SourceMed · Shelf #3128 in the ask interface

Letting the ventilator run the weaning: automated systems shortened weaning time by 2.68 days in the 2014 Cochrane review, and the 62-trial update still finds less time on the ventilator — with no mortality difference

Shelf #3128 · Critical care & sepsis

POSSIBLE (benefit) — automated weaning and SBT systems shortened weaning time and ventilation duration in two Cochrane syntheses, with no mortality difference

Stamped: 2026-11-28.

Evidence published: 2014–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In mechanically ventilated adults, do automated weaning and spontaneous-breathing-trial systems shorten weaning time compared with clinician-led weaning?

Balance of the evidence

POSSIBLE (benefit) — for time, not for survival. The 2014 Cochrane review (Burns KEA et al., PMID: 25203308) pooled ten SmartCare trials and 654 participants and found automated weaning cut weaning time by a mean of 2.68 days (95% CI −3.99 to −1.37), shortened time to successful extubation by 0.99 days and ICU stay by 5.70 days, and reduced the proportions ventilated beyond seven days (risk ratio 0.44) and 21 days (risk ratio 0.39), with no effect on mortality or reintubation. The 2025 Cochrane update of the broader closed-loop literature (Rose L et al., PMID: 40678933) — 62 trials, 5,052 participants — found automated systems probably reduce ventilation duration (a 24% relative reduction, 95% CI 18% to 30%, with absolute durations varying by trial), ICU stay (14% relative reduction) and reintubation (risk ratio 0.73, 95% CI 0.59 to 0.89), again with little to no mortality difference (risk ratio 0.94, 95% CI 0.82 to 1.07). Two cautions ride on the face: the 2014 effect was largest against non-protocolised clinician weaning, so part of the gain may be protocolisation rather than automation; and the evidence certainty is low to moderate. POSSIBLE (benefit): automated weaning systems get patients off the ventilator sooner without a shown survival effect or a reintubation penalty.

MeSH: Adult · Automation/instrumentation · Critical Illness · Humans · Intensive Care Units · Length of Stay · Randomized Controlled Trials as Topic · Time Factors · Ventilator Weaning/instrumentation/methods · Ventilators, Mechanical/adverse effects · Work of Breathing

Cards (3)

Card 1 — Burns 2014 (Cochrane review, 10 SmartCare trials, 654 patients): weaning time cut by 2.68 days and ICU stay by 5.70 days — mortality and reintubation unchanged

Study: Cochrane systematic review and meta-analysis (Burns 2014)

Population: Ten randomised and quasi-randomised trials involving 654 invasively ventilated critically ill adults weaned with the SmartCare automated weaning and SBT system versus non-automated weaning strategies; eight trials were judged at low or unclear risk of bias and two at high risk.

Summary: Burns 2014 (Cochrane review, 10 SmartCare trials, 654 patients): weaning time cut by 2.68 days and ICU stay by 5.70 days — mortality and reintubation unchanged

Result: SmartCare decreased weaning time (mean difference −2.68 days, 95% CI −3.99 to −1.37; p<0.0001; seven trials, 495 participants; moderate-quality evidence), time to successful extubation (mean difference −0.99 days, 95% CI −1.89 to −0.09) and length of ICU stay (mean difference −5.70 days, 95% CI −10.54 to −0.85). It reduced the proportions receiving ventilation for longer than seven days (risk ratio 0.44, 95% CI 0.23 to 0.85) and 21 days (risk ratio 0.39, 95% CI 0.18 to 0.86) and total ventilation duration (mean difference −1.68 days, 95% CI −3.33 to −0.03). SmartCare had no effect on time to first successful SBT, mortality, or adverse events, specifically reintubation.

Watch out: One commercial system (SmartCare) supplies all ten trials, and the review's own subgroup analysis hints the advantage shrinks when the control arm is itself protocolised — the machine may partly be a way of enforcing a weaning protocol that good clinician-led care already follows. Evidence quality ranged from low to moderate.

