SourceMed · Shelf #3202 in the ask interface

Oxygenated machine perfusion of donor kidneys: fewer graft failures in DCD kidneys in one trial, no gain at all when added briefly before implantation in expanded-criteria kidneys in another

Shelf #3202 · Kidney, fluids & electrolytes

SPLIT — continuous oxygenated perfusion in DCD kidneys: primary eGFR outcome null but graft failure 3% vs 10% on secondary analysis; brief end-perfusion after cold storage in expanded-criteria kidneys: no benefit on any outcome

Stamped: 2026-11-28.

Evidence published: 2020–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In deceased-donor kidney transplantation, does oxygenated hypothermic machine perfusion reduce delayed graft function and improve graft survival compared with static cold storage or standard (non-oxygenated) perfusion?

Balance of the evidence

SPLIT — the answer splits by how and in which kidneys the oxygen is given. In COMPARE (Jochmans I et al., PMID: 33220737), a paired double-blind phase 3 trial in kidneys donated after circulatory death, continuous oxygenated hypothermic machine perfusion did not significantly improve the primary outcome — 12-month eGFR was 50.5 versus 46.7 mL/min/1.73 m2 (mean difference 3.7, 95% CI -1.0 to 8.4; p=0.12) — but graft failure was lower (3 of 106 [3%] versus 11 of 106 [10%]; hazard ratio 0.27, 95% CI 0.07 to 0.95; p=0.028) and severe complications were fewer (11% versus 16%; p=0.032). In Husen P et al. (PMID: 33881456), short end-perfusion with oxygen after static cold storage in expanded-criteria brain-dead-donor kidneys changed nothing: 1-year graft survival was 92.1% versus 93.3% (P=.71), with no significant differences in delayed graft function, primary nonfunction, eGFR, or acute rejection. SPLIT: continuous oxygenation throughout preservation may protect DCD kidneys (secondary outcomes only, primary null); a brief oxygenated reconditioning at the end of cold storage does not help expanded-criteria kidneys.

MeSH: Cold Temperature · Double-Blind Method · Europe · Female · Glomerular Filtration Rate · Humans · Kidney Transplantation · Male · Middle Aged · Organ Preservation · Oxygen/physiology · Perfusion · Tissue Survival · Tissue and Organ Harvesting

Cards (3)

Card 1 — Jochmans 2020 (COMPARE): 12-month eGFR 50.5 vs 46.7 mL/min/1.73 m2 (p=0.12, not significant) — but graft failure 3% vs 10% (HR 0.27) and severe complications 11% vs 16%

Study: Randomised double-blind paired phase 3 trial (Jochmans 2020, COMPARE)

Population: Kidney pairs from donors aged 50 years or older donated after circulatory death at 19 European transplant centres: 197 pairs randomised, 106 pairs transplanted into eligible recipients; one kidney of each pair received oxygenated hypothermic machine perfusion (HMPO2), the other standard hypothermic machine perfusion, from retrieval to implantation.

Summary: Jochmans 2020 (COMPARE): 12-month eGFR 50.5 vs 46.7 mL/min/1.73 m2 (p=0.12, not significant) — but graft failure 3% vs 10% (HR 0.27) and severe complications 11% vs 16%

Result: Mean eGFR at 12 months was 50.5 mL/min per 1.73 m2 (SD 19.3) in the HMPO2 group versus 46.7 (17.1) in the HMP group (mean difference 3.7 mL/min per 1.73 m2, 95% CI -1.0 to 8.4; p=0.12) — the primary outcome was not significant. Fewer severe complications (Clavien-Dindo grade IIIb or more) were reported with HMPO2 (46 of 417, 11%, 95% CI 8% to 14%) than HMP (76 of 474, 16%, 13% to 20%; p=0.032). Graft failure was lower with HMPO2 (three [3%] of 106) compared with HMP (11 [10%] of 106; hazard ratio 0.27, 95% CI 0.07 to 0.95; p=0.028).

Watch out: The graft-failure and complication benefits are secondary outcomes in a trial whose primary outcome was null, and 23 pairs were excluded from the primary analysis because of kidney failure or patient death — the very events the secondary analysis counts. Fourteen graft failures in total is a small base for a survival claim.

