SourceMed · Shelf #3369 in the ask interface
His-bundle and physiologic pacing versus right-ventricular pacing: ejection fraction preserved (+5.3 points pooled) where RV pacing let it fall — mortality unchanged, heart-failure hospitalisation unmeasured in the pool
Shelf #3369 · Heart, vessels, blood pressure & clotting
POSSIBLE (benefit) — physiologic (His-bundle or biventricular) pacing preserved ejection fraction versus right-ventricular pacing in a guideline systematic review, with no mortality effect and no pooled hospitalisation data
Stamped: 2026-11-28.
Evidence published: 2018–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients who need ventricular pacing, does His-bundle pacing preserve ejection fraction and reduce heart-failure hospitalisation compared with right-ventricular pacing?
Balance of the evidence
POSSIBLE (benefit) — for the ventricle's measurements, not yet for its events. The systematic review prepared for the 2018 ACC/AHA/HRS bradycardia guideline (Slotwiner DJ et al., PMID: 30412708) pooled 8 studies and 679 patients with ejection fraction above 35% needing pacing for heart block: physiologic pacing — biventricular or His-bundle — left ventricular volumes lower (end-diastolic −2.77 mL; end-systolic −7.09 mL) and ejection fraction preserved or increased by 5.328 percentage points (95% CI 2.86–7.8; p<0.0001) compared with right-ventricular pacing over a mean ~1.6 years; there was no effect on mortality, data on hospitalisations were unavailable, and functional benefit was clearest in patients with chronic atrial fibrillation after AV-node ablation. The randomised His-SYNC pilot (Upadhyay GA et al., PMID: 31096064) compared His-bundle resynchronisation with biventricular pacing — not RV pacing — in 41 CRT patients: QRS narrowed far more on His pacing (125 versus 164 ms on-treatment; p<0.001) with a trend to more echocardiographic response (80% versus 57%; p=0.14) and no difference in cardiovascular hospitalisation or mortality, amid 48% crossover from the His arm. POSSIBLE (benefit): physiologic pacing protects the ejection fraction that RV pacing spends; whether that converts into fewer heart-failure admissions is, on this record, unmeasured rather than shown.
MeSH: Cardiac Pacing, Artificial/adverse effects/methods · Heart Block/therapy · Humans · Stroke Volume · Ventricular Remodeling
Cards (3)
Card 1 — Slotwiner 2019 (guideline systematic review): ejection fraction +5.328 points and volumes lower with physiologic versus RV pacing across 679 patients; mortality unaffected; hospitalisation data unavailable
Study: Systematic review and meta-analysis for the 2018 ACC/AHA/HRS guideline (Slotwiner 2019)
Population: 8 randomised and observational studies totalling 679 patients with left ventricular ejection fraction >35% requiring permanent pacing for heart block, comparing biventricular pacing or His-bundle pacing against right-ventricular pacing; mean follow-up ~1.6 years. Studies pooling patients above and below 35% ejection fraction could not be included because subset data were industry-held.
Summary: Slotwiner 2019 (guideline systematic review): ejection fraction +5.328 points and volumes lower with physiologic versus RV pacing across 679 patients; mortality unaffected; hospitalisation data unavailable
Result: With physiologic pacing (biventricular or His-bundle) versus right-ventricular pacing, left ventricular end-diastolic volume was lower by 2.77 mL (95% CI −4.37 to −1.1; p=0.001) and end-systolic volume by 7.09 mL (95% CI −11.27 to −2.91; p=0.0009), and ejection fraction remained preserved or increased by 5.328 percentage points (95% CI 2.86 to 7.8; p<0.0001). There was no effect on mortality; data on hospitalisations were unavailable; functional-status and quality-of-life data were not definitive. Benefit was more likely in patients with ejection fraction >35% but ≤52%, and patients with chronic atrial fibrillation who had AV-node ablation showed clear ejection-fraction improvement.
Watch out: The pool mixes His-bundle with biventricular pacing, mixes randomised with observational studies, and — remarkably — could not include larger mixed-EF studies because the subset data sit with industry; the hospitalisation half of this shelf's question is answered 'unavailable' by the review itself. An ejection-fraction difference of 5 points is a surrogate, however mechanistically satisfying.
