SourceMed · Shelf #3346 in the ask interface

Vascular closure devices after catheterisation: haemostasis is faster, major complications are no different — but groin infection is more frequent (0.6% vs 0.2%) in a meta-analysis of 31 randomised trials

Shelf #3346 · Heart, vessels, blood pressure & clotting

SPLIT — Biancari 2010 meta-analysis (31 RCTs, 7,528 patients): time to haemostasis significantly shorter; haematoma, bleeding, pseudoaneurysm and transfusion similar; groin infection 0.6% vs 0.2% (p=0.02)

Stamped: 2026-11-28.

Evidence published: 2010.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

After coronary stenting, do vascular closure devices reduce access-site complications and time to walking compared with manual compression?

Balance of the evidence

SPLIT — the answer splits by endpoint: speed yes, safety neutral-to-worse. A meta-analysis of 31 prospective randomised studies (Biancari F et al., PMID: 20362708) including 7,528 patients randomised to a vascular closure device or manual/mechanical compression after diagnostic angiography and/or endovascular procedures found similar results for groin haematoma, bleeding, pseudoaneurysm, and blood transfusion. Lower-limb ischaemia and other arterial ischaemic complications (0.3% vs 0%; p=0.07) and the need for surgery for vascular complications (0.7% vs 0.4%; p=0.10) were somewhat more frequent with closure devices, and groin infection was significantly more frequent (0.6% vs 0.2%; p=0.02). The one uniform advantage was a significantly shorter time to haemostasis with closure devices, more evident in patients undergoing PCI than in those undergoing diagnostic angiography, among whom adverse-event rates were similar. SPLIT: closure devices shorten time to haemostasis (and so may shorten recovery) without reducing access-site complications, and they add a small excess of groin infection and device-specific arterial complications.

MeSH: Angiography · Angioplasty · Bandages · Blood Vessels · Humans · Pressure · Randomized Controlled Trials as Topic

Cards (2)

Card 1 — Biancari 2010 (meta-analysis of 31 randomised trials, 7,528 patients): faster haemostasis with closure devices; infection 0.6% vs 0.2% (p=0.02); haematoma, bleeding, pseudoaneurysm, transfusion all similar

Study: Meta-analysis of randomised trials (Biancari 2010)

Population: 31 prospective randomised studies including 7,528 patients randomised to vascular closure devices or manual/mechanical compression after diagnostic angiography and/or endovascular procedures; most studies excluded patients at high risk of puncture-site complications.

Summary: Biancari 2010 (meta-analysis of 31 randomised trials, 7,528 patients): faster haemostasis with closure devices; infection 0.6% vs 0.2% (p=0.02); haematoma, bleeding, pseudoaneurysm, transfusion all similar

Result: Meta-analysis showed similar results in the two groups for groin haematoma, bleeding, pseudoaneurysm, and blood transfusion. Lower-limb ischaemia and other arterial ischaemic complications (0.3% vs 0%; p=0.07) and need for surgery for vascular complications (0.7% vs 0.4%; p=0.10) were somewhat more frequent with closure devices, and groin infection was significantly more frequent with closure devices (0.6% vs 0.2%; p=0.02). Use of a closure device was uniformly associated with a significantly shorter time to haemostasis, a difference more evident in patients undergoing PCI; among patients undergoing diagnostic coronary angiography, the methods had similar adverse-event rates.

Watch out: The trials pooled several device generations and mechanisms (clips, sutures, collagen plugs) as one intervention, and they mostly excluded the high-risk groins where a device might help or harm most. 'Time to haemostasis' is a process prize — the candidate question's 'time to walking' was not the meta-analysis's reported endpoint, and the shelf does not pretend otherwise.

Source: Biancari F et al. Meta-analysis of randomized trials on the efficacy of vascular closure devices after diagnostic angiography and angioplasty. American Heart Journal. 2010. PMID: 20362708. MeSH: Angiography · Angioplasty · Bandages · Blood Vessels · Humans · Pressure · Randomized Controlled Trials as Topic

Card 2 — Synthesis

Study: Synthesis

Population: One meta-analysis of 31 prospective randomised studies totalling 7,528 patients, vascular closure devices versus manual or mechanical compression after angiography or endovascular procedures.

Summary: Synthesis

Result: Time to haemostasis: significantly shorter with devices. Complications: haematoma, bleeding, pseudoaneurysm, transfusion — similar; groin infection 0.6% vs 0.2% (p=0.02); arterial ischaemic complications 0.3% vs 0% (p=0.07). SPLIT — a convenience benefit, no safety benefit, a small infection cost.

Watch out: Tier C is not set: the base is a meta-analysis of randomised trials. The evidence is from the femoral-access era; radial access has since shrunk the population to whom this question applies, which the shelf's readers should know.

Source: Synthesis of Biancari F et al. American Heart Journal. 2010 (PMID: 20362708).