SourceMed · Shelf #3359 in the ask interface
OCT versus IVUS guidance for PCI: target-vessel failure 2.5% versus 3.1% in OCTIVUS and 5.2% versus 4.9% in OPINION — the light-based camera matched ultrasound in both trials
Shelf #3359 · Heart, vessels, blood pressure & clotting
POSSIBLE (the treatment made no difference) — OCT-guided PCI was noninferior to IVUS-guided PCI in both OCTIVUS (2.5% versus 3.1%) and OPINION (5.2% versus 4.9%)
Stamped: 2026-11-28.
Evidence published: 2017–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
For guiding PCI, does optical coherence tomography match intravascular ultrasound for death, myocardial infarction, and revascularisation?
Balance of the evidence
POSSIBLE (the treatment made no difference) — two randomised head-to-head trials, both meeting noninferiority. OCTIVUS (Kang DY et al., PMID: 37634092) randomised 2,008 patients to OCT-guided or IVUS-guided PCI: the composite of cardiac death, target-vessel myocardial infarction, or ischaemia-driven target-vessel revascularisation at 1 year occurred in 25 patients (2.5%) on OCT guidance versus 31 (3.1%) on IVUS guidance (absolute difference −0.6 percentage points; p<0.001 for noninferiority), with contrast-induced nephropathy in 1.4% versus 1.5% and major procedural complications in 2.2% versus 3.7% (p=0.047). OPINION (Kubo T et al., PMID: 29121226) found target-vessel failure in 5.2% on optical frequency-domain imaging versus 4.9% on IVUS at 12 months (noninferiority p=0.042), with identical in-stent restenosis rates of 1.6%. POSSIBLE (the treatment made no difference): OCT is not better than IVUS — it is, on two trials, its equal.
MeSH: Humans · Percutaneous Coronary Intervention/adverse effects/methods · Coronary Angiography/methods · Tomography, Optical Coherence/methods · Prospective Studies · Drug-Eluting Stents/adverse effects · Ultrasonography, Interventional/adverse effects/methods · Treatment Outcome · Myocardial Infarction/etiology · Coronary Artery Disease/diagnostic imaging/surgery
Cards (3)
Card 1 — Kang 2023 (OCTIVUS): primary endpoint 2.5% on OCT guidance versus 3.1% on IVUS guidance (p<0.001 for noninferiority); major procedural complications 2.2% versus 3.7%
Study: Randomised open-label pragmatic trial (Kang 2023, OCTIVUS)
Population: 2,008 patients with significant coronary artery lesions undergoing PCI at South Korean centres, randomised 1:1 to OCT-guided (1,005 patients) or IVUS-guided (1,003 patients) PCI with drug-eluting stents; primary endpoint at 1 year.
Summary: Kang 2023 (OCTIVUS): primary endpoint 2.5% on OCT guidance versus 3.1% on IVUS guidance (p<0.001 for noninferiority); major procedural complications 2.2% versus 3.7%
Result: Primary end point events (cardiac death, target-vessel myocardial infarction, or ischaemia-driven target-vessel revascularisation) occurred in 25 patients in the OCT group (Kaplan–Meier estimate 2.5%) and 31 in the IVUS group (3.1%) — absolute difference −0.6 percentage points (upper boundary of the one-sided 97.5% CI 0.97 points; p<0.001 for noninferiority). Contrast-induced nephropathy occurred in 14 patients (1.4%) versus 15 (1.5%) (p=0.85); major procedural complications in 22 (2.2%) versus 37 (3.7%) (p=0.047), with no imaging procedure-related complications observed.
Watch out: Event rates were lower than expected, which widens the practical meaning of 'noninferior' — with 56 total events, the trial shows the strategies are close, not that they are identical, and the authors themselves flag the selected study population. Open-label design; operators knew which camera they were using.
