Self-expanding transcatheter pulmonary valve (Harmony): 98% had acceptable valve function at a median 13 months in a 243-patient registry — but one in five needed treatment for ventricular arrhythmia
Shelf #3096 · Heart, vessels, blood pressure & clotting
MAYBE (weak evidence) — self-expanding transcatheter pulmonary valve replacement achieved excellent short-term valve function in a multicentre registry, with durability beyond two years and comparative benefit still unproven
Stamped: 2026-11-28.
Evidence published: 2024–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In children and young adults with right-ventricular outflow tract dysfunction after repaired congenital heart disease, does transcatheter pulmonary valve replacement with a self-expanding valve achieve durable valve function without surgery?
Balance of the evidence
MAYBE (weak evidence) — the evidence for the self-expanding Harmony transcatheter pulmonary valve (Medtronic) — the specific tested device, named because transcatheter pulmonary valves are device-specific — is a multicentre US registry (Goldstein BH et al., PMID: 38569760): 243 patients with native or surgically repaired right-ventricular outflow tract pulmonary regurgitation, median age 31 years, 71% with tetralogy of Fallot. Acute technical success was achieved in all but one case, hospital stay was one day in 86%, and at a median follow-up of 13 months 98% of patients had acceptable haemodynamic function, with estimated freedom from the composite of haemodynamic dysfunction or outflow-tract reintervention of 99% at one year and 96% at two years, and freedom from valve-related endocarditis of 98% at one year. The counterweights are on the same card: procedural serious adverse events in 4%, ventricular arrhythmia prompting treatment in 19%, and five deaths during follow-up (one COVID-19, two unknown causes, two bloodstream infection). A systematic review comparing transcatheter with surgical pulmonary valve replacement generally (Chongmelaxme B et al., PMID: 40392782; 28 studies, 16,150 patients, all observational) found lower mortality with the transcatheter route (OR 0.64, 95% CI 0.43 to 0.95 — a 36% relative reduction as reported, with absolute rates not given in the record) but three-fold higher odds of infective endocarditis (OR 3.10, 95% CI 2.22 to 4.33). MAYBE (weak evidence): short-term function is excellent in selected anatomy, but there is no randomised or controlled evidence for this device, and 'durable' beyond two years is exactly what a 13-month median follow-up cannot show.
MeSH: Humans · Adult · Pulmonary Valve*/surgery · Heart Valve Prosthesis Implantation*/adverse effects · Heart Valve Prosthesis* · Cardiac Catheterization/adverse effects · Treatment Outcome · Pulmonary Valve Insufficiency*/surgery/etiology · Registries · Prosthesis Design · Retrospective Studies
Cards (3)
Card 1 — Goldstein 2024 Harmony registry: technical success in all but 1 of 243 patients; 98% acceptable valve function at median 13 months; freedom from dysfunction/reintervention 99% at 1 year, 96% at 2 years
Study: Multicentre registry, single-arm (Harmony TPVR)
Population: 243 consecutive patients with native right-ventricular outflow tract pulmonary regurgitation undergoing transcatheter pulmonary valve replacement with the self-expanding Harmony valve (Medtronic) at 11 US centres to April 2022. Median age 31 years (IQR 19–45); cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%) and other (8%). Primary outcome: composite of haemodynamic dysfunction (more-than-mild regurgitation or mean outflow gradient over 30 mm Hg) and outflow-tract reintervention.
Summary: Goldstein 2024 Harmony registry: technical success in all but 1 of 243 patients; 98% acceptable valve function at median 13 months; freedom from dysfunction/reintervention 99% at 1 year, 96% at 2 years
Result: Acute technical success was achieved in all but one case. Procedural serious adverse events occurred in 4% of cases, with no device embolisation or death; hospital length of stay was one day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (IQR 8–19), 98% of patients had acceptable haemodynamic function; estimated freedom from the composite clinical outcome was 99% at one year and 96% at two years, and freedom from valve-related endocarditis was 98% at one year. Five patients died (COVID-19, one; unknown causes, two; bloodstream infection, two).
Watch out: A registry without a comparator: it can show the device works in patients selected for it, not that it beats surgery or another valve. Median age 31 means the 'children and young adults' of the question are mostly adults in this data; median follow-up of 13 months cannot answer durability, and the 19% treated ventricular arrhythmia rate — in a population already prone to arrhythmia after tetralogy repair — needs longer surveillance, not dismissal.
