Ablation for persistent atrial fibrillation with unexplained cardiomyopathy: ejection fraction rose 18 points versus 4 with rate control in a 68-patient trial — a large effect on a surrogate endpoint, in a small, carefully selected group

Shelf #3316 · Heart, vessels, blood pressure & clotting

POSSIBLE (benefit) — one small randomised trial with a large ejection-fraction effect, supported by a small meta-analysis; no hard-outcome data

Stamped: 2026-11-28.

Evidence published: 2016–2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In persistent atrial fibrillation with reduced ejection fraction and suspected tachycardia-induced cardiomyopathy, does catheter ablation improve ejection fraction compared with medical rate control?

Balance of the evidence

POSSIBLE (benefit) — the effect is large, mechanistically coherent, and rests on very few patients. In CAMERA-MRI (Prabhu S et al., PMID: 28855115), 68 patients with persistent atrial fibrillation and idiopathic cardiomyopathy (ejection fraction ≤45%) were randomised to catheter ablation or continued medical rate control: at 6 months, ejection fraction had improved by 18 ± 13% with ablation versus 4.4 ± 13% with rate control (p < 0.0001), and normalised (≥50%) in 58% versus 9% (p = 0.0002), with post-ablation AF burden of 1.6 ± 5.0%; patients without ventricular fibrosis on MRI improved most. The earlier meta-analysis of ablation versus rate control in persistent AF with heart failure (Zhu M et al., PMID: 27472728) pooled just 3 randomised trials and 143 patients, finding an ejection-fraction advantage of 6.22% (95% CI 0.7 to 11.74; P = 0.03) and better peak oxygen consumption and NYHA class. POSSIBLE (benefit): in AF with unexplained cardiomyopathy, restoring sinus rhythm by ablation recovers ventricular function far more than rate control — on surrogate endpoints, in small selected trials, with no mortality or hospitalisation data.

MeSH: Aged · Atrial Fibrillation/diagnostic imaging/epidemiology/therapy · Catheter Ablation/methods/trends · Electrocardiography, Ambulatory/methods/trends · Female · Gadolinium/administration & dosage · Humans · Magnetic Resonance Imaging, Cine/methods/trends · Male · Middle Aged · Prospective Studies · Single-Blind Method · Ventricular Dysfunction, Left/diagnostic imaging/epidemiology/therapy

Cards (3)

Card 1 — CAMERA-MRI (Prabhu 2017): ejection fraction +18 ± 13% with ablation vs +4.4 ± 13% with rate control at 6 months (p < 0.0001); normalisation 58% vs 9%

Study: Randomised trial (Prabhu 2017, CAMERA-MRI)

Population: 68 patients (33 per arm after 2 dropouts, from 301 screened) with persistent atrial fibrillation and idiopathic cardiomyopathy (ejection fraction ≤45%, no other cause found), rate control optimised first, cardiac MRI before randomisation to catheter ablation (pulmonary vein plus posterior wall isolation) or ongoing medical rate control; AF burden by implanted loop recorder; primary endpoint change in ejection fraction on repeat MRI at 6 months.

Summary: CAMERA-MRI (Prabhu 2017): ejection fraction +18 ± 13% with ablation vs +4.4 ± 13% with rate control at 6 months (p < 0.0001); normalisation 58% vs 9%

Result: Absolute ejection fraction improved by 18 ± 13% in the ablation group versus 4.4 ± 13% in the rate-control group (p < 0.0001) and normalised (≥50%) in 58% versus 9% (p = 0.0002). Mean AF burden after ablation was 1.6 ± 5.0% at 6 months. In ablated patients, absence of late gadolinium enhancement (fibrosis) predicted greater ejection-fraction improvement (10.7% greater; p = 0.0069) and normalisation (73% vs 29%; p = 0.0093).

Watch out: Sixty-eight patients, a 6-month imaging endpoint, and a population screened down from 301 to find unexplained cardiomyopathy — the 18-point gain describes the reversible, tachycardia-mediated end of the AF–heart-failure spectrum, not AF with scarred ventricles, where the fibrosis subgroup already shows the effect shrinking. Single-blind, no sham procedure, no clinical-event endpoints.

