SourceMed · Shelf #3405 in the ask interface

Sentinel-node mapping in endometrial cancer: sensitivity 97.2% and negative predictive value 99.6% in FIRES, with a 97% per-patient negative predictive value in SENTI-ENDO

Shelf #3405 · Cancer

POSSIBLE (benefit) — sentinel-node mapping detected node-positive disease with 97.2% sensitivity and 99.6% negative predictive value in FIRES, corroborated by SENTI-ENDO, in prospective diagnostic cohorts

Stamped: 2026-11-28.

Evidence published: 2011–2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In women with apparent early-stage endometrial cancer, does sentinel-lymph-node mapping stage the cancer as accurately as full lymphadenectomy?

Balance of the evidence

POSSIBLE (benefit) — for staging accuracy, from two prospective diagnostic cohorts checked against the full dissection they would replace. In FIRES (Rossi EC et al., PMID: 28159465), 340 women with clinical stage 1 endometrial cancer had indocyanine-green sentinel-node mapping followed by complete pelvic lymphadenectomy: of 36 node-positive patients with successful mapping, the sentinel node caught 35 — sensitivity 97.2% (95% CI 85.0–100) and negative predictive value 99.6% (97.9–100). In SENTI-ENDO (Ballester M et al., PMID: 21489874), dual-label mapping in 111 women gave a per-patient negative predictive value of 97% (91–99) and sensitivity of 84% (62–95), with all three false negatives in type 2 cancers; ultrastaging found metastases conventional histology missed in 47% of node-positive patients. POSSIBLE (benefit): mapping stages accurately enough to spare most women a full lymphadenectomy, on prospective cohort — not randomised — evidence.

MeSH: Adenocarcinoma, Clear Cell/diagnostic imaging/pathology/surgery · Adult · Aged · Aged, 80 and over · Carcinosarcoma/diagnostic imaging/pathology/surgery · Coloring Agents · Cystadenocarcinoma, Serous/diagnostic imaging/pathology/surgery · Endometrial Neoplasms/diagnostic imaging/pathology/surgery · Female · Follow-Up Studies · Humans · Indocyanine Green · Lymph Node Excision/methods · Middle Aged · Neoplasm Grading · Neoplasm Staging · Prognosis · Prospective Studies · Sentinel Lymph Node/diagnostic imaging/pathology/surgery · Sentinel Lymph Node Biopsy/methods

Cards (3)

Card 1 — Rossi 2017 (FIRES): sentinel nodes caught 35 of 36 node-positive patients — sensitivity 97.2%, negative predictive value 99.6%, mapping succeeded in 86%

Study: Prospective multicentre diagnostic-accuracy cohort study (Rossi 2017, FIRES)

Population: 385 women enrolled (340 analysed) with clinical stage 1 endometrial cancer of all histologies and grades undergoing robotic staging at 10 US centres: cervical indocyanine-green injection and sentinel-node mapping, then complete pelvic lymphadenectomy (para-aortic in 58%); negative sentinel nodes were ultrastaged with cytokeratin immunohistochemistry.

Summary: Rossi 2017 (FIRES): sentinel nodes caught 35 of 36 node-positive patients — sensitivity 97.2%, negative predictive value 99.6%, mapping succeeded in 86%

Result: Successful mapping of at least one sentinel node in 293 of 340 patients (86%). Forty-one patients (12%) had positive nodes; among the 36 node-positive patients with successful mapping, sentinel nodes identified metastases in 35 (97%) — sensitivity 97.2% (95% CI 85.0–100) and negative predictive value 99.6% (97.9–100). The commonest grade 3–4 events were postoperative neurological disorders (4 patients) and respiratory distress or failure (4 patients); 22 patients had serious adverse events, one (a ureteral injury during sentinel-node dissection) related to the study intervention.

Watch out: A diagnostic-accuracy study, not a treatment trial: it shows mapping finds the metastases, not that omitting lymphadenectomy leaves survival unchanged — the 3% of node-positive patients missed are the honest price printed on the record. Mapping failed entirely in 14% of patients, who still need a backup plan.

