SourceMed · Shelf #3381 in the ask interface

FIT every year versus every two or three years: at the repeat round the detection of advanced neoplasia was the same whatever the interval — 1.9% overall, with no interval effect (p=0.62); mortality was never tested

Shelf #3381 · Cancer

POSSIBLE (the treatment made no difference) — single randomised interval comparison: advanced-neoplasia detection independent of 1–3-year interval (p=0.62); no mortality data

Stamped: 2026-11-28.

Evidence published: 2013.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In average-risk adults screened with faecal immunochemical testing, does annual testing detect more colorectal cancers and advanced adenomas than biennial testing, and does the interval change colorectal cancer mortality?

Balance of the evidence

POSSIBLE (the treatment made no difference) — for detection at the repeat round, within a 1–3-year range: in the Dutch randomised comparison of 7,501 invitees, second-round participation was 63.2% with a 1-year interval, 62.5% with 2 years and 64.0% with 3 years; positivity in the second round (6.0%, down from 8.4% in round one) did not depend on interval length (p=0.23), and neither did the detection rate of advanced neoplasia (1.9% in round two versus 3.3% in round one; interval comparison p=0.62). No trial has randomised the FIT interval and followed participants to colorectal cancer mortality, so that half of the question is unanswered by direct evidence. POSSIBLE (the treatment made no difference): annual testing finds no more advanced neoplasia at the repeat round than biennial or triennial testing; any mortality difference between intervals is untested, not disproven.

MeSH: Adenoma/diagnosis · Aged · Colorectal Neoplasms/diagnosis · Early Detection of Cancer/methods · Feces/chemistry · Follow-Up Studies · Hemoglobins/analysis · Humans · Immunochemistry · Mass Screening · Middle Aged · Occult Blood · Sensitivity and Specificity · Time Factors

Cards (2)

Card 1 — van Roon 2013: second-round advanced-neoplasia detection 1.9% overall and flat across 1-, 2- and 3-year intervals (p=0.62); participation 61–65% in every group

Study: Randomised population screening trial (van Roon 2013)

Population: 7,501 Dutch residents aged 50–74 randomly selected and invited for two rounds of one-sample FIT (cutoff 50 ng Hb/mL, 10 µg Hb/g faeces) separated by 1, 2 or 3 years.

Summary: van Roon 2013: second-round advanced-neoplasia detection 1.9% overall and flat across 1-, 2- and 3-year intervals (p=0.62); participation 61–65% in every group

Result: First-round participation was 64.7% (1-year group), 61.0% (2-year) and 62.0% (3-year); second-round participation was 63.2%, 62.5% and 64.0% respectively, with triennial screening drawing a higher second-round participation than annual (p=0.04). Second-round positivity was 6.0% versus 8.4% in round one (OR 0.69, 95% CI 0.58–0.82) and did not depend on interval (p=0.23); advanced-neoplasia detection was 1.9% in round two versus 3.3% in round one (OR 0.57, 95% CI 0.43–0.76), likewise independent of interval (p=0.62). Positive predictive value was 41% versus 33% (p=0.07).

Watch out: Only two rounds and a detection endpoint: the trial cannot speak to cumulative cancers found over a decade of annual versus biennial testing, interval cancers, or mortality — and its cutoff (10 µg/g) is lower than many programmes now use.

Source: van Roon AH et al. Random comparison of repeated faecal immunochemical testing at different intervals for population-based colorectal cancer screening. Gut. 2013. PMID: 22387523. MeSH: Adenoma/diagnosis · Aged · Colorectal Neoplasms/diagnosis · Early Detection of Cancer/methods · Feces/chemistry · Follow-Up Studies · Hemoglobins/analysis · Humans · Immunochemistry · Mass Screening · Middle Aged · Occult Blood · Sensitivity and Specificity · Time Factors

Card 2 — Synthesis: interval length within 1–3 years does not change what the next FIT round finds — the mortality question has no randomised answer

Study: Synthesis

Population: One randomised population trial (n=7,501) directly comparing FIT intervals on participation and detection.

Summary: Synthesis: interval length within 1–3 years does not change what the next FIT round finds — the mortality question has no randomised answer

Result: Advanced neoplasia at round two: 1.9% overall, no interval dependence (p=0.62). Participation: ~61–65% in all groups. Colorectal cancer mortality by interval: no randomised data. POSSIBLE (the treatment made no difference) for detection, Tier C because a single trial carries the shelf and the mortality half of the question is untested.

Watch out: Programmes choosing annual testing are buying more rounds over a lifetime, not a better yield per round; modelling studies, not trials, are what support any long-term difference.

Source: Synthesis of van Roon AH et al. Gut. 2013 (PMID: 22387523).