Source: Prabhu S et al. Catheter Ablation Versus Medical Rate Control in Atrial Fibrillation and Systolic Dysfunction: The CAMERA-MRI Study. Journal of the American College of Cardiology. 2017. PMID: 28855115. Registry ID: ACTRN12613000880741. MeSH: Aged · Atrial Fibrillation/diagnostic imaging/epidemiology/therapy · Catheter Ablation/methods/trends · Electrocardiography, Ambulatory/methods/trends · Female · Gadolinium/administration & dosage · Humans · Magnetic Resonance Imaging, Cine/methods/trends · Male · Middle Aged · Prospective Studies · Single-Blind Method · Ventricular Dysfunction, Left/diagnostic imaging/epidemiology/therapy

Card 2 — Zhu 2016 meta-analysis: 3 randomised trials, 143 patients — ejection fraction +6.22% (0.7 to 11.74) with ablation over rate control; peak VO₂ and NYHA also better

Study: Systematic review and meta-analysis of randomised trials (Zhu 2016)

Population: 3 randomised controlled trials totalling 143 patients with persistent atrial fibrillation, heart failure and left ventricular systolic dysfunction, comparing catheter ablation with medical rate control; endpoints included ejection fraction, NYHA class, BNP, peak oxygen consumption, 6-minute walk and quality of life.

Summary: Zhu 2016 meta-analysis: 3 randomised trials, 143 patients — ejection fraction +6.22% (0.7 to 11.74) with ablation over rate control; peak VO₂ and NYHA also better

Result: Catheter ablation improved ejection fraction more than rate control (mean difference 6.22%, 95% CI 0.7 to 11.74; P = 0.03), improved peak oxygen consumption (mean difference 2.81 mL/kg/min, 95% CI 0.78 to 4.85; P = 0.007), reduced NYHA class (mean difference 0.9, 95% CI 0.59 to 1.21; P < 0.001) and improved Minnesota Living with Heart Failure scores (mean difference -11.05, 95% CI -19.45 to -2.66; P = 0.01). BNP, 6-minute walk and SF-36 differences favoured ablation without reaching significance.

Watch out: Three small trials and 143 patients in total, all pre-dating CAMERA-MRI — the pooled ejection-fraction confidence interval (0.7 to 11.74) barely excludes no effect. It corroborates direction, not size, and shares the same surrogate-endpoint limitation as the trial it supports.

Source: Zhu M et al. Catheter ablation versus medical rate control for persistent atrial fibrillation in patients with heart failure: A PRISMA-compliant systematic review and meta-analysis of randomized controlled trials. Medicine. 2016. PMID: 27472728. MeSH: Anti-Arrhythmia Agents/therapeutic use · Atrial Fibrillation/therapy · Catheter Ablation · Heart Failure/therapy · Humans · Patient Safety · Randomized Controlled Trials as Topic · Treatment Outcome

Card 3 — Synthesis: where the cardiomyopathy is the arrhythmia, removing the arrhythmia recovers the ventricle — proven for ejection fraction, unproven for events

Study: Synthesis

Population: CAMERA-MRI (68 patients with persistent AF and idiopathic cardiomyopathy) plus a meta-analysis of 3 earlier randomised trials (143 patients with persistent AF and heart failure) of catheter ablation versus medical rate control.

Summary: Synthesis: where the cardiomyopathy is the arrhythmia, removing the arrhythmia recovers the ventricle — proven for ejection fraction, unproven for events

Result: Ejection fraction: +18 ± 13% vs +4.4 ± 13% (CAMERA-MRI); pooled +6.22% (meta-analysis). Normalisation of ejection fraction: 58% vs 9% (CAMERA-MRI). No mortality, hospitalisation or stroke data in either source. POSSIBLE (benefit), Tier C — a single small trial carries the headline effect on a surrogate endpoint.

Watch out: Patients whose ventricular dysfunction has another cause, or extensive fibrosis, are outside the proven benefit; generalising the 18-point figure to all AF with low ejection fraction would overstate the evidence severalfold. Larger trials in broader AF–heart-failure populations ask a related but different question and are not carded here.

Source: Synthesis of Prabhu S et al. Journal of the American College of Cardiology. 2017 (PMID: 28855115), Zhu M et al. Medicine. 2016 (PMID: 27472728).