SourceMed · Shelf #3339 in the ask interface
Drug-eluting stents beat bare-metal stents even when antiplatelet therapy must be short: safety composite 9.4% vs 12.9% in high-bleeding-risk patients, major events 12% vs 16% in the over-75s — bleeding no higher in either trial
Shelf #3339 · Heart, vessels, blood pressure & clotting
LIKELY (benefit) — LEADERS FREE (n=2,466): safety composite 9.4% vs 12.9% (HR 0.71), revascularisation 5.1% vs 9.8%; SENIOR (n=1,200, age ≥75): major events 12% vs 16% (RR 0.71), bleeding 5% vs 5%
Stamped: 2026-11-28.
Evidence published: 2015–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients at high bleeding risk, do drug-eluting stents beat bare-metal stents on death, myocardial infarction, and revascularisation without excess bleeding on short dual antiplatelet therapy?
Balance of the evidence
LIKELY (benefit) — two trials, two high-risk populations, the same answer. In LEADERS FREE (Urban P et al., PMID: 26466021), 2,466 patients at high bleeding risk received a polymer-free umirolimus-coated stent or a very similar bare-metal stent, all with just one month of dual antiplatelet therapy: at 390 days the primary safety composite (cardiac death, myocardial infarction, or stent thrombosis) occurred in 9.4% on the drug-coated stent versus 12.9% on the bare-metal stent (hazard ratio 0.71, 95% CI 0.56–0.91; p=0.005 for superiority), and clinically driven target-lesion revascularisation in 5.1% versus 9.8% (HR 0.50, 0.37–0.69; p<0.001). In SENIOR (Varenne O et al., PMID: 29102362), 1,200 patients aged 75 or older received a drug-eluting or bare-metal stent with short dual therapy (one month if stable, six months if unstable): the primary composite (all-cause mortality, myocardial infarction, stroke, or ischaemia-driven target-lesion revascularisation) occurred in 12% versus 16% (relative risk 0.71, 95% CI 0.52–0.94; p=0.02), with bleeding complications no different (5% vs 5%; p=0.68) and stent thrombosis infrequent in both groups (1% vs 1%). LIKELY (benefit): with short dual antiplatelet therapy, a drug-eluting (or drug-coated) stent is both safer and more effective than a bare-metal stent in patients at high bleeding risk or of advanced age — the historical reason for choosing bare metal no longer holds.
MeSH: Aged · Combined Modality Therapy · Coronary Artery Disease/drug therapy/therapy · Double-Blind Method · Drug-Eluting Stents/adverse effects · Female · Humans · Immunosuppressive Agents/administration & dosage · Kaplan-Meier Estimate · Male · Middle Aged · Percutaneous Coronary Intervention · Platelet Aggregation Inhibitors/therapeutic use · Polymers · Prosthesis Design · Sirolimus/administration & dosage/analogs & derivatives · Stents/adverse effects
Cards (3)
Card 1 — Urban 2015 (LEADERS FREE, n=2,466, high bleeding risk, 1 month of dual therapy): safety composite 9.4% vs 12.9% (HR 0.71; p=0.005 for superiority); target-lesion revascularisation 5.1% vs 9.8%
Study: Randomised double-blind trial (Urban 2015, LEADERS FREE)
Population: 2,466 patients at high risk of bleeding undergoing PCI, assigned to a polymer-free, carrier-free umirolimus (biolimus A9) drug-coated stent or a very similar bare-metal stent; all patients received one month of dual antiplatelet therapy; follow-up to 390 days.
Summary: Urban 2015 (LEADERS FREE, n=2,466, high bleeding risk, 1 month of dual therapy): safety composite 9.4% vs 12.9% (HR 0.71; p=0.005 for superiority); target-lesion revascularisation 5.1% vs 9.8%
Result: The primary safety end point (cardiac death, myocardial infarction, or stent thrombosis) occurred in 112 patients (9.4%) in the drug-coated-stent group and 154 (12.9%) in the bare-metal-stent group (risk difference −3.6 percentage points, 95% CI −6.1 to −1.0; hazard ratio 0.71, 95% CI 0.56–0.91; p<0.001 for noninferiority and p=0.005 for superiority). Clinically driven target-lesion revascularisation was needed in 59 patients (5.1%) versus 113 (9.8%) (risk difference −4.8 points, −6.9 to −2.6; HR 0.50, 0.37–0.69; p<0.001).