Source: Jochmans I et al. Oxygenated versus standard cold perfusion preservation in kidney transplantation (COMPARE): a randomised, double-blind, paired, phase 3 trial. Lancet. 2020. PMID: 33220737. Registry ID: ISRCTN32967929. MeSH: Cold Temperature · Double-Blind Method · Europe · Female · Glomerular Filtration Rate · Humans · Kidney Transplantation · Male · Middle Aged · Organ Preservation · Oxygen/physiology · Perfusion · Tissue Survival · Tissue and Organ Harvesting

Card 2 — Husen 2021: oxygenated end-perfusion after cold storage — 1-year graft survival 92.1% vs 93.3% (P=.71), and delayed graft function, eGFR and rejection all unchanged

Study: Randomised multicentre trial (Husen 2021)

Population: 305 kidneys from expanded criteria donors (brain-dead; median donor age 64 years, range 50–84) at centres in five European countries, randomised to static cold storage alone or cold storage followed by oxygenated end-hypothermic machine perfusion (minimum 120 minutes; median 4.7 hours) before implantation; 262 kidneys were successfully transplanted (127 end-perfusion, 135 cold storage).

Summary: Husen 2021: oxygenated end-perfusion after cold storage — 1-year graft survival 92.1% vs 93.3% (P=.71), and delayed graft function, eGFR and rejection all unchanged

Result: One-year graft survival was 92.1% (n=117) in the end-perfusion group versus 93.3% (n=126) in the cold-storage group (95% CI, -7.5 to 5.1; P=.71). The secondary endpoint analysis showed no significant between-group differences for delayed graft function, primary nonfunction, estimated glomerular filtration rate, and acute rejection.

Watch out: The trial was single-blind and, by its authors' account, underpowered because overall graft survival was higher than expected; a null here does not exclude a small effect. But it is a direct randomised test of the add-oxygen-at-the-end strategy, and it found nothing on any endpoint.

Source: Husen P et al. Oxygenated End-Hypothermic Machine Perfusion in Expanded Criteria Donor Kidney Transplant: A Randomized Clinical Trial. JAMA Surgery. 2021. PMID: 33881456. Registry ID: ISRCTN63852508. MeSH: Aged · Aged, 80 and over · Cold Ischemia · Delayed Graft Function/epidemiology · Female · Glomerular Filtration Rate · Graft Rejection/epidemiology · Graft Survival · Humans · Kidney Diseases/mortality/surgery · Kidney Transplantation · Male · Middle Aged · Organ Preservation · Perfusion · Prospective Studies · Refrigeration · Single-Blind Method · Survival Rate

Card 3 — Synthesis: oxygen throughout preservation in DCD kidneys looks protective on secondary outcomes; oxygen only at the end, in ECD kidneys, does nothing

Study: Synthesis

Population: Two European randomised trials: COMPARE (106 transplanted DCD kidney pairs, oxygenated vs standard perfusion throughout) and Husen 2021 (262 transplanted expanded-criteria kidneys, brief oxygenated end-perfusion vs cold storage alone).

Summary: Synthesis: oxygen throughout preservation in DCD kidneys looks protective on secondary outcomes; oxygen only at the end, in ECD kidneys, does nothing

Result: COMPARE primary outcome (12-month eGFR): 50.5 vs 46.7 mL/min/1.73 m2, p=0.12. COMPARE graft failure: 3% vs 10% (HR 0.27, 95% CI 0.07 to 0.95). Husen 1-year graft survival: 92.1% vs 93.3% (P=.71), delayed graft function not significantly different. SPLIT, Tier C flagged because the positive half rests on secondary outcomes of a single trial.

Watch out: The two trials differ in donor type, timing, and comparator, so the split may reflect those differences rather than oxygen itself; neither trial showed a significant delayed-graft-function benefit in its record.

Source: Synthesis of Jochmans I et al. Lancet. 2020 (PMID: 33220737); Husen P et al. JAMA Surgery. 2021 (PMID: 33881456).