Bioresorbable scaffolds: within the noninferiority margin for target-lesion failure at one year in ABSORB III (7.8% vs 6.1%) — but device thrombosis ran at 3.5% vs 0.9% through two years in AIDA (HR 3.87)

Shelf #3340 · Heart, vessels, blood pressure & clotting

SPLIT — ABSORB III (n=2,008): 1-year target-lesion failure 7.8% vs 6.1% (noninferior); AIDA (n=1,845): target-vessel failure 11.7% vs 10.7% but device thrombosis 3.5% vs 0.9% (HR 3.87; p<0.001)

Stamped: 2026-11-28.

Evidence published: 2015–2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In coronary disease, do bioresorbable scaffolds match metallic drug-eluting stents on target-lesion failure and stent thrombosis?

Balance of the evidence

SPLIT — the answer splits by endpoint: the scaffold matched on the composite it was designed to match, and lost on the complication that ended it. In ABSORB III (Ellis SG et al., PMID: 26457558), 2,008 patients with stable or unstable angina received an everolimus-eluting bioresorbable (Absorb) scaffold or an everolimus-eluting cobalt-chromium stent: target-lesion failure at one year occurred in 7.8% versus 6.1% (difference 1.7 percentage points, 95% CI −0.5 to 3.9; p=0.007 for noninferiority, p=0.16 for superiority), with device thrombosis in 1.5% versus 0.7% (p=0.13). In AIDA (Wykrzykowska JJ et al., PMID: 28402237), 1,845 patients undergoing routine PCI received the scaffold or a metallic stent: two-year target-vessel failure was 11.7% versus 10.7% (HR 1.12, 95% CI 0.85–1.48; p=0.43), but definite or probable device thrombosis occurred in 3.5% versus 0.9% (HR 3.87, 1.78–8.42; p<0.001), and the data and safety monitoring board recommended early reporting because of safety concerns. SPLIT: bioresorbable scaffolds were noninferior for one-year target-lesion failure in selected lesions, but carried a roughly fourfold device-thrombosis rate in routine practice — a harm that led to the Absorb scaffold's withdrawal from the market.

MeSH: Absorbable Implants · Aged · Angina Pectoris/therapy · Coronary Angiography · Coronary Artery Disease/mortality/therapy · Coronary Restenosis · Drug-Eluting Stents/adverse effects · Everolimus/administration & dosage · Female · Humans · Immunosuppressive Agents/administration & dosage · Kaplan-Meier Estimate · Male · Metals · Middle Aged · Prosthesis Design

Cards (3)

Card 1 — Ellis 2015 (ABSORB III, n=2,008): target-lesion failure 7.8% scaffold vs 6.1% metallic stent at 1 year — noninferior (p=0.007), not superior (p=0.16); device thrombosis 1.5% vs 0.7%

Study: Randomised trial (Ellis 2015, ABSORB III)

Population: 2,008 patients with stable or unstable angina and noncomplex obstructive coronary disease, assigned 2:1 to an everolimus-eluting bioresorbable vascular (Absorb) scaffold (n=1,322) or an everolimus-eluting cobalt-chromium (Xience) metallic stent (n=686); primary endpoint target-lesion failure at one year, tested for noninferiority (margin 4.5 percentage points) and superiority.

Summary: Ellis 2015 (ABSORB III, n=2,008): target-lesion failure 7.8% scaffold vs 6.1% metallic stent at 1 year — noninferior (p=0.007), not superior (p=0.16); device thrombosis 1.5% vs 0.7%

Result: Target-lesion failure at one year occurred in 7.8% of the Absorb group and 6.1% of the Xience group (difference 1.7 percentage points, 95% CI −0.5 to 3.9; p=0.007 for noninferiority, p=0.16 for superiority). Cardiac death (0.6% vs 0.1%; p=0.29), target-vessel myocardial infarction (6.0% vs 4.6%; p=0.18), and ischaemia-driven target-lesion revascularisation (3.0% vs 2.5%; p=0.50) did not differ significantly. Device thrombosis within one year occurred in 1.5% versus 0.7% (p=0.13). The scaffold was funded by Abbott Vascular.

Watch out: Noninferiority against a 4.5-point margin, in noncomplex lesions, at one year — before a bioresorbable device has finished resorbing — is the friendliest possible framing of this technology, and even here every component leaned toward the metal stent. The trial was not powered to judge thrombosis, which is where the technology failed.