Watch out: The winning device is a drug-coated stent without polymer — a specific technology, not every drug-eluting stent — and 'high bleeding risk' was defined by the trial's criteria. The result overturns the assumption that bare metal is the cautious choice when antiplatelet therapy must be short; it does not compare one month with longer dual therapy.
Source: Urban P et al. Polymer-free Drug-Coated Coronary Stents in Patients at High Bleeding Risk. New England Journal of Medicine. 2015. PMID: 26466021. Registry ID: NCT01623180. MeSH: Aged · Combined Modality Therapy · Coronary Artery Disease/drug therapy/therapy · Double-Blind Method · Drug-Eluting Stents/adverse effects · Female · Humans · Immunosuppressive Agents/administration & dosage · Kaplan-Meier Estimate · Male · Middle Aged · Percutaneous Coronary Intervention · Platelet Aggregation Inhibitors/therapeutic use · Polymers · Prosthesis Design · Sirolimus/administration & dosage/analogs & derivatives · Stents/adverse effects
Card 2 — Varenne 2018 (SENIOR, n=1,200 aged ≥75): major events 12% on DES vs 16% on BMS (RR 0.71; p=0.02); bleeding 5% vs 5%; stent thrombosis 1% vs 1%
Study: Randomised single-blind trial (Varenne 2018, SENIOR)
Population: 1,200 patients aged 75 years or older at 44 centres in nine countries, with stable angina, silent ischaemia, or an acute coronary syndrome and at least one lesion of at least 70% stenosis eligible for PCI, assigned to a drug-eluting stent (n=596) or a similar bare-metal stent (n=604); intended dual antiplatelet therapy duration (1 month if stable, 6 months if unstable) was recorded before randomisation.
Summary: Varenne 2018 (SENIOR, n=1,200 aged ≥75): major events 12% on DES vs 16% on BMS (RR 0.71; p=0.02); bleeding 5% vs 5%; stent thrombosis 1% vs 1%
Result: The primary outcome (all-cause mortality, myocardial infarction, stroke, or ischaemia-driven target-lesion revascularisation at one year) occurred in 68 patients (12%) in the DES group and 98 (16%) in the BMS group (relative risk 0.71, 95% CI 0.52–0.94; p=0.02). Bleeding complications were similar (26 [5%] vs 29 [5%]; RR 0.90, 0.51–1.54; p=0.68), and stent thrombosis was infrequent in both groups (3 [1%] vs 8 [1%]; RR 0.38; p=0.13).
Watch out: Single-blind (patients and outcome assessors masked, operators not), and the composite is carried partly by revascularisation. But its population — everyone over 75, not a bleeding-risk subset — makes it the generalisability partner to LEADERS FREE's selected high-risk cohort.
Source: Varenne O et al. Drug-eluting stents in elderly patients with coronary artery disease (SENIOR): a randomised single-blind trial. Lancet. 2018. PMID: 29102362. Registry ID: NCT02099617. MeSH: Age Factors · Aged · Aged, 80 and over · Coronary Artery Disease/therapy · Drug-Eluting Stents · Female · Humans · Male · Percutaneous Coronary Intervention · Platelet Aggregation Inhibitors/therapeutic use · Single-Blind Method · Treatment Outcome
Card 3 — Synthesis
Study: Synthesis
Population: Two randomised trials totalling 3,666 patients in whom dual antiplatelet therapy had to be short: LEADERS FREE (2,466 patients at high bleeding risk, one month of dual therapy) and SENIOR (1,200 patients aged 75 or older).
Summary: Synthesis
Result: Safety/major-event composites: 9.4% vs 12.9% (HR 0.71) and 12% vs 16% (RR 0.71). Revascularisation: 5.1% vs 9.8% in LEADERS FREE. Bleeding in SENIOR: 5% vs 5%. LIKELY (benefit) for drug-eluting/drug-coated stents over bare-metal stents in these populations.
Watch out: Tier C is not set: two large concordant randomised trials carry the shelf. The devices differ between trials (polymer-free drug-coated vs conventional drug-eluting), so the claim is about the strategy — an antiproliferative stent plus short dual therapy — rather than one named product.
Source: Synthesis of Urban P et al. New England Journal of Medicine. 2015 (PMID: 26466021); Varenne O et al. Lancet. 2018 (PMID: 29102362).