted successfully in selected high-risk regurgitation patients with acceptable early outcomes — comparative and long-term evidence does not yet exist
Study: Synthesis
Population: ALIGN-AR (180 patients, single-arm, dedicated Trilogy valve) and a 31-study meta-analysis of new-generation devices (1,851 patients).
Summary: Synthesis: a dedicated valve can be implanted successfully in selected high-risk regurgitation patients with acceptable early outcomes — comparative and long-term evidence does not yet exist
Result: Technical/device success: 95% in ALIGN-AR; 94.5% pooled (97.8% on-label). Thirty-day mortality: four deaths (2%) in ALIGN-AR; 4.2% pooled (2.6% on-label). One-year mortality: 7.8% in ALIGN-AR against a 25% performance goal. Pacemaker: 24% in ALIGN-AR; 8.8% pooled. Randomised or concurrent-control evidence: none. MAYBE (weak evidence).
Watch out: Surgery remains the only recommended intervention for native aortic regurgitation in the ALIGN-AR record itself; this shelf answers 'can it be done acceptably in high-risk patients', not 'should it replace surgery'. Device naming follows the tested-product rule: results belong to the Trilogy/JenaValve device and other dedicated devices as studied, and should not be transferred to stenosis valves used off-label. Tier C is set: single-arm evidence only.
Source: Synthesis of Vahl TP et al. Lancet. 2024 (PMID: 38552656); Liu R et al. ESC Heart Failure. 2024 (PMID: 38749505).