SourceMed · Shelf #3212 in the ask interface
Higher dialysis dose and high-flux membranes (HEMO; MPO): no survival benefit overall in 2,584 randomised patients — the only signal is high-flux in patients with albumin at most 4 g/dL
Shelf #3212 · Kidney, fluids & electrolytes
POSSIBLE (the treatment made no difference) — HEMO: death RR 0.96 for dose and 0.92 for flux, both non-significant, secondaries null; MPO: no overall survival difference, high-flux benefit only in the albumin ≤4 g/dL subgroup
Stamped: 2026-11-28.
Evidence published: 2002–2009.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In maintenance haemodialysis, does a higher dialysis dose or a high-flux membrane reduce death and hospitalisation compared with a standard dose and low-flux membrane?
Balance of the evidence
POSSIBLE (the treatment made no difference) — the two definitive randomised trials agree on the main question. In the HEMO Study (Eknoyan G et al., PMID: 12490682), 1,846 patients on thrice-weekly dialysis were randomised in a two-by-two factorial design to standard or high dialysis dose and low-flux or high-flux dialyser: the relative risk of death was 0.96 (95% CI, 0.84 to 1.10; P=0.53) for high versus standard dose and 0.92 (95% CI, 0.81 to 1.05; P=0.23) for high-flux versus low-flux, and none of the main secondary outcomes (cardiac hospitalisation or death, infection hospitalisation or death, albumin fall or death, all hospitalisations) differed significantly. In the MPO study (Locatelli F et al., PMID: 19092122), 738 incident patients randomised to high-flux or low-flux membranes and followed for 3 to 7.5 years showed no significant survival difference overall, but patients with serum albumin at most 4 g/dl had significantly higher survival with high-flux membranes (P=0.032), with a secondary signal in patients with diabetes. POSSIBLE (the treatment made no difference): pushing dose above standard targets, or switching flux, does not reduce death or hospitalisation for the average maintenance haemodialysis patient; the low-albumin high-flux signal is a subgroup finding, not a general rule.
MeSH: Adult · Aged · Female · Hemodialysis Solutions/administration & dosage · Hospitalization · Humans · Kidney Failure, Chronic/metabolism/mortality/therapy · Male · Membranes, Artificial · Middle Aged · Proportional Hazards Models · Renal Dialysis/instrumentation/methods · Survival Analysis · Urea/metabolism
Cards (3)
Card 1 — Eknoyan 2002 (HEMO): death RR 0.96 (95% CI 0.84–1.10) for high dose and 0.92 (0.81–1.05) for high-flux — every main secondary outcome also null, in 1,846 patients
Study: Randomised two-by-two factorial trial (Eknoyan 2002, HEMO Study)
Population: 1,846 patients undergoing thrice-weekly maintenance haemodialysis, randomised to standard or high dialysis dose (achieved single-pool Kt/V 1.32 versus 1.71; urea-reduction ratio 66.3% versus 75.2%) and to low-flux or high-flux dialyser (beta2-microglobulin clearance 3 versus 34 ml per minute).
Summary: Eknoyan 2002 (HEMO): death RR 0.96 (95% CI 0.84–1.10) for high dose and 0.92 (0.81–1.05) for high-flux — every main secondary outcome also null, in 1,846 patients
Result: The primary outcome, death from any cause, was not significantly influenced by dose or flux: relative risk of death 0.96 (95% CI, 0.84 to 1.10; P=0.53) for high versus standard dose, and 0.92 (95% CI, 0.81 to 1.05; P=0.23) for high-flux versus low-flux. The main secondary outcomes — first hospitalisation for cardiac causes or death, first hospitalisation for infection or death, first 15% decrease in serum albumin or death, and all hospitalisations not related to vascular access — also did not differ significantly between dose or flux groups. Possible benefits were suggested in two of seven prespecified subgroups.
Watch out: HEMO tested dose above an already-adequate standard (Kt/V 1.32) — it does not say dialysis dose doesn't matter below adequacy. The trial predates widespread convective therapies, which are a different intervention from high-flux diffusive dialysis.
Source: Eknoyan G et al. Effect of dialysis dose and membrane flux in maintenance hemodialysis. New England Journal of Medicine. 2002. PMID: 12490682. MeSH: Adult · Aged · Female · Hemodialysis Solutions/administration & dosage · Hospitalization · Humans · Kidney Failure, Chronic/metabolism/mortality/therapy · Male · Membranes, Artificial · Middle Aged · Proportional Hazards Models · Renal Dialysis/instrumentation/methods · Survival Analysis · Urea/metabolism
Card 2 — Locatelli 2009 (MPO): no survival difference for high-flux versus low-flux overall in 738 incident patients — significant benefit confined to albumin at most 4 g/dl (P=0.032)
Study: Randomised prospective trial (Locatelli 2009, MPO Study)
Population: 738 incident haemodialysis patients in Europe, stratified by serum albumin (at most 4 versus above 4 g/dl) and assigned to low-flux or high-flux membranes, followed for 3 to 7.5 years.
Summary: Locatelli 2009 (MPO): no survival difference for high-flux versus low-flux overall in 738 incident patients — significant benefit confined to albumin at most 4 g/dl (P=0.032)
Result: Kaplan-Meier survival analysis showed no significant difference between high-flux and low-flux membranes overall, and a Cox proportional hazards model concurred. Patients with serum albumin at most 4 g/dl had significantly higher survival rates in the high-flux group compared with the low-flux group (P=0.032). A secondary analysis suggested high-flux membranes may significantly improve survival of patients with diabetes.
Watch out: The positive findings are subgroup and secondary analyses of an overall-null trial — hypothesis-generating by the authors' own framing ('requires confirmation given the post hoc nature'). The abstract reports no absolute survival rates, so the size of the subgroup benefit cannot be quantified from the record.
Source: Locatelli F et al. Effect of membrane permeability on survival of hemodialysis patients. Journal of the American Society of Nephrology. 2009. PMID: 19092122. MeSH: Aged · Diabetic Nephropathies/blood/mortality/therapy · Europe/epidemiology · Female · Humans · Kaplan-Meier Estimate · Kidney Failure, Chronic/blood/mortality/therapy · Kidneys, Artificial · Male · Membranes, Artificial · Middle Aged · Permeability · Proportional Hazards Models · Prospective Studies · Renal Dialysis/methods/mortality
Card 3 — Synthesis: two large trials, one answer for the average patient — standard dose and either flux; a low-albumin subgroup signal stands unconfirmed
Study: Synthesis
Population: HEMO (1,846 prevalent patients, dose × flux factorial) and MPO (738 incident patients, flux), totalling 2,584 randomised maintenance haemodialysis patients.
Summary: Synthesis: two large trials, one answer for the average patient — standard dose and either flux; a low-albumin subgroup signal stands unconfirmed
Result: Death: RR 0.96 (dose) and 0.92 (flux) in HEMO, both non-significant; hospitalisation composites null. MPO overall survival: no significant difference; albumin at most 4 g/dl subgroup: P=0.032 in favour of high-flux. POSSIBLE (the treatment made no difference), Tier C not set: two large concordant randomised trials.
Watch out: Both trials are old enough that dialyser technology and practice have moved on; the shelf answers the dose-and-flux question as randomised, not whether modern high-volume haemodiafiltration helps — a separate question with its own trials.
Source: Synthesis of Eknoyan G et al. New England Journal of Medicine. 2002 (PMID: 12490682); Locatelli F et al. Journal of the American Society of Nephrology. 2009 (PMID: 19092122).