SourceMed · Shelf #3219 in the ask interface

Taurolidine–citrate catheter locks: pooled citrate-lock data favour antimicrobial locks for bloodstream infection, but the one double-blind taurolidine trial missed its primary endpoint and doubled thrombolytic use

Shelf #3219 · Kidney, fluids & electrolytes

SPLIT — pooled citrate-lock meta-analysis favours antimicrobial locks (CRBSI RR 0.39), but the double-blind taurolidine-citrate RCT was null for all-cause bacteraemia (HR 0.66, NS) with more thrombolytic therapy (HR 2.5)

Stamped: 2026-11-28.

Evidence published: 2004–2014.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In haemodialysis patients with central venous catheters, does a taurolidine–citrate lock reduce catheter-related bloodstream infection compared with a heparin lock?

Balance of the evidence

SPLIT — the pooled and the best-blinded evidence point in different directions. The double-blind randomised trial by Solomon LR et al. (PMID: 20207458) assigned 110 haemodialysis patients with new tunneled catheters to taurolidine-citrate or heparin locks: there were 11 bacteraemic episodes on taurolidine-citrate versus 23 on heparin (1.4 versus 2.4 episodes per 1,000 patient-days; P=0.1), no significant benefit for time to first bacteraemia (hazard ratio 0.66; 95% CI, 0.2 to 1.6; P=0.4), fewer Gram-negative infections (0.2 versus 1.1 per 1,000 patient-days; P=0.02) but no difference for Gram-positive organisms — and a greater need for thrombolytic therapy (hazard ratio 2.5; 95% CI, 1.3 to 5.2; P=0.008). The smaller randomised trial by Betjes MG et al. (PMID: 14993498), covering 76 catheters in 58 patients, found catheter colonisation and exit-site infections similar between locks, with four cases of catheter-related sepsis on heparin versus none on citrate-taurolidine, a difference the record does not show to be statistically significant. The meta-analysis by Zhao Y et al. (PMID: 24125729) of 13 citrate-lock trials (1,770 patients) found citrate locks reduced catheter-related bloodstream infection overall (risk ratio 0.39; 95% CI, 0.27 to 0.56), with the advantage confined to antimicrobial-containing citrate locks (including citrate plus taurolidine) rather than citrate alone. SPLIT: antimicrobial citrate locks probably reduce catheter-related bloodstream infection on pooled evidence, but taurolidine-citrate's own double-blind trial was null on its primary endpoint and cost more thrombolytic use.

MeSH: Adult · Aged · Anti-Infective Agents/therapeutic use · Anticoagulants/therapeutic use · Bacteremia/epidemiology/etiology/prevention & control · Catheters, Indwelling/microbiology · Citric Acid/therapeutic use · Double-Blind Method · Female · Gram-Positive Bacterial Infections/epidemiology/etiology/prevention & control · Heparin/therapeutic use · Humans · Incidence · Kidney Failure, Chronic/therapy · Male · Middle Aged · Renal Dialysis/adverse effects/instrumentation/methods · Taurine/analogs & derivatives/therapeutic use · Thiadiazines/therapeutic use

Cards (4)

Card 1 — Solomon 2010 (double-blind RCT): bacteraemia 1.4 vs 2.4 episodes per 1,000 patient-days (P=0.1); time to first bacteraemia HR 0.66 (NS); thrombolytic therapy HR 2.5 (P=0.008)

Study: Randomised double-blind controlled trial (Solomon 2010)

Population: 110 adult haemodialysis patients with tunneled cuffed intravascular catheters inserted at three centres in Northwest England, randomised at catheter insertion to interdialytic locking with taurolidine-citrate (1.35% taurolidine and 4% citrate) or heparin (5,000 U/mL). Primary endpoints: time to first bacteraemia episode from any cause and time to first thrombolytic therapy.

Summary: Solomon 2010 (double-blind RCT): bacteraemia 1.4 vs 2.4 episodes per 1,000 patient-days (P=0.1); time to first bacteraemia HR 0.66 (NS); thrombolytic therapy HR 2.5 (P=0.008)

Result: There were 11 bacteraemic episodes in the taurolidine-citrate group and 23 in the heparin group (1.4 and 2.4 episodes per 1,000 patient-days respectively; P=0.1). There was no significant benefit for time to first bacteraemia (hazard ratio 0.66; 95% CI, 0.2 to 1.6; P=0.4). Taurolidine-citrate was associated with fewer Gram-negative infections (0.2 vs 1.1 infections per 1,000 patient-days; P=0.02) but no difference for Gram-positive organisms (1.1 vs 1.2 per 1,000 patient-days; P=0.8). The need for thrombolytic therapy was greater with taurolidine-citrate (hazard ratio 2.5; 95% CI, 1.3 to 5.2; P=0.008). The authors note the small sample size and that bacteraemia from all causes, not only catheter-related, was counted.

Watch out: The trial counted all-cause bacteraemia, diluting any catheter-specific effect, and was small; but it is the only double-blind test of this exact lock, and its primary endpoint was missed while its harm endpoint (thrombolytics) was hit.

