Adding linear lesions or fractionated-signal ablation to pulmonary vein isolation in persistent atrial fibrillation: STAR AF II found no fewer recurrences (freedom 59% with isolation alone vs 49% and 46% with more ablation) — only longer procedures

Shelf #3318 · Heart, vessels, blood pressure & clotting

LIKELY (the treatment made no difference) — the definitive randomised trial and a concordant meta-analysis both show no arrhythmia benefit from adjunctive substrate ablation

Stamped: 2026-11-28.

Evidence published: 2015–2016.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In persistent atrial fibrillation, does adding linear lesions or ablation of complex fractionated signals to pulmonary vein isolation improve freedom from arrhythmia?

Balance of the evidence

LIKELY (the treatment made no difference) — the definitive trial and the pooled literature point the same way. In STAR AF II (Verma A et al., PMID: 25946280), 589 patients with persistent atrial fibrillation were randomised to pulmonary vein isolation alone (n = 67), isolation plus ablation of complex fractionated electrograms (n = 263), or isolation plus linear ablation (n = 259): after 18 months, freedom from recurrent atrial fibrillation was 59% with isolation alone versus 49% and 46% with the adjunctive strategies (P=0.15), with no differences in secondary endpoints, and procedure time was significantly shorter with isolation alone (P<0.001). The meta-analysis of adjunctive strategies (Scott PA et al., PMID: 26559915) pooled 10 studies and 1,821 patients: adding fractionated-electrogram ablation (risk ratio 0.86, 95% CI 0.64 to 1.16; P = 0.32) or linear ablation (RR 0.64, 95% CI 0.37 to 1.09; P = 0.10) did not significantly improve arrhythmia-free survival, while increasing procedure and fluoroscopy times. LIKELY (the treatment made no difference): in persistent AF, more ablation is not better ablation — pulmonary vein isolation alone remains the benchmark these strategies failed to beat.

MeSH: Aged · Atrial Fibrillation/surgery · Catheter Ablation/adverse effects/methods · Disease-Free Survival · Electrocardiography · Female · Heart Atria/surgery · Humans · Kaplan-Meier Estimate · Male · Middle Aged · Mitral Valve/surgery · Operative Time · Proportional Hazards Models · Pulmonary Veins · Recurrence · Secondary Prevention · Stroke Volume

Cards (3)

Card 1 — STAR AF II (Verma 2015): freedom from AF at 18 months 59% (isolation alone) vs 49% (plus fractionated-electrogram ablation) vs 46% (plus linear ablation), P=0.15 — in 589 patients

Study: Randomised controlled trial (Verma 2015, STAR AF II)

Population: 589 patients with persistent atrial fibrillation randomised 1:4:4 to pulmonary vein isolation alone (67), isolation plus ablation of electrograms showing complex fractionated activity (263), or isolation plus additional linear ablation across the left atrial roof and mitral isthmus (259); follow-up 18 months; primary endpoint freedom from documented AF recurrence >30 seconds after a single procedure.

Summary: STAR AF II (Verma 2015): freedom from AF at 18 months 59% (isolation alone) vs 49% (plus fractionated-electrogram ablation) vs 46% (plus linear ablation), P=0.15 — in 589 patients

Result: After 18 months, 59% of patients assigned to isolation alone were free from recurrent atrial fibrillation, versus 49% with added fractionated-electrogram ablation and 46% with added linear ablation (P=0.15). There were no significant differences in secondary endpoints, including freedom from AF after two procedures and freedom from any atrial arrhythmia. Procedure time was significantly shorter for isolation alone (P<0.001). Complications included tamponade (3 patients), stroke or transient ischaemic attack (3) and atrioesophageal fistula (1).

Watch out: The isolation-alone arm was deliberately small (67 patients, a 1:4:4 design powered around the adjunctive arms), so its 59% carries a wide interval — but the direction is consistent: both larger, more-ablated arms did numerically worse, which is the opposite of what underpowering alone would be expected to hide.

