SourceMed · Shelf #3342 in the ask interface

Drug-coated balloon for in-stent restenosis: clearly better than a plain balloon (target-lesion failure 17.9% vs 28.6% in AGENT IDE) — clinically level with a repeat drug-eluting stent in RIBS V, though the stent left a wider lumen

Shelf #3342 · Heart, vessels, blood pressure & clotting

SPLIT — AGENT IDE (n=600): target-lesion failure 17.9% vs 28.6% vs uncoated balloon (HR 0.59); RIBS V (n=189): clinical outcome 6% vs 8% vs everolimus stent (NS), but lumen diameter 2.01 vs 2.36 mm favoured the stent

Stamped: 2026-11-28.

Evidence published: 2014–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

For in-stent restenosis, does a drug-coated balloon match repeat drug-eluting stenting or balloon angioplasty for recurrence and events?

Balance of the evidence

SPLIT — the answer splits by comparator. Against a plain balloon, the drug-coated balloon wins outright: in AGENT IDE (Yeh RW et al., PMID: 38460161), 600 patients with in-stent restenosis received a paclitaxel-coated or an uncoated balloon; one-year target-lesion failure occurred in 17.9% versus 28.6% (hazard ratio 0.59, 95% CI 0.42–0.84; p=0.003), with target-lesion revascularisation in 13.0% versus 24.7% and target-vessel myocardial infarction in 5.8% versus 11.1%, though cardiac death was numerically higher on the coated balloon (2.9% vs 1.6%; HR 1.75, 0.49–6.28; p=0.38). Against a repeat drug-eluting stent, it is a draw clinically and a loss angiographically: in RIBS V (Alfonso F et al., PMID: 24412457), 189 patients with bare-metal-stent restenosis received a drug-eluting balloon or an everolimus-eluting stent; the combined clinical outcome was 6% versus 8% (HR 0.76, 0.26–2.18; p=0.6) and target-vessel revascularisation 2% versus 6%, but minimal lumen diameter at follow-up was significantly larger with the stent (2.36 mm vs 2.01 mm; p<0.001). SPLIT: for in-stent restenosis, a drug-coated balloon beats plain angioplasty and matches repeat stenting on clinical events, while leaving a narrower lumen than a new stent.

MeSH: Female · Humans · Aged · Paclitaxel · Coronary Restenosis/etiology/therapy · Stents · Treatment Outcome · Myocardial Infarction · Death

Cards (3)

Card 1 — Yeh 2024 (AGENT IDE, n=600): target-lesion failure 17.9% on paclitaxel-coated balloon vs 28.6% on uncoated balloon (HR 0.59; p=0.003) — superiority met

Study: Randomised clinical trial (Yeh 2024, AGENT IDE)

Population: 600 patients with in-stent restenosis (lesion length <26 mm, reference vessel diameter >2.0 to ≤4.0 mm) at 40 United States centres, randomised 2:1 to a paclitaxel-coated balloon (n=406) or an uncoated balloon (n=194); mean age 68 years; 95.7% completed one-year follow-up.

Summary: Yeh 2024 (AGENT IDE, n=600): target-lesion failure 17.9% on paclitaxel-coated balloon vs 28.6% on uncoated balloon (HR 0.59; p=0.003) — superiority met

Result: The primary endpoint of one-year target-lesion failure (ischaemia-driven target-lesion revascularisation, target-vessel myocardial infarction, or cardiac death) occurred in 17.9% on the paclitaxel-coated balloon versus 28.6% on the uncoated balloon (hazard ratio 0.59, 95% CI 0.42–0.84; p=0.003), meeting superiority. Target-lesion revascularisation occurred in 13.0% versus 24.7% (HR 0.50, 0.34–0.74; p=0.001) and target-vessel MI in 5.8% versus 11.1% (HR 0.51, 0.28–0.92; p=0.02). Cardiac death was 2.9% versus 1.6% (HR 1.75, 0.49–6.28; p=0.38).

Watch out: The comparator is a plain balloon — the weakest available treatment — so superiority here establishes that the drug coating works, not that the balloon is the best option. The cardiac-death point estimate leans the wrong way on very few events; it does not overturn the composite, but it forbids calling the win costless.

