SourceMed · Shelf #3304 in the ask interface
Interatrial shunt for heart failure with preserved ejection fraction: it lowered exercise wedge pressure in a 44-patient phase 2 trial — then the 626-patient sham-controlled trial found no fewer heart-failure events and no better health status
Shelf #3304 · Heart, vessels, blood pressure & clotting
SPLIT — exercise wedge pressure reduced in phase 2; no benefit on heart-failure events or health status in the phase 3 sham-controlled trial
Stamped: 2026-11-28.
Evidence published: 2018–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In heart failure with preserved or mildly reduced ejection fraction and raised left atrial pressure, does an interatrial shunt device improve symptoms and outcomes compared with sham?
Balance of the evidence
SPLIT — the mechanism works and the clinical benefit does not follow. In the phase 2 REDUCE LAP-HF I trial (Feldman T et al., PMID: 29142012), 44 patients with ejection fraction ≥40% and exercise wedge pressure ≥25 mm Hg were randomised to the Corvia interatrial shunt device or sham: at 1 month the device produced a greater reduction in exercise pulmonary capillary wedge pressure (P=0.028 across exercise stages; peak wedge fell 3.5 ± 6.4 versus 0.5 ± 5.0 mm Hg, P=0.14). In the phase 3 REDUCE LAP-HF II trial (Shah SJ et al., PMID: 35120593), 626 patients were randomised to the device or sham: the hierarchical primary endpoint was exactly neutral (win ratio 1.0, 95% CI 0.8 to 1.2; p=0.85), no component differed, and the composite safety endpoint occurred in 38% on the device versus 31% on sham (p=0.11). Prespecified subgroups with high exercise pulmonary artery pressure, large right atria, and men fared worse on heart-failure events with the device. SPLIT: a real haemodynamic effect in phase 2; no reduction in heart-failure events or improvement in health status in the definitive sham-controlled trial.
MeSH: Adult · Cardiac Catheterization/instrumentation · Flavins · Heart Atria/surgery · Heart Failure/physiopathology · Humans · Luciferases · Male · Stroke Volume
Cards (3)
Card 1 — REDUCE LAP-HF I (Feldman 2018): exercise wedge pressure fell more with the shunt at 1 month (P=0.028 across stages) in 44 randomised patients
Study: Randomised sham-controlled phase 2 trial (Feldman 2018, REDUCE LAP-HF I)
Population: 44 patients (mean age 70 ± 9 years, 50% women) with NYHA class III or ambulatory class IV heart failure, ejection fraction ≥40%, exercise pulmonary capillary wedge pressure ≥25 mm Hg and a wedge-to-right-atrial gradient ≥5 mm Hg, randomised 1:1 to the Corvia interatrial shunt device or a sham procedure (venous access and intracardiac echo, no device); patients and follow-up assessors blinded.
Summary: REDUCE LAP-HF I (Feldman 2018): exercise wedge pressure fell more with the shunt at 1 month (P=0.028 across stages) in 44 randomised patients
Result: At 1 month, the shunt produced a greater reduction in exercise pulmonary capillary wedge pressure than sham across all exercise stages (P=0.028); peak wedge pressure fell by 3.5 ± 6.4 mm Hg with the device versus 0.5 ± 5.0 mm Hg with sham (P=0.14). There were no peri-procedural or 1-month major adverse cardiac, cerebrovascular or renal events in the device group and one event (worsening renal function) in the control group.
Watch out: Forty-four patients and a 1-month haemodynamic endpoint: this trial could only ever show the device does what it is engineered to do. The peak-pressure comparison itself was not significant (P=0.14); the positive P value comes from the repeated-measures model across exercise stages.