Source: Rossi EC et al. A comparison of sentinel lymph node biopsy to lymphadenectomy for endometrial cancer staging (FIRES trial): a multicentre, prospective, cohort study. The Lancet Oncology. 2017. PMID: 28159465. Registry ID: NCT01673022. MeSH: Adenocarcinoma, Clear Cell/diagnostic imaging/pathology/surgery · Adult · Aged · Aged, 80 and over · Carcinosarcoma/diagnostic imaging/pathology/surgery · Coloring Agents · Cystadenocarcinoma, Serous/diagnostic imaging/pathology/surgery · Endometrial Neoplasms/diagnostic imaging/pathology/surgery · Female · Follow-Up Studies · Humans · Indocyanine Green · Lymph Node Excision/methods · Middle Aged · Neoplasm Grading · Neoplasm Staging · Prognosis · Prospective Studies · Sentinel Lymph Node/diagnostic imaging/pathology/surgery · Sentinel Lymph Node Biopsy/methods

Card 2 — Ballester 2011 (SENTI-ENDO): per-hemipelvis negative predictive value 100%, but per-patient sensitivity 84% — all three false negatives were type 2 cancers

Study: Prospective multicentre diagnostic-accuracy cohort study (Ballester 2011, SENTI-ENDO)

Population: 133 women with FIGO stage I–II endometrial cancer at nine French centres: cervical dual injection (technetium colloid and patent blue) for pelvic sentinel-node assessment, then systematic pelvic-node dissection, with serial sectioning and immunohistochemistry of sentinel nodes.

Summary: Ballester 2011 (SENTI-ENDO): per-hemipelvis negative predictive value 100%, but per-patient sensitivity 84% — all three false negatives were type 2 cancers

Result: At least one sentinel node was detected in 111 of 125 eligible patients; 19 of 111 (17%) had pelvic-node metastases. Per hemipelvis, negative predictive value was 100% (95% CI 95–100) and sensitivity 100% (63–100). Per patient, three false negatives (two contralateral pelvic, one para-aortic) gave a negative predictive value of 97% (95% CI 91–99) and sensitivity of 84% (62–95) — all three in type 2 endometrial cancer. Immunohistochemistry and serial sectioning detected metastases missed by conventional histology in 9 of 111 patients (8%), representing 9 of the 19 (47%) with metastases; sentinel biopsy upstaged 10% of low-risk and 15% of intermediate-risk patients. No injection complications or anaphylactic reactions occurred.

Watch out: The older dual-label technique and the per-patient framing give the less flattering numbers, and the type 2 concentration of false negatives matters: mapping accuracy is histology-dependent. Like FIRES, this is accuracy against dissection, not a survival comparison.

Source: Ballester M et al. Detection rate and diagnostic accuracy of sentinel-node biopsy in early stage endometrial cancer: a prospective multicentre study (SENTI-ENDO). The Lancet Oncology. 2011. PMID: 21489874. Registry ID: NCT00987051. MeSH: Adult · Aged · Aged, 80 and over · Coloring Agents · Diagnosis, Differential · Endometrial Neoplasms/pathology/surgery · Female · Humans · Lymph Node Excision · Lymph Nodes/pathology/surgery · Lymphatic Metastasis · Middle Aged · Neoplasm Staging · Prospective Studies · Radiopharmaceuticals · Risk Factors · Rosaniline Dyes · Sentinel Lymph Node Biopsy/methods · Technetium Tc 99m Sulfur Colloid

Card 3 — Synthesis: two prospective cohorts agree mapping finds nearly all nodal disease — the residual miss rate and type 2 caveat ride along

Study: Synthesis

Population: Two prospective multicentre diagnostic cohorts (FIRES n=340 with indocyanine green; SENTI-ENDO n=111 analysed with dual labelling), each verifying sentinel-node results against systematic pelvic lymphadenectomy.

Summary: Synthesis: two prospective cohorts agree mapping finds nearly all nodal disease — the residual miss rate and type 2 caveat ride along

Result: Sensitivity 97.2% and negative predictive value 99.6% (FIRES, per protocol); per-patient sensitivity 84% and negative predictive value 97% (SENTI-ENDO), with ultrastaging adding metastases in about half of node-positive patients in SENTI-ENDO. POSSIBLE (benefit), Tier C: diagnostic cohort evidence without a randomised survival comparison is developer-review material.

Watch out: Neither study randomises women to mapping versus dissection and follows survival — the inference that spared lymphadenectomies cost nothing oncologically rests on the very low false-negative rates, and FIRES’ own framing (a 3% miss among node-positive patients) is the number to quote, not zero.

Source: Synthesis of Rossi EC et al. The Lancet Oncology. 2017 (PMID: 28159465); Ballester M et al. The Lancet Oncology. 2011 (PMID: 21489874).