Source: Burns KEA et al. Automated weaning and SBT systems versus non-automated weaning strategies for weaning time in invasively ventilated critically ill adults. Cochrane Database of Systematic Reviews. 2014. PMID: 25203308. MeSH: Adult · Automation/instrumentation · Critical Illness · Humans · Intensive Care Units · Length of Stay · Randomized Controlled Trials as Topic · Time Factors · Ventilator Weaning/instrumentation/methods · Ventilators, Mechanical/adverse effects · Work of Breathing

Card 2 — Rose 2025 (Cochrane update, 62 trials, 5,052 patients): automated closed-loop systems probably cut ventilation duration by a relative 24% and reintubation risk (RR 0.73) — mortality RR 0.94, little to no difference

Study: Cochrane systematic review and meta-analysis, updated (Rose 2025)

Population: Sixty-two randomised trials (59 in adults, 3 in children) with 5,052 participants (4,834 adults, 218 children) receiving invasive mechanical ventilation in intensive care, evaluating ten commercially available automated closed-loop systems and one non-commercial system versus non-automated weaning (non-protocolised usual care or protocolised weaning); searches ran to 2 February 2024.

Summary: Rose 2025 (Cochrane update, 62 trials, 5,052 patients): automated closed-loop systems probably cut ventilation duration by a relative 24% and reintubation risk (RR 0.73) — mortality RR 0.94, little to no difference

Result: Automated closed-loop systems probably reduce the duration of mechanical ventilation (mean difference −0.28 log hours, 95% CI −0.36 to −0.20; 51 RCTs, 3,929 participants; moderate-certainty evidence), translating to a 24% relative reduction (95% CI 18% to 30%) with absolute durations varying across trials. They probably result in little to no difference in mortality (risk ratio 0.94, 95% CI 0.82 to 1.07; 38 RCTs, 3,620 participants, 618 events) and probably reduce ICU length of stay (a 14% relative reduction, 95% CI 9% to 18%) and hospital stay (10% relative reduction). They probably reduce reintubation (risk ratio 0.73, 95% CI 0.59 to 0.89), post-extubation non-invasive ventilation (risk ratio 0.74), prolonged ventilation (risk ratio 0.54) and tracheostomy (risk ratio 0.75). No studies reported health-related quality of life.

Watch out: The pooled ventilation-duration result carries I²=87% heterogeneity, and the log-scale headline means the absolute days saved depend heavily on how long a unit's patients are ventilated at baseline. Children contribute 218 of 5,052 participants, so this remains essentially an adult evidence base; the shelf question is about adults and the adult trials dominate.

Source: Rose L et al. Automated versus non-automated weaning for reducing the duration of mechanical ventilation for critically ill adults and children. Cochrane Database of Systematic Reviews. 2025. PMID: 40678933. MeSH: Adult · Child · Humans · Automation · Bias · Critical Illness/therapy/mortality · Intensive Care Units · Length of Stay/statistics & numerical data · Randomized Controlled Trials as Topic · Respiration, Artificial/methods/statistics & numerical data · Time Factors · Ventilator Weaning/methods/instrumentation/mortality/adverse effects

Card 3 — Synthesis: a decade apart, two Cochrane syntheses agree — the machine weans faster, nobody has shown it saves lives, and reintubation does not rise

Study: Synthesis

Population: Two Cochrane syntheses of randomised trials of automated weaning/closed-loop systems versus non-automated weaning in invasively ventilated ICU patients: 10 SmartCare trials, 654 participants (2014) and 62 closed-loop trials, 5,052 participants (2025).

Summary: Synthesis: a decade apart, two Cochrane syntheses agree — the machine weans faster, nobody has shown it saves lives, and reintubation does not rise

Result: Weaning time: −2.68 days with SmartCare (2014). Ventilation duration: 24% relative reduction (2025). ICU stay: −5.70 days (2014); 14% relative reduction (2025). Mortality: no effect (2014); risk ratio 0.94 (95% CI 0.82 to 1.07) (2025). Reintubation: no increase (2014); risk ratio 0.73 (2025). POSSIBLE (benefit) on time-based outcomes. Tier C is not set: two concordant Cochrane syntheses over dozens of randomised trials, and no mortality-benefit claim is made.

Watch out: The fair comparator matters: where clinician-led weaning is already protocolised and daily, the automation premium is likely smaller than the pooled figures suggest. These systems also shift, rather than remove, clinician work — alarms, overrides and protocol exceptions still need a clinician at the bedside.

Source: Synthesis of Burns KEA et al. Cochrane Database of Systematic Reviews. 2014 (PMID: 25203308); Rose L et al. Cochrane Database of Systematic Reviews. 2025 (PMID: 40678933).