Source: Slotwiner DJ et al. Impact of Physiologic Pacing Versus Right Ventricular Pacing Among Patients With Left Ventricular Ejection Fraction Greater Than 35%: A Systematic Review for the 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay. Journal of the American College of Cardiology. 2019. PMID: 30412708. MeSH: Cardiac Pacing, Artificial/adverse effects/methods · Heart Block/therapy · Humans · Stroke Volume · Ventricular Remodeling
Card 2 — Upadhyay 2019 (His-SYNC pilot, on-treatment): QRS 125 versus 164 ms (p<0.001) for His versus biventricular pacing; echo response 80% versus 57% (p=0.14); no difference in hospitalisation or mortality — 48% crossed over from His
Study: Randomised pilot trial, secondary on-treatment analysis (Upadhyay 2019, His-SYNC)
Population: 41 patients meeting standard CRT indications (NYHA class II–IV, QRS >120 ms; mean age 64, 38% women, ejection fraction 28%, QRS 168 ms), randomised at multiple centres to His-bundle cardiac resynchronisation (21) or biventricular resynchronisation (20), with prespecified crossover — required in 48% of the His arm (most often failure to correct QRS in nonspecific intraventricular conduction delay) and 26% of the biventricular arm.
Summary: Upadhyay 2019 (His-SYNC pilot, on-treatment): QRS 125 versus 164 ms (p<0.001) for His versus biventricular pacing; echo response 80% versus 57% (p=0.14); no difference in hospitalisation or mortality — 48% crossed over from His
Result: On treatment-received analysis, His-bundle pacing narrowed QRS more than biventricular pacing (125±22 ms versus 164±25 ms; p<0.001; per-protocol 124±19 versus 162±24 ms; p<0.001). Echocardiographic response trended higher with His pacing (80% versus 57% treatment-received, p=0.14; 91% versus 54% per-protocol, p=0.078). No significant differences in cardiovascular hospitalisation or mortality were observed.
Watch out: This card supports the mechanism, not the shelf's exact comparison: His-SYNC's comparator is biventricular pacing in a CRT (ejection fraction 28%) population, not right-ventricular pacing in bradycardia patients — and with 48% crossover, even its randomised contrast collapses into an on-treatment analysis of 41 patients. It is carded as supporting evidence and labelled as such.
Source: Upadhyay GA et al. On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial. Heart Rhythm. 2019. PMID: 31096064. MeSH: Bundle of His/physiopathology · Cardiac Resynchronization Therapy/adverse effects/methods · Cardiac Resynchronization Therapy Devices · Echocardiography/methods · Electrocardiography/methods · Female · Heart Failure/physiopathology/therapy · Heart Ventricles/physiopathology · Humans · Male · Middle Aged · Severity of Illness Index · Stroke Volume · Treatment Outcome
Card 3 — Synthesis: the wiring-sparing strategies protect the ejection fraction; the event ledger is blank
Study: Synthesis
Population: A guideline systematic review of physiologic versus right-ventricular pacing (8 studies, 679 patients, EF >35%) and one 41-patient randomised pilot of His-bundle versus biventricular resynchronisation (His-SYNC).
Summary: Synthesis: the wiring-sparing strategies protect the ejection fraction; the event ledger is blank
Result: Ejection fraction: +5.328 points pooled for physiologic versus RV pacing; LV volumes lower. Mortality: no effect. Heart-failure hospitalisation: unavailable in the pool; no difference in the pilot (against a biventricular comparator). QRS narrowing: markedly greater with His pacing. POSSIBLE (benefit), Tier C: surrogate-led evidence, hospitalisation unproven.
Watch out: A dedicated His-bundle-versus-RV randomised trial with clinical endpoints does not appear in this record; left-bundle-branch-area pacing, the technique that largely succeeded His pacing, is a different shelf's question (see live shelf #2300 for the resynchronisation comparison).
Source: Synthesis of Slotwiner DJ et al. Journal of the American College of Cardiology. 2019 (PMID: 30412708); Upadhyay GA et al. Heart Rhythm. 2019 (PMID: 31096064).