Source: Kang DY et al. Optical Coherence Tomography-Guided or Intravascular Ultrasound-Guided Percutaneous Coronary Intervention: The OCTIVUS Randomized Clinical Trial. Circulation. 2023. PMID: 37634092. Registry ID: NCT03394079. MeSH: Humans · Percutaneous Coronary Intervention/adverse effects/methods · Coronary Angiography/methods · Tomography, Optical Coherence/methods · Prospective Studies · Drug-Eluting Stents/adverse effects · Ultrasonography, Interventional/adverse effects/methods · Treatment Outcome · Myocardial Infarction/etiology · Coronary Artery Disease/diagnostic imaging/surgery
Card 2 — Kubo 2017 (OPINION): target-vessel failure 5.2% on optical imaging versus 4.9% on IVUS (noninferiority p=0.042); in-stent restenosis 1.6% in both groups
Study: Randomised non-inferiority trial (Kubo 2017, OPINION)
Population: 829 patients undergoing PCI with a second-generation drug-eluting stent at Japanese centres, randomised 1:1 to optical frequency domain imaging (OFDI, the OCT variant used; 414 patients) or IVUS guidance (415 patients); primary endpoint target-vessel failure to 12 months, angiographic follow-up in 89.8%.
Summary: Kubo 2017 (OPINION): target-vessel failure 5.2% on optical imaging versus 4.9% on IVUS (noninferiority p=0.042); in-stent restenosis 1.6% in both groups
Result: Target-vessel failure (cardiac death, target-vessel myocardial infarction, or ischaemia-driven target-vessel revascularisation) occurred in 21 of 401 patients (5.2%) with OFDI guidance and 19 of 390 (4.9%) with IVUS guidance (hazard ratio 1.07; upper limit of the one-sided 95% CI 1.80; p for noninferiority 0.042). Binary restenosis at 8 months was identical in-stent (1.6% versus 1.6%; p=1.00) and near-identical in-segment (6.2% versus 6.0%; p=1.00).
Watch out: OPINION used one stent platform and one OFDI system in Japanese practice, and its noninferiority margin was generous relative to a 5% event rate — the upper confidence limit of 1.80 on the hazard ratio allows meaningful harm that the point estimate hides. Both trials answer 'is OCT as good', not 'is either better than angiography alone'.
Source: Kubo T et al. Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): one-year angiographic and clinical results. European Heart Journal. 2017. PMID: 29121226. Registry ID: NCT01873027. MeSH: Adult · Aged · Aged, 80 and over · Coronary Angiography/methods · Coronary Stenosis/diagnostic imaging/surgery · Drug-Eluting Stents · Female · Humans · Male · Middle Aged · Percutaneous Coronary Intervention/adverse effects/methods · Postoperative Complications/etiology · Prospective Studies · Surgery, Computer-Assisted/methods · Tomography, Optical Coherence/methods · Treatment Outcome · Ultrasonography, Interventional/methods · Young Adult
Card 3 — Synthesis: 2,837 patients across two trials — choose the camera your lab knows; the outcomes will not notice
Study: Synthesis
Population: Two randomised non-inferiority trials of OCT-family guidance versus IVUS guidance for PCI: OCTIVUS (2,008 patients, 1-year clinical composite) and OPINION (829 patients, 12-month target-vessel failure plus 8-month angiography).
Summary: Synthesis: 2,837 patients across two trials — choose the camera your lab knows; the outcomes will not notice
Result: Primary composites: 2.5% versus 3.1% (OCTIVUS) and 5.2% versus 4.9% (OPINION), both meeting noninferiority; restenosis identical where measured. POSSIBLE (the treatment made no difference).
Watch out: Noninferiority is a bounded claim: both trials permit small differences in either direction, and neither was powered for death alone. Tier C is not set: two concordant randomised trials carry the equivalence.
Source: Synthesis of Kang DY et al. Circulation. 2023 (PMID: 37634092); Kubo T et al. European Heart Journal. 2017 (PMID: 29121226).