Source: Verma A et al. Approaches to catheter ablation for persistent atrial fibrillation. The New England journal of medicine. 2015. PMID: 25946280. Registry ID: NCT01203748. MeSH: Aged · Atrial Fibrillation/surgery · Catheter Ablation/adverse effects/methods · Disease-Free Survival · Electrocardiography · Female · Heart Atria/surgery · Humans · Kaplan-Meier Estimate · Male · Middle Aged · Mitral Valve/surgery · Operative Time · Proportional Hazards Models · Pulmonary Veins · Recurrence · Secondary Prevention · Stroke Volume

Card 2 — Scott 2016 meta-analysis: 10 studies, 1,821 patients — fractionated-electrogram ablation RR 0.86 (0.64–1.16); linear ablation RR 0.64 (0.37–1.09); both with longer procedures

Study: Meta-analysis (Scott 2016)

Population: 10 studies (6 of fractionated-electrogram ablation, 3 of linear ablation, 1 of both) totalling 1,821 patients with persistent atrial fibrillation, comparing pulmonary vein isolation plus an adjunctive substrate strategy against isolation-based strategies alone; randomised and non-randomised studies included.

Summary: Scott 2016 meta-analysis: 10 studies, 1,821 patients — fractionated-electrogram ablation RR 0.86 (0.64–1.16); linear ablation RR 0.64 (0.37–1.09); both with longer procedures

Result: Compared with isolation alone, adding complex fractionated electrogram ablation did not significantly improve arrhythmia-free survival (RR 0.86, 95% CI 0.64 to 1.16; P = 0.32), nor did adding left atrial linear ablation (RR 0.64, 95% CI 0.37 to 1.09; P = 0.10). Adjunctive fractionated-electrogram ablation significantly increased procedure and fluoroscopy times, with non-significant increases for linear ablation.

Watch out: The pool mixes randomised and non-randomised studies and predates full assimilation of STAR AF II-era technique; the linear-ablation point estimate (0.64) is imprecise enough to hide a real effect in either direction. It is carded as concordance for the trial, not as independent proof.

Source: Scott PA et al. The impact of adjunctive complex fractionated atrial electrogram ablation and linear lesions on outcomes in persistent atrial fibrillation: a meta-analysis. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2016. PMID: 26559915. MeSH: Action Potentials · Atrial Fibrillation/diagnosis/physiopathology/surgery · Catheter Ablation/adverse effects/methods · Chi-Square Distribution · Disease-Free Survival · Electrophysiologic Techniques, Cardiac · Fluoroscopy · Heart Rate · Humans · Odds Ratio · Operative Time · Predictive Value of Tests · Pulmonary Veins/physiopathology/surgery · Radiation Dosage · Radiation Exposure · Risk Factors · Treatment Outcome

Card 3 — Synthesis: the field tested 'more is better' properly, and more lost — isolation alone is shorter, simpler and at least as effective

Study: Synthesis

Population: STAR AF II (589 randomised patients, three ablation strategies, 18 months) and a 10-study meta-analysis of adjunctive substrate ablation in persistent atrial fibrillation (1,821 patients).

Summary: Synthesis: the field tested 'more is better' properly, and more lost — isolation alone is shorter, simpler and at least as effective

Result: STAR AF II freedom from AF: 59% vs 49% vs 46% (P=0.15). Meta-analysis: RR 0.86 (fractionated electrograms) and 0.64 (linear), neither significant; procedure and fluoroscopy times increased with adjunctive ablation. LIKELY (the treatment made no difference).

Watch out: This verdict covers the two adjunctive strategies as delivered in that era; it does not condemn every form of substrate modification (for example, imaging-guided or posterior-wall approaches tested since), which would need their own shelves. Tier C is not set: a large definitive trial plus a concordant meta-analysis.

Source: Synthesis of Verma A et al. The New England journal of medicine. 2015 (PMID: 25946280), Scott PA et al. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2016 (PMID: 26559915).