SourceMed · Shelf #3154 in the ask interface

Drawing less blood in the ICU: conservation devices cut the volume taken by 19–80% in small studies — but the one large trial of small-volume tubes did not significantly cut transfusions in its primary analysis

Shelf #3154 · Critical care & sepsis

MAYBE (weak evidence) — blood-conservation devices reduce the volume of blood taken for testing, but the large STRATUS trial found no significant reduction in red-cell transfusion in its primary analysis

Stamped: 2026-11-28.

Evidence published: 2020–2023.

Last source check: 2026-11-28.

Source correction status: no correction or retraction found at the last source check (2026-11-28).

Question

In ICU patients, do small-volume blood-collection tubes and other blood-conservation devices reduce iatrogenic blood loss and transfusion compared with standard tubes?

Balance of the evidence

MAYBE (weak evidence) — the devices clearly take less blood; whether that saves transfusions is unproven. The systematic review behind this shelf (Siegal DM et al., PMID: 30482081) found 8 studies (1,204 patients) of arterial access devices and reduced-volume tubes, every one reporting less blood taken for laboratory testing than standard practice (range 19%–80%), but all at serious risk of bias and too heterogeneous to pool, with no pooled transfusion result. The one large randomised test, STRATUS (Siegal DM et al., PMID: 37824152), switched 25 Canadian ICUs to small-volume tubes in a stepped-wedge design: in its primary analysis of 21,201 patients, red-cell units per patient per ICU stay did not differ significantly (relative risk 0.91, 95% CI 0.79 to 1.05; P=.19; absolute reduction 7.24 units per 100 patients, 95% CI −3.28 to 19.44); only a prespecified secondary analysis including the COVID-hiatus period reached significance (relative risk 0.88, 95% CI 0.77 to 1.00; P=.04). Specimens with insufficient volume for testing stayed rare (≤0.03%) on both strategies, so the laboratory harm feared from smaller tubes did not materialise. MAYBE (weak evidence): blood-conservation devices reliably reduce the volume of blood drawn, but a transfusion benefit rests on a secondary analysis of a single trial and on small studies at serious risk of bias.

MeSH: Adult · Female · Humans · Male · *Anemia/prevention & control · *Blood Specimen Collection/adverse effects/instrumentation · Blood Transfusion/statistics & numerical data · Blood Volume · *Critical Care/methods · Intensive Care Units · *Vascular Access Devices

Cards (3)

Card 1 — Siegal 2020 (systematic review, 8 studies, 1,204 patients): every study reported less blood taken with conservation devices (19%–80% reduction) — all at serious risk of bias, too heterogeneous to pool

Study: Systematic review (Siegal 2020)

Population: Eight studies (1,204 adult ICU patients) comparing blood-sampling conservation devices with standard care or another intervention, searched to October 5, 2017: five studies of arterial access devices and three of reduced-volume blood collection tubes.

Summary: Siegal 2020 (systematic review, 8 studies, 1,204 patients): every study reported less blood taken with conservation devices (19%–80% reduction) — all at serious risk of bias, too heterogeneous to pool

Result: All studies reported a reduction in the volume of blood taken for laboratory testing with devices compared with standard practice (range 19%–80%). The studies were judged to have serious risk of bias, and because of heterogeneity, pooling for meta-analysis was not considered appropriate — so the review gives no pooled estimate for blood volume and none for transfusion. The authors conclude the devices appear effective at reducing volume taken and that further assessment of clinical outcomes may establish clinical benefit.

Watch out: A volume outcome, not a patient outcome: taking 19%–80% less blood for tests is the mechanism, not the prize. The review cannot say whether any patient avoided a transfusion, and its studies were small and at serious risk of bias — the honest summary is 'less blood drawn, benefit downstream unmeasured here'.