Source: Ellis SG et al. Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease. New England Journal of Medicine. 2015. PMID: 26457558. Registry ID: NCT01751906. MeSH: Absorbable Implants · Aged · Angina Pectoris/therapy · Coronary Angiography · Coronary Artery Disease/mortality/therapy · Coronary Restenosis · Drug-Eluting Stents/adverse effects · Everolimus/administration & dosage · Female · Humans · Immunosuppressive Agents/administration & dosage · Kaplan-Meier Estimate · Male · Metals · Middle Aged · Prosthesis Design

Card 2 — Wykrzykowska 2017 (AIDA, n=1,845, routine practice): target-vessel failure 11.7% vs 10.7% (p=0.43) — but device thrombosis 3.5% vs 0.9% (HR 3.87; p<0.001); safety board forced early reporting

Study: Randomised trial (Wykrzykowska 2017, AIDA)

Population: 1,845 patients undergoing PCI in routine clinical practice, assigned to an everolimus-eluting bioresorbable scaffold (n=924) or an everolimus-eluting metallic stent (n=921); primary endpoint target-vessel failure; median follow-up 707 days; the data and safety monitoring board recommended early reporting because of safety concerns.

Summary: Wykrzykowska 2017 (AIDA, n=1,845, routine practice): target-vessel failure 11.7% vs 10.7% (p=0.43) — but device thrombosis 3.5% vs 0.9% (HR 3.87; p<0.001); safety board forced early reporting

Result: Target-vessel failure occurred in 105 scaffold patients and 94 stent patients (2-year cumulative rates 11.7% and 10.7%; hazard ratio 1.12, 95% CI 0.85–1.48; p=0.43). Cardiac death rates were 2.0% versus 2.7%, target-vessel myocardial infarction 5.5% versus 3.2%, and target-vessel revascularisation 8.7% versus 7.5%. Definite or probable device thrombosis occurred in 31 scaffold patients versus 8 stent patients (2-year rates 3.5% vs 0.9%; HR 3.87, 95% CI 1.78–8.42; p<0.001).

Watch out: AIDA's all-comers design is both its strength (this is what happened when ordinary operators used the device) and the scaffold's defence (implantation technique was still maturing). Either way, a fourfold thrombosis excess in a device whose selling point was long-term safety is disqualifying, and the commercial product was withdrawn.

Source: Wykrzykowska JJ et al. Bioresorbable Scaffolds versus Metallic Stents in Routine PCI. New England Journal of Medicine. 2017. PMID: 28402237. Registry ID: NCT01858077. MeSH: Absorbable Implants/adverse effects · Aged · Coronary Stenosis/therapy · Drug-Eluting Stents · Everolimus/administration & dosage · Female · Follow-Up Studies · Heart Diseases/mortality · Humans · Incidence · Kaplan-Meier Estimate · Male · Middle Aged · Myocardial Infarction/etiology · Percutaneous Coronary Intervention · Self Expandable Metallic Stents/adverse effects · Thrombosis/epidemiology/etiology · Treatment Outcome

Card 3 — Synthesis

Study: Synthesis

Population: Two randomised trials totalling 3,853 patients comparing the everolimus-eluting bioresorbable (Absorb) scaffold with metallic everolimus-eluting stents: ABSORB III (2,008 selected patients, 1-year endpoint) and AIDA (1,845 routine-practice patients, 2-year follow-up).

Summary: Synthesis

Result: Target-lesion/vessel failure: 7.8% vs 6.1% at 1 year (noninferior) and 11.7% vs 10.7% at 2 years. Device thrombosis: 1.5% vs 0.7% at 1 year; 3.5% vs 0.9% at 2 years (HR 3.87). SPLIT — matched on the failure composite, clearly worse on thrombosis.

Watch out: Tier C is set because the shelf carries a harm claim (device thrombosis). Newer scaffold designs are different devices; this shelf is the evidence record for the Absorb generation that reached patients and was withdrawn.

Source: Synthesis of Ellis SG et al. New England Journal of Medicine. 2015 (PMID: 26457558); Wykrzykowska JJ et al. New England Journal of Medicine. 2017 (PMID: 28402237).