Prosthetic valve thrombosis: ultraslow low-dose thrombolysis freed 90% of valves in PROMETEE with 6.7% complications — but the older pooled comparison says surgery embolises and bleeds less
Shelf #3363 · Heart, vessels, blood pressure & clotting
SPLIT — PROMETEE's ultraslow regimen achieved 90% success with 6.7% complications in a single-arm series, while the pooled observational comparison favoured surgery for embolism, bleeding, and recurrence
Stamped: 2026-11-28.
Evidence published: 2013–2015.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In prosthetic valve thrombosis, does slow-infusion low-dose thrombolysis match surgery for success, embolism, and bleeding?
Balance of the evidence
SPLIT — the modern regimen looks gentle; the comparative evidence is old and points the other way. PROMETEE (Özkan M et al., PMID: 26299240) treated 114 patients (120 episodes of prosthetic valve thrombosis, 64.2% obstructive) at a single centre with transoesophageal-echo-guided ultraslow infusion of low-dose alteplase (25 mg over 25 hours, no bolus): overall thrombolytic success was 90% (95% CI 0.85–0.95) with an overall complication rate of 6.7% (3.3% nonfatal major, 2.5% minor, 0.8% death). The comparative record is a meta-analysis of observational studies (Karthikeyan G et al., PMID: 23329151) pooling 690 episodes: complete restoration of valve function in 86.5% with urgent surgery versus 69.7% with fibrinolysis (odds ratio 2.53; p=0.066, not significant), death in 13.5% versus 9% (odds ratio 1.95; not significant), but thromboembolism in 1.6% versus 16% (odds ratio 0.10; p<0.001), major bleeding in 1.4% versus 5% (odds ratio 0.27), and recurrent thrombosis in 7.1% versus 25.4% (odds ratio 0.25) — all favouring surgery. SPLIT: ultraslow thrombolysis succeeds often with few complications in expert hands, but it has never been randomised against surgery, and the regimens in the comparative pool predate it.
MeSH: Adult · Aged · Aged, 80 and over · Dose-Response Relationship, Drug · Echocardiography, Transesophageal · Female · Fibrinolytic Agents/administration & dosage · Follow-Up Studies · Heart Diseases/diagnosis/drug therapy/etiology · Heart Valve Diseases/complications/surgery · Heart Valve Prosthesis/adverse effects · Heart Ventricles · Humans · Infusions, Intravenous · Male · Middle Aged · Postoperative Complications · Practice Guidelines as Topic · Prosthesis Failure · Retrospective Studies · Thrombolytic Therapy/methods · Thrombosis/diagnostic imaging/drug therapy/etiology · Time Factors · Treatment Outcome · Young Adult
Cards (3)
Card 1 — Özkan 2015 (Ultra-slow PROMETEE): success 90% across 120 thrombosis episodes; complications 6.7% total, death 0.8% — with no surgical comparator
Study: Single-centre prospective case series (Özkan 2015, Ultra-slow PROMETEE)
Population: 114 patients with prosthetic (mechanical) valve thrombosis in 120 episodes treated at one Turkish centre, 2009–2013 — obstructive thrombosis in 77 episodes (64.2%), nonobstructive in 43 (35.8%) — all receiving transoesophageal-echocardiography-guided ultraslow infusion of low-dose alteplase, 25 mg over 25 hours without bolus, repeated as needed.
Summary: Özkan 2015 (Ultra-slow PROMETEE): success 90% across 120 thrombosis episodes; complications 6.7% total, death 0.8% — with no surgical comparator
Result: Overall thrombolytic success was 90% (95% CI 0.85–0.95). The overall complication rate was 6.7%: 3.3% nonfatal major, 2.5% minor, and 0.8% death. Predictors of unsuccessful thrombolysis included higher NYHA class (the only independent predictor on multivariable analysis), thrombus cross-sectional area, duration of suboptimal anticoagulation, lower baseline valve area, and atrial fibrillation; predictors of complications were atrial fibrillation, higher NYHA class, and thrombus area.
Watch out: There is no comparison group at all: 90% success in a centre that pioneered the technique, in episodes two-thirds obstructive, cannot be set against surgical results from other eras and centres. NYHA class IV patients fared worst — exactly the patients for whom the surgery-versus-lysis decision is hardest.