Source: Siegal DM et al. Devices to Reduce the Volume of Blood Taken for Laboratory Testing in ICU Patients: A Systematic Review. Journal of Intensive Care Medicine. 2020. PMID: 30482081. MeSH: Adult · Female · Humans · Male · *Anemia/prevention & control · *Blood Specimen Collection/adverse effects/instrumentation · Blood Transfusion/statistics & numerical data · Blood Volume · *Critical Care/methods · Intensive Care Units · *Vascular Access Devices

Card 2 — STRATUS 2023 (stepped-wedge cluster trial, 25 ICUs, 21,201 patients in the primary analysis): small-volume tubes did not significantly reduce red-cell transfusion (relative risk 0.91; P=.19) — a prespecified secondary analysis did (relative risk 0.88; P=.04)

Study: Stepped-wedge cluster randomised trial (STRATUS, Siegal 2023)

Population: 25 adult medical-surgical ICUs in Canada randomised to transition from standard-volume to small-volume vacuum tubes for laboratory testing (February 2019 to January 2021); the primary analysis covered 21,201 patients admitted for 48 hours or more (mean age 63.5 years; 39.9% female), excluding 6,210 patients admitted during a 5.5-month COVID-19-related trial hiatus; a prespecified secondary analysis included 27,411 patients.

Summary: STRATUS 2023 (stepped-wedge cluster trial, 25 ICUs, 21,201 patients in the primary analysis): small-volume tubes did not significantly reduce red-cell transfusion (relative risk 0.91; P=.19) — a prespecified secondary analysis did (relative risk 0.88; P=.04)

Result: In the primary analysis there was no significant difference in red-cell units per patient per ICU stay (relative risk 0.91, 95% CI 0.79 to 1.05; P=.19; absolute reduction 7.24 red-cell units per 100 patients per ICU stay, 95% CI −3.28 to 19.44). In the prespecified secondary analysis, units per patient per ICU stay decreased after transition to small-volume tubes (relative risk 0.88, 95% CI 0.77 to 1.00; P=.04; absolute reduction 9.84 units per 100 patients, 95% CI 0.24 to 20.76). The transfusion-adjusted haemoglobin decrease was not significantly different in the primary population (mean difference 0.10 g/dL, 95% CI −0.04 to 0.23) and was lower in the secondary population (0.17 g/dL, 95% CI 0.05 to 0.29). Specimens with insufficient quantity for analysis were rare (≤0.03%) before and after transition.

Watch out: The headline depends on which analysis you read: the primary analysis — the one the trial was designed around, excluding the pandemic hiatus — is null, and the significant result comes from the secondary population. A stepped-wedge switch also cannot be blinded, and transfusion thresholds were not controlled, so clinician behaviour around the switch is part of what was measured.

Source: Siegal DM et al. Small-Volume Blood Collection Tubes to Reduce Transfusions in Intensive Care: The STRATUS Randomized Clinical Trial. JAMA. 2023. PMID: 37824152. Registry ID: NCT03578419. MeSH: Female · Humans · Male · Middle Aged · *Anemia/etiology/therapy · *Blood Transfusion · Critical Care · Hemoglobins/analysis · Intensive Care Units · *Blood Specimen Collection/methods

Estimate type: adjusted estimate, as stated in the card.

Card 3 — Synthesis: less blood in the tube rack is certain; fewer transfusions is a secondary-analysis finding in one trial, resting on small biased studies before it

Study: Synthesis

Population: One systematic review of 8 small studies (1,204 patients) of arterial access devices and reduced-volume tubes, plus one 25-ICU stepped-wedge cluster trial (21,201 patients in the primary analysis) of small-volume tubes.

Summary: Synthesis: less blood in the tube rack is certain; fewer transfusions is a secondary-analysis finding in one trial, resting on small biased studies before it

Result: Volume of blood taken: reduced in every study in the review (19%–80%), unpooled. Red-cell transfusion: no significant difference in STRATUS's primary analysis (relative risk 0.91, 95% CI 0.79 to 1.05); a significant reduction in its prespecified secondary analysis (relative risk 0.88, 95% CI 0.77 to 1.00; absolute reduction 9.84 units per 100 patients). Laboratory safety: insufficient specimens ≤0.03% on either tube size. MAYBE (weak evidence).

Watch out: Do not quote the review's 19%–80% volume range as a transfusion effect — the two numbers answer different questions, and only one trial has asked the transfusion question at scale. Tier C is set: the transfusion claim depends on a single trial's secondary analysis and on small studies at serious risk of bias.

Source: Synthesis of Siegal DM et al. Journal of Intensive Care Medicine. 2020 (PMID: 30482081); Siegal DM et al. JAMA. 2023 (PMID: 37824152).