Source: Yeh RW et al. Paclitaxel-Coated Balloon vs Uncoated Balloon for Coronary In-Stent Restenosis: The AGENT IDE Randomized Clinical Trial. JAMA. 2024. PMID: 38460161. Registry ID: NCT04647253. MeSH: Female · Humans · Aged · Paclitaxel · Coronary Restenosis/etiology/therapy · Stents · Treatment Outcome · Myocardial Infarction · Death

Card 2 — Alfonso 2014 (RIBS V, n=189, bare-metal-stent restenosis): clinical outcome 6% (balloon) vs 8% (everolimus stent), p=0.6 — but minimal lumen diameter 2.01 vs 2.36 mm favoured the stent (p<0.001)

Study: Randomised trial (Alfonso 2014, RIBS V)

Population: 189 patients with bare-metal-stent in-stent restenosis at 25 Spanish sites, allocated to a paclitaxel drug-eluting balloon (n=95) or an everolimus-eluting stent (n=94); primary endpoint minimal lumen diameter at 9 months; angiographic follow-up in 92% of eligible patients at a median of 249 days; clinical follow-up in all patients at a median of 365 days.

Summary: Alfonso 2014 (RIBS V, n=189, bare-metal-stent restenosis): clinical outcome 6% (balloon) vs 8% (everolimus stent), p=0.6 — but minimal lumen diameter 2.01 vs 2.36 mm favoured the stent (p<0.001)

Result: At late angiography, the stent arm had a significantly larger minimal lumen diameter (2.36 ± 0.6 mm vs 2.01 ± 0.6 mm; p<0.001; absolute mean difference 0.35 mm, 95% CI 0.16–0.53) and a lower percent diameter stenosis (13 ± 17% vs 25 ± 20%; p<0.001), while late loss (0.04 ± 0.5 mm vs 0.14 ± 0.5 mm; p=0.14) and binary restenosis (4.7% vs 9.5%; p=0.22) were low and similar. The combined clinical outcome (cardiac death, myocardial infarction, target-vessel revascularisation) occurred in 6% versus 8% (hazard ratio 0.76, 95% CI 0.26–2.18; p=0.6), and target-vessel revascularisation in 2% versus 6% (HR 0.32, 0.07–1.59; p=0.17).

Watch out: A 189-patient trial cannot declare clinical equivalence — its confidence interval for the clinical composite runs from a 74% relative reduction to a doubling. What it does show is the recurring pattern of this comparison: the stent wins the angiogram, the balloon avoids another metal layer, and one year of events cannot tell them apart.

Source: Alfonso F et al. A randomized comparison of drug-eluting balloon versus everolimus-eluting stent in patients with bare-metal stent-in-stent restenosis: the RIBS V Clinical Trial (Restenosis Intra-stent of Bare Metal Stents: paclitaxel-eluting balloon vs. everolimus-eluting stent). Journal of the American College of Cardiology. 2014. PMID: 24412457. Registry ID: NCT01239953. MeSH: Aged · Angioplasty, Balloon, Coronary/instrumentation/methods/mortality · Coronary Angiography/methods · Coronary Restenosis/diagnostic imaging/mortality/therapy · Coronary Stenosis/diagnostic imaging/mortality/therapy · Drug-Eluting Stents · Female · Follow-Up Studies · Humans · Male · Metals · Middle Aged · Paclitaxel/therapeutic use · Prospective Studies · Prosthesis Design · Prosthesis Failure · Risk Assessment · Severity of Illness Index · Sirolimus/therapeutic use · Spain · Survival Rate · Treatment Outcome

Card 3 — Synthesis

Study: Synthesis

Population: Two randomised trials in in-stent restenosis: AGENT IDE (600 patients, drug-coated balloon vs uncoated balloon) and RIBS V (189 patients with bare-metal-stent restenosis, drug-eluting balloon vs everolimus-eluting stent).

Summary: Synthesis

Result: Versus plain balloon: target-lesion failure 17.9% vs 28.6% (HR 0.59). Versus repeat stent: clinical outcome 6% vs 8% (not significant), minimal lumen diameter 2.01 vs 2.36 mm favouring the stent. SPLIT — beats angioplasty alone; matches repeat stenting clinically at one year, not angiographically.

Watch out: Tier C is not set: two randomised trials with complementary comparators carry the split. Restenosis of a drug-eluting stent (the common modern case) is represented in AGENT IDE's mixed population but was not RIBS V's population — that distinction is on the face of the cards.

Source: Synthesis of Yeh RW et al. JAMA. 2024 (PMID: 38460161); Alfonso F et al. Journal of the American College of Cardiology. 2014 (PMID: 24412457).