Defibrillation testing at ICD implant: skipping it was noninferior in 3,577 randomised patients — first-shock efficacy and arrhythmic death unchanged (SIMPLE; NORDIC ICD)
Shelf #3368 · Heart, vessels, blood pressure & clotting
POSSIBLE (the treatment made no difference) — omitting defibrillation testing was noninferior for shock efficacy and arrhythmic death in both SIMPLE and NORDIC ICD
Stamped: 2026-11-28.
Evidence published: 2015.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In ICD recipients, does omitting defibrillation threshold testing at implant worsen shock efficacy or survival compared with routine testing?
Balance of the evidence
POSSIBLE (the treatment made no difference) — where 'the treatment' is the test itself. SIMPLE (Healey JS et al., PMID: 25715991) randomised 2,500 first-ICD patients to implantation with or without defibrillation testing: the composite of arrhythmic death or failed appropriate shock occurred in 90 patients in the no-testing group versus 104 with testing (hazard ratio 0.86; 95% CI 0.65–1.14; p<0.0001 for noninferiority) over a mean 3.1 years, and 30-day safety composites were 5.6% versus 6.5% (p=0.33) and 3.2% versus 4.5% (p=0.08). NORDIC ICD (Bänsch D et al., PMID: 26112885) randomised 1,077 patients and found model-based first-shock efficacy noninferior without testing (difference 3.0% in favour of no testing; p for noninferiority <0.001), with procedure-related serious adverse events in 17.6% of tested patients versus 13.9% untested (p=0.095). POSSIBLE (the treatment made no difference): routine testing at first implant can be omitted — it found nothing, fixed nothing, and its own risks were the only ones that showed up at all.
MeSH: Arrhythmias, Cardiac/mortality/therapy · Defibrillators, Implantable · Electric Countershock/methods/mortality · Female · Heart Failure/etiology · Humans · Male · Middle Aged · Patient Safety · Postoperative Complications/etiology/mortality · Prognosis · Prosthesis Implantation/methods/mortality · Risk Assessment · Single-Blind Method · Ventricular Fibrillation/etiology
Cards (3)
Card 1 — Healey 2015 (SIMPLE): arrhythmic death or failed shock in 90 patients without testing versus 104 with (HR 0.86; noninferiority p<0.0001); 30-day safety composites 5.6% versus 6.5%
Study: Randomised single-blind non-inferiority trial (Healey 2015, SIMPLE)
Population: 2,500 patients older than 18 receiving their first ICD for standard indications at 85 hospitals in 18 countries (2009–2011), randomised to implantation with defibrillation testing (1,253) or without (1,247); mean follow-up 3.1 years. Right-sided implants and patients awaiting transplantation were excluded.
Summary: Healey 2015 (SIMPLE): arrhythmic death or failed shock in 90 patients without testing versus 104 with (HR 0.86; noninferiority p<0.0001); 30-day safety composites 5.6% versus 6.5%
Result: The primary outcome (arrhythmic death or failed appropriate shock) occurred in 90 patients in the no-testing group and 104 in the testing group (hazard ratio 0.86; 95% CI 0.65–1.14; p<0.0001 for noninferiority against a margin of 1.5). The first 30-day safety composite occurred in 69 patients (5.6%) without testing versus 81 (6.5%) with testing (p=0.33); the second composite, restricted to events most likely caused by testing itself, occurred in 3.2% versus 4.5% (p=0.08). Heart failure needing intravenous treatment was the most common adverse event in both groups (2% versus 2%).
Watch out: SIMPLE used one manufacturer's devices and excluded right-sided implants and some complex cases — the populations in which testing might still earn its keep. Noninferiority was declared against a generous hazard-ratio margin of 1.5, though the observed point estimate (0.86) favours omitting the test, so the margin is not what carries the conclusion.
Source: Healey JS et al. Cardioverter defibrillator implantation without induction of ventricular fibrillation: a single-blind, non-inferiority, randomised controlled trial (SIMPLE). The Lancet. 2015. PMID: 25715991. Registry ID: NCT00800384. MeSH: Arrhythmias, Cardiac/mortality/therapy · Defibrillators, Implantable · Electric Countershock/methods/mortality · Female · Heart Failure/etiology · Humans · Male · Middle Aged · Patient Safety · Postoperative Complications/etiology/mortality · Prognosis · Prosthesis Implantation/methods/mortality · Risk Assessment · Single-Blind Method · Ventricular Fibrillation/etiology
Card 2 — Bänsch 2015 (NORDIC ICD): first-shock efficacy difference +3.0% in favour of no testing (noninferiority p<0.001); procedure-related serious adverse events in 17.6% of tested versus 13.9% of untested patients
Study: Randomised trial (Bänsch 2015, NORDIC ICD)
Population: 1,077 patients randomised 1:1 (2011–2013) to first ICD implantation with (540) or without (537) standardised intra-operative defibrillation testing, all shocks programmed to 40 J regardless of test results; median follow-up 22.8 months.
Summary: Bänsch 2015 (NORDIC ICD): first-shock efficacy difference +3.0% in favour of no testing (noninferiority p<0.001); procedure-related serious adverse events in 17.6% of tested versus 13.9% of untested patients
Result: Model-based first-shock efficacy for true ventricular tachycardia/fibrillation episodes during follow-up was noninferior without testing, with a difference of 3.0% in favour of the no-test group (95% CI −3.0 to 9.0%; p for noninferiority <0.001 against a −10% margin). Within 30 days, 112 procedure-related serious adverse events occurred in 94 tested patients (17.6%) versus 89 events in 74 untested patients (13.9%) (p=0.095). The authors conclude defibrillation testing should no longer be recommended for routine left-sided ICD implantation.
Watch out: The serious-adverse-event gap (17.6% versus 13.9%) is not significant and counts all procedure-related events, not only test-caused ones; first-shock efficacy is a model-based average over episodes, so patients with many episodes weigh more. Both trials predate widespread subcutaneous and extravascular systems, where testing practice differs.
Source: Bänsch D et al. Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators: the NORDIC ICD randomized clinical trial. European Heart Journal. 2015. PMID: 26112885. MeSH: Defibrillators, Implantable/adverse effects/standards · Electric Countershock/adverse effects/standards · Female · Humans · Intraoperative Care/methods/mortality · Male · Middle Aged · Prospective Studies · Tachycardia/mortality/therapy · Treatment Outcome
Card 3 — Synthesis: two trials, 3,577 patients — the ritual test can be retired for routine first implants
Study: Synthesis
Population: Two randomised non-inferiority trials of omitting defibrillation testing at first ICD implant: SIMPLE (2,500 patients, clinical composite, 3.1-year mean follow-up) and NORDIC ICD (1,077 patients, first-shock efficacy, 22.8-month median follow-up).
Summary: Synthesis: two trials, 3,577 patients — the ritual test can be retired for routine first implants
Result: Arrhythmic death or failed shock: HR 0.86 favouring no testing (SIMPLE). First-shock efficacy: +3.0% favouring no testing (NORDIC ICD). Safety: no significant excess without testing in either trial; the only adverse-event gaps point against testing. POSSIBLE (the treatment made no difference).
Watch out: 'Routine' is the operative word — right-sided implants, congenital disease, and generator changes at high risk were excluded or scarce, and neither trial speaks to subcutaneous ICD testing, which follows a different logic. Tier C is not set: two concordant randomised trials carry the null.
Source: Synthesis of Healey JS et al. The Lancet. 2015 (PMID: 25715991); Bänsch D et al. European Heart Journal. 2015 (PMID: 26112885).