SourceMed · Shelf #3181 in the ask interface

High-volume haemofiltration in septic shock with kidney injury: 28-day mortality 37.9% vs 40.8% in IVOIRE — doubling the dose changed nothing

Shelf #3181 · Critical care & sepsis

POSSIBLE (the treatment made no difference) — IVOIRE and two syntheses found no mortality benefit from high-volume over standard-volume haemofiltration in septic shock with AKI

Stamped: 2026-11-28.

Evidence published: 2013–2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In septic shock with acute kidney injury, does high-volume haemofiltration improve survival compared with standard-volume haemofiltration?

Balance of the evidence

POSSIBLE (the treatment made no difference) — an attractive idea, tested at full dose, with a flat result. IVOIRE randomised 140 patients with septic shock and acute kidney injury to high-volume haemofiltration at 70 mL/kg/h or standard-volume at 35 mL/kg/h for 96 hours; 28-day mortality was 37.9% versus 40.8% (p=0.94), with no significant difference in any secondary endpoint, and the trial stopped early for slow accrual. The meta-analysis of four trials (470 participants) found the same: 28-day mortality odds ratio 0.76 (95% CI 0.45 to 1.29), no significant difference in kidney recovery or lengths of stay, and more hypophosphataemia and hypokalaemia at high volume. The Cochrane review (four trials, 200 participants) pooled a 28-day mortality risk ratio of 0.89 (95% CI 0.60 to 1.32) on low-quality evidence. POSSIBLE (the treatment made no difference): high-volume haemofiltration, as applied in these trials, does not reduce mortality in septic shock with AKI and cannot be recommended for that purpose.

MeSH: Acute Kidney Injury/complications/mortality · Aged · Critical Illness · Female · Hemofiltration/methods · Humans · Male · Middle Aged · Prospective Studies · Shock, Septic/complications/mortality/therapy · Survival Rate · Time Factors

Cards (4)

Card 1 — IVOIRE (Joannes-Boyau 2013): 28-day mortality 37.9% (70 mL/kg/h) vs 40.8% (35 mL/kg/h), p=0.94 — stopped early at 140 patients

Study: Randomised multicentre trial (Joannes-Boyau 2013, IVOIRE)

Population: 140 critically ill patients with septic shock and acute kidney injury for less than 24 hours, enrolled at 18 ICUs in France, Belgium, and the Netherlands (2005–2010), randomised to high-volume haemofiltration at 70 mL/kg/h or standard-volume at 35 mL/kg/h for 96 hours; 137 analysed (66 high-volume, 71 standard).

Summary: IVOIRE (Joannes-Boyau 2013): 28-day mortality 37.9% (70 mL/kg/h) vs 40.8% (35 mL/kg/h), p=0.94 — stopped early at 140 patients

Result: Mortality at 28 days was lower than expected but not different between groups (high-volume 37.9% vs standard-volume 40.8%; log-rank p=0.94). There were no statistically significant differences in any secondary endpoint, including haemodynamic profile and organ function. The trial was stopped prematurely because of slow accrual and exhausted resources.

Watch out: Early stopping at 140 patients leaves the trial underpowered for modest effects — but the point estimate is a 3-point difference in the wrong-sized package, and every synthesis since has centred on the same null. 'High volume' here means 70 mL/kg/h; still-higher doses were not tested.

Source: Joannes-Boyau O et al. High-volume versus standard-volume haemofiltration for septic shock patients with acute kidney injury (IVOIRE study): a multicentre randomized controlled trial. Intensive care medicine. 2013. PMID: 23740278. Registry ID: NCT00241228. MeSH: Acute Kidney Injury/complications/mortality · Aged · Critical Illness · Female · Hemofiltration/methods · Humans · Male · Middle Aged · Prospective Studies · Shock, Septic/complications/mortality/therapy · Survival Rate · Time Factors

Card 2 — Clark 2014 meta-analysis: four trials, 470 patients — mortality OR 0.76 (95% CI 0.45 to 1.29), more electrolyte losses at high volume

Study: Systematic review and meta-analysis (Clark 2014)

Population: Four randomised trials (470 participants) comparing high-volume haemofiltration (effluent rate >50 mL/kg/h) with standard-volume haemofiltration in sepsis and septic shock with acute kidney injury, from publications between 1966 and 2013.

