SourceMed · Shelf #3341 in the ask interface
Drug-coated balloon for small coronary vessels (BASKET-SMALL 2): major events 7.5% vs 7.3% at one year — noninferior to a drug-eluting stent, with nothing left behind
Shelf #3341 · Heart, vessels, blood pressure & clotting
POSSIBLE (the treatment made no difference) — BASKET-SMALL 2 (n=758): 12-month major events 7.5% (balloon) vs 7.3% (stent), HR 0.97; noninferiority met; cardiac deaths numerically higher on balloon (3.1% vs 1.3%), unresolved
Stamped: 2026-11-28.
Evidence published: 2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In small native coronary vessels, does a drug-coated balloon match a drug-eluting stent for late lumen loss and clinical events?
Balance of the evidence
POSSIBLE (the treatment made no difference) — in the one randomised test, the balloon matched the stent on events. In BASKET-SMALL 2 (Jeger RV et al., PMID: 30170854), 758 patients with de-novo lesions in coronary vessels under 3 mm in diameter were randomised after successful predilatation to a paclitaxel drug-coated balloon or a second-generation drug-eluting stent. At 12 months, major adverse cardiac events (cardiac death, nonfatal myocardial infarction, target-vessel revascularisation) occurred in 7.5% on the balloon versus 7.3% on the stent (hazard ratio 0.97, 95% CI 0.58–1.64; p=0.9180), and noninferiority was formally shown in the per-protocol population (absolute difference 95% CI −3.83 to 3.93%, inside the 4% margin; p=0.0217). Cardiac deaths were 12 (3.1%) on the balloon versus 5 (1.3%) on the stent — a numerical imbalance the trial was not powered to resolve — while probable or definite stent thrombosis (0.8% vs 1.1%) and major bleeding (1.1% vs 2.4%) were similar. POSSIBLE (the treatment made no difference): in small native vessels, a drug-coated balloon gives one-year clinical results statistically indistinguishable from a drug-eluting stent; the question the candidate asked about late lumen loss was not this trial's primary measure, and the shelf says so.
MeSH: Aged · Angioplasty, Balloon, Coronary/methods · Coated Materials, Biocompatible/therapeutic use · Coronary Artery Disease/therapy · Drug-Eluting Stents · Female · Humans · Male · Middle Aged · Percutaneous Coronary Intervention/methods · Proportional Hazards Models · Prospective Studies
Cards (2)
Card 1 — Jeger 2018 (BASKET-SMALL 2, n=758): major events 7.5% vs 7.3% at 12 months (HR 0.97) — noninferiority shown; cardiac death 3.1% vs 1.3% numerically favoured the stent
Study: Randomised open-label non-inferiority trial (Jeger 2018, BASKET-SMALL 2)
Population: 758 patients with de-novo lesions (<3 mm diameter) in coronary vessels and an indication for PCI, at multiple centres, randomly allocated after successful predilatation to angioplasty with a paclitaxel drug-coated balloon (n=382) or implantation of a second-generation drug-eluting stent (n=376); dual antiplatelet therapy per current guidelines; primary objective noninferiority for major adverse cardiac events at 12 months (margin: absolute difference of 4%).
Summary: Jeger 2018 (BASKET-SMALL 2, n=758): major events 7.5% vs 7.3% at 12 months (HR 0.97) — noninferiority shown; cardiac death 3.1% vs 1.3% numerically favoured the stent
Result: Noninferiority was shown: in the per-protocol population the 95% CI of the absolute difference in major adverse cardiac events was below the predefined margin (−3.83 to 3.93%; p=0.0217). At 12 months in the full-analysis population, major events (cardiac death, nonfatal myocardial infarction, target-vessel revascularisation) occurred in 7.5% on the balloon versus 7.3% on the stent (hazard ratio 0.97, 95% CI 0.58–1.64; p=0.9180). Cardiac deaths numbered 5 (1.3%) on the stent and 12 (3.1%) on the balloon; probable or definite stent thrombosis occurred in 3 (0.8%) balloon versus 4 (1.1%) stent patients, and major bleeding in 4 (1.1%) versus 9 (2.4%).
Watch out: Open-label, one year of follow-up, and a noninferiority margin of 4 absolute points on a 7% event rate is generous — 'not proven worse by more than half again' is the precise claim. The cardiac-death imbalance (12 vs 5) is small-number noise until it isn't; longer follow-up of this cohort matters more than the headline.
Source: Jeger RV et al. Drug-coated balloons for small coronary artery disease (BASKET-SMALL 2): an open-label randomised non-inferiority trial. Lancet. 2018. PMID: 30170854. Registry ID: NCT01574534. MeSH: Aged · Angioplasty, Balloon, Coronary/methods · Coated Materials, Biocompatible/therapeutic use · Coronary Artery Disease/therapy · Drug-Eluting Stents · Female · Humans · Male · Middle Aged · Percutaneous Coronary Intervention/methods · Proportional Hazards Models · Prospective Studies
Card 2 — Synthesis
Study: Synthesis
Population: One randomised non-inferiority trial of 758 patients with small (<3 mm) native coronary vessel disease, drug-coated balloon versus second-generation drug-eluting stent, 12 months.
Summary: Synthesis
Result: Major adverse cardiac events: 7.5% vs 7.3% (HR 0.97). Noninferiority met against a 4-point margin. Cardiac death: 3.1% vs 1.3% (numerical, unresolved). POSSIBLE (the treatment made no difference) on one-year clinical events.
Watch out: Tier C is set: a single trial. The candidate question also asked about late lumen loss; BASKET-SMALL 2's primary measure was clinical events, so the shelf answers the events half and declares the angiographic half unaddressed by its anchor rather than borrowing numbers from elsewhere.
Source: Synthesis of Jeger RV et al. Lancet. 2018 (PMID: 30170854).