Source: Özkan M et al. Ultraslow thrombolytic therapy: A novel strategy in the management of PROsthetic MEchanical valve Thrombosis and the prEdictors of outcomE: The Ultra-slow PROMETEE trial. American Heart Journal. 2015. PMID: 26299240. MeSH: Adult · Aged · Aged, 80 and over · Dose-Response Relationship, Drug · Echocardiography, Transesophageal · Female · Fibrinolytic Agents/administration & dosage · Follow-Up Studies · Heart Diseases/diagnosis/drug therapy/etiology · Heart Valve Diseases/complications/surgery · Heart Valve Prosthesis/adverse effects · Heart Ventricles · Humans · Infusions, Intravenous · Male · Middle Aged · Postoperative Complications · Practice Guidelines as Topic · Prosthesis Failure · Retrospective Studies · Thrombolytic Therapy/methods · Thrombosis/diagnostic imaging/drug therapy/etiology · Time Factors · Treatment Outcome · Young Adult
Card 2 — Karthikeyan 2013: valve function restored 86.5% (surgery) versus 69.7% (fibrinolysis), not significant — but thromboembolism 1.6% versus 16% (OR 0.10) and recurrence 7.1% versus 25.4% (OR 0.25) favoured surgery
Study: Meta-analysis of observational studies (Karthikeyan 2013)
Population: 7 observational studies including 690 episodes of left-sided prosthetic valve thrombosis — 446 treated with urgent surgery and 244 with fibrinolytic therapy — each study contributing at least 5 patients per treatment.
Summary: Karthikeyan 2013: valve function restored 86.5% (surgery) versus 69.7% (fibrinolysis), not significant — but thromboembolism 1.6% versus 16% (OR 0.10) and recurrence 7.1% versus 25.4% (OR 0.25) favoured surgery
Result: Complete restoration of valve function did not differ significantly: 86.5% with surgery versus 69.7% with fibrinolysis (odds ratio 2.53; 95% CI 0.94–6.78; p=0.066). In-hospital death was 13.5% versus 9% (odds ratio 1.95; 95% CI 0.63–5.98; p=0.244). Surgery was associated with significantly less thromboembolism (1.6% versus 16%; odds ratio 0.10; 95% CI 0.04–0.24; p<0.001), major bleeding (1.4% versus 5%; odds ratio 0.27; 95% CI 0.08–0.98; p=0.046), and recurrent prosthetic valve thrombosis (7.1% versus 25.4%; odds ratio 0.25; 95% CI 0.08–0.74; p=0.013).
Watch out: The fibrinolysis in these studies is largely older, faster, higher-dose practice — not the PROMETEE ultraslow regimen — so the embolism gap may describe a superseded technique; and sicker patients are channelled to lysis when surgery is refused or impossible, biasing death and success comparisons in unknowable directions. Heterogeneity for the primary outcome was high (I²=74%).
Source: Karthikeyan G et al. Urgent surgery compared with fibrinolytic therapy for the treatment of left-sided prosthetic heart valve thrombosis: a systematic review and meta-analysis of observational studies. European Heart Journal. 2013. PMID: 23329151. MeSH: Emergency Treatment/methods · Female · Fibrinolytic Agents/therapeutic use · Graft Occlusion, Vascular/therapy · Heart Valve Prosthesis · Hemorrhage/etiology · Humans · Male · Middle Aged · Observational Studies as Topic · Postoperative Complications/etiology · Prosthesis Failure · Recurrence · Thromboembolism/etiology · Treatment Outcome
Card 3 — Synthesis: success rates overlap; the safety comparison depends entirely on which decade's thrombolysis you mean
Study: Synthesis
Population: One single-arm series of the modern ultraslow regimen (PROMETEE, 120 episodes) and one meta-analysis of observational surgery-versus-fibrinolysis comparisons (690 episodes, largely older regimens). No randomised trial in either record.
Summary: Synthesis: success rates overlap; the safety comparison depends entirely on which decade's thrombolysis you mean
Result: Ultraslow lysis success 90%, complications 6.7%, death 0.8% (single-arm). Pooled older comparison: success 86.5% versus 69.7% (NS), death 13.5% versus 9% (NS), thromboembolism 1.6% versus 16% favouring surgery. SPLIT.
Watch out: The two cards cannot be combined into a single verdict: PROMETEE's low complication rate is precisely the claim the older pool cannot test. A 2024 observational comparison restricted to patients without haemodynamic compromise exists in the literature but was not carded here; the coordinator may wish to note it as a reference-add candidate.
Source: Synthesis of Özkan M et al. American Heart Journal. 2015 (PMID: 26299240); Karthikeyan G et al. European Heart Journal. 2013 (PMID: 23329151).