Source: Solomon LR et al. A randomized double-blind controlled trial of taurolidine-citrate catheter locks for the prevention of bacteremia in patients treated with hemodialysis. American Journal of Kidney Diseases. 2010. PMID: 20207458. Registry ID: ISRCTN51902376. MeSH: Adult · Aged · Anti-Infective Agents/therapeutic use · Anticoagulants/therapeutic use · Bacteremia/epidemiology/etiology/prevention & control · Catheters, Indwelling/microbiology · Citric Acid/therapeutic use · Double-Blind Method · Female · Gram-Positive Bacterial Infections/epidemiology/etiology/prevention & control · Heparin/therapeutic use · Humans · Incidence · Kidney Failure, Chronic/therapy · Male · Middle Aged · Renal Dialysis/adverse effects/instrumentation/methods · Taurine/analogs & derivatives/therapeutic use · Thiadiazines/therapeutic use

Card 2 — Betjes 2004: 76 catheters — colonisation and exit-site infections similar; catheter-related sepsis four cases on heparin versus none on citrate-taurolidine

Study: Randomised prospective trial (Betjes 2004)

Population: 58 patients receiving a dialysis catheter (76 catheters in total), randomised to catheter locking with heparin or a citrate-taurolidine-containing solution, with routine catheter-lumen blood cultures every two weeks and at removal, and registration of catheter-related sepsis and exit-site infections.

Summary: Betjes 2004: 76 catheters — colonisation and exit-site infections similar; catheter-related sepsis four cases on heparin versus none on citrate-taurolidine

Result: The incidence of catheter colonisation progressed slowly over time with no differences between heparin and citrate-taurolidine catheters, and exit-site infections were also similar. In the heparin group, four cases of catheter-related sepsis occurred, as opposed to no sepsis episodes in patients whose catheters were locked with the citrate-taurolidine solution; the record reports this as P<0.5, i.e. not statistically significant. No side effects with the citrate-taurolidine lock were noted.

Watch out: Seventy-six catheters and four events in one arm: the sepsis contrast that makes this trial look positive is a 4-versus-0 split in a small unblinded study, and its own colonisation endpoint — the mechanism the lock is supposed to interrupt — showed no difference.

Source: Betjes MG et al. Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution. Nephrology Dialysis Transplantation. 2004. PMID: 14993498. MeSH: Anti-Infective Agents/administration & dosage · Bacterial Infections/etiology/prevention & control · Catheterization, Central Venous/adverse effects · Catheters, Indwelling · Citric Acid/administration & dosage · Equipment Contamination/prevention & control · Female · Humans · Male · Middle Aged · Prospective Studies · Renal Dialysis/instrumentation · Sepsis/etiology/prevention & control · Solutions · Taurine/administration & dosage/analogs & derivatives · Thiadiazines/administration & dosage

Card 3 — Zhao 2014 meta-analysis: citrate locks cut CRBSI (RR 0.39; 95% CI 0.27 to 0.56) across 13 RCTs — but the benefit sits in antimicrobial-containing locks, not citrate alone

Study: Systematic review and meta-analysis of RCTs (Zhao 2014)

Population: 13 randomised controlled trials (1,770 patients, 221,064 catheter-days) comparing citrate locks with heparin locks in haemodialysis patients with central venous catheters.

Summary: Zhao 2014 meta-analysis: citrate locks cut CRBSI (RR 0.39; 95% CI 0.27 to 0.56) across 13 RCTs — but the benefit sits in antimicrobial-containing locks, not citrate alone

Result: Citrate locks significantly reduced catheter-related bloodstream infection (risk ratio 0.39; 95% CI, 0.27 to 0.56; P<0.001). In subgroup analysis, antimicrobial-containing citrate locks (citrate plus gentamicin, citrate plus taurolidine, and citrate plus methylene blue/parabens) were superior to heparin for preventing CRBSI, whereas citrate alone was not (P=0.2). Bleeding episodes were fewer with citrate locks (risk ratio 0.48; 95% CI, 0.30 to 0.76; P=0.002); exit-site infection, catheter removal for poor flow, thrombolytic treatment, thrombosis, and all-cause death did not differ. All included studies were performed in Western countries.

Watch out: The pooled estimate mixes different antimicrobial partners (an antibiotic, taurolidine, a dye combination) and mostly open-label trials; attributing the pooled benefit to taurolidine specifically goes beyond what the subgroup analysis can separate.

Source: Zhao Y et al. Citrate versus heparin lock for hemodialysis catheters: a systematic review and meta-analysis of randomized controlled trials. American Journal of Kidney Diseases. 2014. PMID: 24125729. MeSH: Anticoagulants/pharmacology · Catheter-Related Infections/prevention & control · Central Venous Catheters/standards · Citric Acid/pharmacology · Heparin/pharmacology · Humans · Randomized Controlled Trials as Topic/methods · Renal Dialysis/methods · Thrombosis/prevention & control

Card 4 — Synthesis: class-level pooled benefit, product-level double-blind null — the honest shelf is a split

Study: Synthesis

Population: Two randomised taurolidine-citrate trials (110 and 58 patients) and a 13-trial meta-analysis of citrate-based locks (1,770 patients).

Summary: Synthesis: class-level pooled benefit, product-level double-blind null — the honest shelf is a split

Result: Taurolidine-citrate double-blind RCT: bacteraemia HR 0.66 (95% CI 0.2 to 1.6), episodes 1.4 vs 2.4 per 1,000 patient-days (P=0.1); thrombolytic HR 2.5 (P=0.008). Small RCT: sepsis 0 vs 4 cases, not significant. Citrate-lock meta-analysis: CRBSI risk ratio 0.39 (95% CI 0.27 to 0.56), driven by antimicrobial-containing locks. SPLIT, Tier C not set: randomised and meta-analytic evidence both exist but conflict at the level of the named product.

Watch out: Catheter care bundles and exit-site practice changed substantially over the decades these trials span; absolute infection rates from older trials overstate what a lock can add in a modern unit.

Source: Synthesis of Solomon LR et al. American Journal of Kidney Diseases. 2010 (PMID: 20207458); Betjes MG et al. Nephrology Dialysis Transplantation. 2004 (PMID: 14993498); Zhao Y et al. American Journal of Kidney Diseases. 2014 (PMID: 24125729).