Source: Goldstein BH et al. Early Outcomes From a Multicenter Transcatheter Self-Expanding Pulmonary Valve Replacement Registry. Journal of the American College of Cardiology. 2024. PMID: 38569760. Registry ID: none in the record. MeSH: Humans · Adult · Pulmonary Valve*/surgery · Heart Valve Prosthesis Implantation*/adverse effects · Heart Valve Prosthesis* · Cardiac Catheterization/adverse effects · Treatment Outcome · Pulmonary Valve Insufficiency*/surgery/etiology · Registries · Prosthesis Design · Retrospective Studies
Card 2 — Chongmelaxme 2025 meta-analysis: transcatheter vs surgical pulmonary valve replacement — mortality OR 0.64 favouring transcatheter, but infective endocarditis OR 3.10 against it (28 observational studies, 16,150 patients)
Study: Systematic review / meta-analysis, 28 observational studies
Population: Twenty-eight studies (16,150 patients) comparing transcatheter pulmonary valve replacement with surgical pulmonary valve replacement in patients with pulmonary valve or right-ventricular outflow tract dysfunction, searched to March 2024; all comparative evidence observational, pooled with random-effects models.
Summary: Chongmelaxme 2025 meta-analysis: transcatheter vs surgical pulmonary valve replacement — mortality OR 0.64 favouring transcatheter, but infective endocarditis OR 3.10 against it (28 observational studies, 16,150 patients)
Result: Compared with surgical replacement, transcatheter replacement was associated with lower mortality over follow-up (OR 0.64, 95% CI 0.43 to 0.95 — described by the authors as a 36% relative reduction in risk; absolute rates are not reported in the record) but three-fold greater odds of infective endocarditis over follow-up (OR 3.10, 95% CI 2.22 to 4.33). No significant differences were observed for 30-day mortality, early pulmonary regurgitation, early endocarditis or early re-intervention, or for regurgitation and re-intervention during follow-up. Results varied by geographical region, publication-year cut-off and country income status. All groups showed improved heart function and relevant post-procedural complications.
Watch out: No randomised trials exist for this comparison, and patients routed to catheter versus surgical replacement differ in anatomy, prior operations and frailty in ways observational pooling cannot undo — the mortality advantage may be selection wearing a treatment's clothes. The endocarditis signal, by contrast, is large, directionally consistent with the Harmony registry's own infection-related deaths, and applies across transcatheter devices, not only the self-expanding one.
Source: Chongmelaxme B et al. Comparative effects of transcatheter versus surgical pulmonary valve replacement: A systematic review and meta-analysis. PLOS ONE. 2025. PMID: 40392782. Registry ID: none in the record. MeSH: Humans · Pulmonary Valve*/surgery · Heart Valve Prosthesis Implantation*/methods/adverse effects · Pulmonary Valve Insufficiency*/surgery · Treatment Outcome · Cardiac Catheterization*/methods
Card 3 — Synthesis: excellent short-term valve function without surgery in selected patients; the open questions are endocarditis, arrhythmia and durability past two years
Study: Synthesis
Population: The Harmony self-expanding valve registry (243 patients, median follow-up 13 months) and a 28-study observational meta-analysis of transcatheter versus surgical pulmonary valve replacement (16,150 patients).
Summary: Synthesis: excellent short-term valve function without surgery in selected patients; the open questions are endocarditis, arrhythmia and durability past two years
Result: Valve function: 98% acceptable at median 13 months; freedom from dysfunction or reintervention 99% at one year, 96% at two years (registry). Comparative outcomes (observational): mortality OR 0.64 favouring transcatheter; endocarditis OR 3.10 against transcatheter; no difference in 30-day mortality or re-intervention. Harms in the registry: serious procedural events 4%, treated ventricular arrhythmia 19%, five deaths. MAYBE (weak evidence).
Watch out: Device results are not a class effect: the Harmony self-expanding valve treats native or patched outflow tracts that balloon-expandable valves often cannot, so registry success reflects both device and anatomy selection. For a child, the relevant horizon is decades and multiple lifetime interventions — a frame no study here reaches. Tier C is set: single-arm registry plus observational comparisons only.
Source: Synthesis of Goldstein BH et al. Journal of the American College of Cardiology. 2024 (PMID: 38569760); Chongmelaxme B et al. PLOS ONE. 2025 (PMID: 40392782).