Source: Feldman T et al. Transcatheter Interatrial Shunt Device for the Treatment of Heart Failure With Preserved Ejection Fraction (REDUCE LAP-HF I [Reduce Elevated Left Atrial Pressure in Patients With Heart Failure]): A Phase 2, Randomized, Sham-Controlled Trial. Circulation. 2018. PMID: 29142012. Registry ID: NCT02600234. MeSH: Aged · Atrial Function, Left · Atrial Pressure · Australia · Cardiac Catheterization/adverse effects/instrumentation · Cardiac Catheters · Europe · Exercise Tolerance · Female · Heart Failure/diagnosis/physiopathology/therapy · Heart-Assist Devices · Humans · Male · Middle Aged · Prospective Studies · Prosthesis Design · Pulmonary Wedge Pressure · Recovery of Function · Stroke Volume · Time Factors · Treatment Outcome · United States · Ventricular Function, Left
Card 2 — REDUCE LAP-HF II (Shah 2022): primary composite win ratio 1.0 (0.8–1.2), p=0.85; safety events 38% vs 31% — in 626 patients
Study: Randomised blinded sham-controlled trial (Shah 2022, REDUCE LAP-HF II)
Population: 626 patients aged ≥40 years with symptomatic heart failure, ejection fraction ≥40% and exercise pulmonary capillary wedge pressure ≥25 mm Hg exceeding right atrial pressure by ≥5 mm Hg, at 89 centres, randomised 1:1 to the Corvia atrial shunt device (n = 314) or sham procedure (n = 312); patients and outcome assessors masked.
Summary: REDUCE LAP-HF II (Shah 2022): primary composite win ratio 1.0 (0.8–1.2), p=0.85; safety events 38% vs 31% — in 626 patients
Result: There was no difference in the hierarchical primary endpoint — cardiovascular death or non-fatal ischaemic stroke at 12 months, total heart-failure events to 24 months, and change in Kansas City Cardiomyopathy Questionnaire score at 12 months (win ratio 1.0, 95% CI 0.8 to 1.2; p=0.85) — nor in any individual component. The composite safety endpoint occurred in 116 (38%) device patients versus 97 (31%) sham patients (p=0.11). Prespecified subgroups showed worse heart-failure-event outcomes with the device at high exercise pulmonary artery systolic pressure (>70 mm Hg at 20 W), larger right atrial volume index (≥29.7 mL/m²), and in men.
Watch out: The neutral average conceals prespecified harm-leaning subgroups — patients with latent pulmonary vascular disease may be hurt by a left-to-right shunt — so the result is not 'the device does nothing' but 'no benefit overall, possible harm where pulmonary pressures run high'. Enrolment required an invasive exercise-haemodynamic phenotype that routine practice rarely measures.
Source: Shah SJ et al. Atrial shunt device for heart failure with preserved and mildly reduced ejection fraction (REDUCE LAP-HF II): a randomised, multicentre, blinded, sham-controlled trial. Lancet. 2022. PMID: 35120593. Registry ID: NCT03088033. MeSH: Adult · Cardiac Catheterization/instrumentation · Flavins · Heart Atria/surgery · Heart Failure/physiopathology · Humans · Luciferases · Male · Stroke Volume
Card 3 — Synthesis: a clean mechanistic win that did not convert — wedge pressure down, events and symptoms unchanged at scale
Study: Synthesis
Population: Two randomised sham-controlled trials of the Corvia interatrial shunt device in heart failure with ejection fraction ≥40% and raised exercise wedge pressure: phase 2 (n = 44, 1-month haemodynamics) and phase 3 (n = 626, events and health status to 24 months).
Summary: Synthesis: a clean mechanistic win that did not convert — wedge pressure down, events and symptoms unchanged at scale
Result: Phase 2: greater exercise wedge-pressure reduction with the device (P=0.028 across stages). Phase 3: primary composite win ratio 1.0 (95% CI 0.8 to 1.2); safety composite 38% vs 31%. SPLIT — surrogate positive, clinical outcomes neutral, with harm-leaning subgroups on the face of the phase 3 card.
Watch out: Both trials come from one device programme with one sponsor; no independent replication exists. Tier C is not set: the clinical null rests on a large blinded sham-controlled trial.
Source: Synthesis of Shah SJ et al. Lancet. 2022 (PMID: 35120593), Feldman T et al. Circulation. 2018 (PMID: 29142012).