SourceMed · Shelf #3151 in the ask interface

Passive leg raising predicts fluid responsiveness well (AUC 0.95 when cardiac output is measured) — but prediction is not outcome: no PLR-guided resuscitation outcome trial sits in this record

Shelf #3151 · Critical care & sepsis

MAYBE (weak evidence) — passive leg raising reliably predicts fluid responsiveness when cardiac output is measured (AUC 0.95 in two meta-analyses), but no outcome trial of PLR-guided resuscitation is present in this record

Stamped: 2026-11-28.

Evidence published: 2016.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with septic shock, does resuscitation guided by passive-leg-raise fluid-responsiveness testing improve outcomes compared with usual assessment?

Balance of the evidence

MAYBE (weak evidence) — for the outcome question as asked, there is no direct evidence here at all; what exists is diagnostic accuracy, and it is strong only when flow is measured directly. Monnet's meta-analysis of 21 studies and 991 adults (Monnet X et al., PMID: 26825952) found PLR-induced changes in cardiac output predicted fluid responsiveness with pooled sensitivity 0.85 and specificity 0.91 and an area under the ROC curve of 0.95, at a best threshold of a cardiac-output rise of at least 10%; read by pulse pressure instead, sensitivity fell to 0.56 (AUC 0.77). Cherpanath's meta-analysis of 23 trials and 1,013 patients (Cherpanath TGV et al., PMID: 26741579) agrees: sensitivity 86%, specificity 92%, AUC 0.95, with pulse-pressure readings clearly inferior to flow variables. Neither review reports a trial of PLR-guided resuscitation against usual assessment on mortality, organ failure, or any patient outcome — they validate a measurement, not a strategy. So this shelf separates the two claims the question conflates: as a test, PLR with a cardiac-output measurement is reliable; as a resuscitation strategy, its outcome benefit is untested in this record. MAYBE (weak evidence): PLR reliably predicts fluid responsiveness when cardiac output is measured, but whether guiding resuscitation by it improves outcomes in septic shock has not been shown.

MeSH: Cardiac Output/*physiology · Chi-Square Distribution · Critical Illness · *Fluid Therapy · Humans · Intensive Care Units · Leg/*blood supply · Monitoring, Physiologic/methods · *Patient Positioning · ROC Curve · Sensitivity and Specificity

Cards (3)

Card 1 — Monnet 2016 (meta-analysis, 21 studies, 991 patients): PLR cardiac-output change — sensitivity 0.85, specificity 0.91, AUC 0.95; by pulse pressure, sensitivity only 0.56

Study: Systematic review and meta-analysis, 21 studies (Monnet 2016)

Population: Twenty-one studies totalling 991 adult patients and 995 fluid challenges in acute circulatory failure, testing whether passive-leg-raising-induced changes in cardiac output (measured by echocardiography, pulse contour analysis, bioreactance, oesophageal Doppler, thermodilution or suprasternal Doppler) or in arterial pulse pressure predict the response to volume expansion.

Summary: Monnet 2016 (meta-analysis, 21 studies, 991 patients): PLR cardiac-output change — sensitivity 0.85, specificity 0.91, AUC 0.95; by pulse pressure, sensitivity only 0.56

Result: The pooled correlation between PLR-induced and fluid-induced changes in cardiac output was 0.76 (95% CI 0.73 to 0.80). For PLR-induced changes in cardiac output, pooled sensitivity was 0.85 (0.81 to 0.88), pooled specificity 0.91 (0.88 to 0.93), and the area under the ROC curve 0.95±0.01, with a best threshold of a PLR-induced cardiac-output increase of at least 10±2%. For PLR-induced changes in pulse pressure (8 studies, 432 challenges), sensitivity was 0.56, specificity 0.83, and AUC 0.77±0.05. No patient-outcome comparison of PLR-guided versus usual resuscitation is reported.

Watch out: Diagnostic accuracy against a fluid-challenge reference standard is not evidence that acting on the test improves outcomes — and the accurate version of the test requires a cardiac-output monitor; the bedside pulse-pressure version misses nearly half of responders.

Source: Monnet X et al. Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Medicine. 2016. PMID: 26825952. MeSH: Cardiac Output/*physiology · Chi-Square Distribution · Critical Illness · *Fluid Therapy · Humans · Intensive Care Units · Leg/*blood supply · Monitoring, Physiologic/methods · *Patient Positioning · ROC Curve · Sensitivity and Specificity

Card 2 — Cherpanath 2016 (meta-analysis, 23 trials, 1,013 patients): sensitivity 86%, specificity 92%, AUC 0.95 — performance held across ventilation modes and techniques, pulse pressure again inferior

Study: Systematic review and meta-analysis, 23 trials (Cherpanath 2016)

Population: Twenty-three clinical trials totalling 1,013 patients and 1,034 fluid challenges, in which passive leg raising was performed together with a fluid challenge as the gold standard defining fluid responders and non-responders, across varied clinical settings, ventilation modes and measurement techniques.

Summary: Cherpanath 2016 (meta-analysis, 23 trials, 1,013 patients): sensitivity 86%, specificity 92%, AUC 0.95 — performance held across ventilation modes and techniques, pulse pressure again inferior

Result: Pooled sensitivity was 86% (95% CI 79 to 92), pooled specificity 92% (95% CI 88 to 96), and the summary area under the ROC curve was 0.95 (95% CI 0.92 to 0.98). Mode of ventilation, type of fluid, starting position and measurement technique did not affect diagnostic performance. Changes in pulse pressure performed worse than flow variables (sensitivity 58%, 95% CI 44 to 70, versus 85%, 95% CI 78 to 90; p<0.001). No mortality or other patient-outcome data for PLR-guided management are reported.

Watch out: Two meta-analyses agreeing on accuracy still leave the strategy question untouched: neither contains a randomised comparison of PLR-guided resuscitation with usual care. Concordant AUCs should not be mistaken for outcome evidence.

Source: Cherpanath TGV et al. Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials. Critical Care Medicine. 2016. PMID: 26741579. MeSH: Blood Pressure · Cardiac Output · Fluid Therapy/*methods · Hemodynamics/*physiology · Humans · *Leg · Reproducibility of Results

Card 3 — Synthesis: an accurate test in search of an outcome trial — PLR predicts who will respond to fluid; it has not been shown to make resuscitation better

Study: Synthesis

Population: Two systematic reviews and meta-analyses of diagnostic accuracy (21 studies, 991 patients; 23 trials, 1,013 patients), both from 2016.

Summary: Synthesis: an accurate test in search of an outcome trial — PLR predicts who will respond to fluid; it has not been shown to make resuscitation better

Result: PLR-induced cardiac-output change: sensitivity 0.85–0.86, specificity 0.91–0.92, AUC 0.95 in both reviews. PLR by pulse pressure: sensitivity 0.56–0.58. Patient outcomes from PLR-guided resuscitation: not studied in either review. MAYBE (weak evidence), Tier C set: the shelf rests on diagnostic-accuracy evidence for an outcome question.

Watch out: The population of these studies is acute circulatory failure broadly, not septic shock alone, and 'fluid responder' is itself a physiological surrogate — roughly half of shocked patients respond, and responding to fluid is not the same as benefiting from it.

Source: Synthesis of Monnet X et al. Intensive Care Medicine. 2016 (PMID: 26825952); Cherpanath TGV et al. Critical Care Medicine. 2016 (PMID: 26741579).