Summary: Clark 2014 meta-analysis: four trials, 470 patients — mortality OR 0.76 (95% CI 0.45 to 1.29), more electrolyte losses at high volume

Result: Pooled 28-day mortality did not differ meaningfully between high-volume and standard-volume haemofiltration (OR 0.76, 95% CI 0.45 to 1.29). No included study reported a significant difference in kidney-function recovery, ICU or hospital stay, or vasopressor dose reduction. Adverse events including hypophosphataemia and hypokalaemia were more commonly observed with high-volume treatment, though reporting was inconsistent.

Watch out: Four small trials with differing dose definitions and populations; the confidence interval cannot exclude a moderate benefit or harm, which is precisely why the authors concluded the evidence supports experimental use only.

Source: Clark E et al. High-volume hemofiltration for septic acute kidney injury: a systematic review and meta-analysis. Critical care (London, England). 2014. PMID: 24398168. MeSH: Acute Kidney Injury/diagnosis/epidemiology/therapy · Hemofiltration/methods · Humans · Randomized Controlled Trials as Topic/methods · Sepsis/diagnosis/epidemiology/therapy

Card 3 — Cochrane review (Borthwick 2017): pooled 28-day mortality RR 0.89 (95% CI 0.60 to 1.32) — low-quality evidence, four small trials

Study: Systematic review (Cochrane, Borthwick 2017)

Population: Four randomised trials involving 200 participants with severe sepsis or septic shock in intensive care, comparing high-volume haemofiltration or haemodiafiltration with standard dialysis therapy or none; searches to 31 December 2015.

Summary: Cochrane review (Borthwick 2017): pooled 28-day mortality RR 0.89 (95% CI 0.60 to 1.32) — low-quality evidence, four small trials

Result: The pooled risk ratio for 28-day mortality with high-volume haemofiltration was 0.89 (95% CI 0.60 to 1.32; two trials, 146 participants; low-quality evidence). One study (137 participants) reported ICU length of stay; organ dysfunction and haemodynamic outcomes could not be pooled owing to differing reporting. Investigators reported no adverse events in the included studies.

Watch out: The Cochrane participant total (200) is smaller than the Clark meta-analysis total (470) because of differing inclusion rules — the two syntheses are not independent confirmations so much as overlapping windows on the same four-to-five small trials, all underpowered.

Source: Borthwick EM et al. High-volume haemofiltration for sepsis in adults. The Cochrane database of systematic reviews. 2017. PMID: 28141912. MeSH: Adult · Critical Illness/mortality · Hemodiafiltration/methods · Hemofiltration/methods/mortality · Hospital Mortality · Humans · Intensive Care Units · Organ Dysfunction Scores · Randomized Controlled Trials as Topic · Sepsis/mortality/therapy · Shock, Septic/mortality/therapy · Time Factors

Card 4 — Synthesis: the dose-doubling experiment has been run — in a trial and in two syntheses — and survival does not move

Study: Synthesis

Population: One multicentre RCT (137 analysed) of 70 vs 35 mL/kg/h haemofiltration in septic shock with AKI, a meta-analysis of four trials (470 participants), and a Cochrane review of four trials (200 participants).

Summary: Synthesis: the dose-doubling experiment has been run — in a trial and in two syntheses — and survival does not move

Result: 28-day mortality: 37.9% vs 40.8% in IVOIRE (p=0.94); pooled OR 0.76 (95% CI 0.45 to 1.29) in the meta-analysis; pooled RR 0.89 (95% CI 0.60 to 1.32) in Cochrane. Kidney recovery and lengths of stay: no significant differences. Electrolyte adverse events (hypophosphataemia, hypokalaemia) commoner at high volume. POSSIBLE (the treatment made no difference).

Watch out: This verdict is about filtration dose as solute clearance; it does not address adsorptive or endotoxin-targeted extracorporeal devices, which ask different questions and live elsewhere. Standard-volume filtration for conventional renal indications is untouched by this shelf.

Source: Synthesis of Joannes-Boyau O et al. Intensive care medicine. 2013 (PMID: 23740278); Clark E et al. Critical care (London, England). 2014 (PMID: 24398168); Borthwick EM et al. The Cochrane database of systematic reviews. 2017 (PMID: 28141912).