SourceMed · Shelf #3529 in the ask interface
Patient self-titration of basal insulin (AT.LANTUS): HbA1c fell 1.22% versus 1.08% with physician-led titration in 4,961 patients — severe hypoglycaemia 1.1% versus 0.9%
Shelf #3529 · Diabetes, glucose & metabolism
POSSIBLE (benefit) — patient self-titration of glargine achieved slightly greater HbA1c and fasting-glucose reductions than physician-led titration with no significant difference in severe hypoglycaemia, in one 4,961-patient trial
Stamped: 2026-11-28.
Evidence published: 2005.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In type 2 diabetes starting basal insulin, does a simple patient self-titration algorithm achieve control as safely as physician-led titration?
Balance of the evidence
POSSIBLE (benefit) — patients titrating their own glargine did at least as well as physicians, in one very large pragmatic trial. AT.LANTUS (Davies M et al., PMID: 15920040) randomised 4,961 people with poorly controlled type 2 diabetes (72% already on insulin, mean duration 12.3 years) to investigator-led titration or a simple subject-administered algorithm for 24 weeks. HbA1c fell from 8.9% to 7.8% overall, with a significantly greater decrease on self-titration (−1.22% versus −1.08%, P<0.001) and a greater fasting glucose fall (−62 versus −57 mg/dL, P<0.001); self-titrators also ended on a higher mean dose increase (21.6 versus 18.7 IU, P<0.003). Severe hypoglycaemia was uncommon and not significantly different: 1.1% self-titration versus 0.9% investigator-led. POSSIBLE (benefit): a simple self-titration algorithm is safe and marginally more effective than physician-led titration — a single (though very large) open-label trial, so.
MeSH: Algorithms · Blood Glucose · Body Mass Index · Diabetes Mellitus, Type 2 · Female · Humans · Hypoglycemic Agents · Insulin · Insulin Glargine · Insulin, Long-Acting · Male · Middle Aged · Patient Selection · Safety · Treatment Outcome
Cards (2)
Card 1 — AT.LANTUS (Davies 2005): self-titration −1.22% HbA1c versus −1.08% physician-led (P<0.001); severe hypoglycaemia 1.1% versus 0.9% in 4,961 patients
Study: Randomised pragmatic trial (Davies 2005, AT.LANTUS)
Population: 4,961 subjects with suboptimally controlled type 2 diabetes (mean duration 12.3 years, 72% pretreated with insulin, baseline HbA1c 8.9%) at 611 centres in 59 countries, randomised to insulin glargine initiation and titration by algorithm 1 (investigator-led, n=2,493) or algorithm 2 (performed by the study subjects, n=2,468) for 24 weeks, open-label.
Summary: AT.LANTUS (Davies 2005): self-titration −1.22% HbA1c versus −1.08% physician-led (P<0.001); severe hypoglycaemia 1.1% versus 0.9% in 4,961 patients
Result: HbA1c fell from 8.9 ± 1.3% to 7.8 ± 1.2%, with a greater decrease on self-titration (−1.22%) than investigator-led titration (−1.08%, P<0.001). Fasting blood glucose fell from 170 to 110 mg/dL, again more with self-titration (−62 versus −57 mg/dL, P<0.001). Mean basal dose rose from 22.9 ± 15.5 to 43.0 ± 25.5 IU, with a larger increase in the self-titration group (21.6 versus 18.7 IU, P<0.003). Severe hypoglycaemia incidence did not differ significantly: 0.9% (investigator-led) versus 1.1% (self-titration).
Watch out: Open-label and industry-era (2005, glargine U100): the self-titration advantage is small in absolute terms (0.14% HbA1c) and partly explained by patients simply taking more insulin (a 2.9 IU larger dose increase) — the algorithm works by removing physician caution, which is also its risk in less-selected real-world patients.
Source: Davies M et al. Improvement of glycemic control in subjects with poorly controlled type 2 diabetes: comparison of two treatment algorithms using insulin glargine. Diabetes care. 2005. PMID: 15920040. MeSH: Algorithms · Blood Glucose · Body Mass Index · Diabetes Mellitus, Type 2 · Female · Humans · Hypoglycemic Agents · Insulin · Insulin Glargine · Insulin, Long-Acting · Male · Middle Aged · Patient Selection · Safety · Treatment Outcome
Card 2 — Synthesis: one very large trial — self-titration is safe and slightly more effective, because patients titrate further
Study: Synthesis
Population: One multinational open-label randomised trial of 4,961 patients with longstanding, poorly controlled type 2 diabetes, 24 weeks.
Summary: Synthesis: one very large trial — self-titration is safe and slightly more effective, because patients titrate further
Result: HbA1c −1.22% (self) versus −1.08% (physician); fasting glucose −62 versus −57 mg/dL; final dose increase 21.6 versus 18.7 IU; severe hypoglycaemia 1.1% versus 0.9% (not significant). POSSIBLE (benefit), Tier C: a single trial carries the shelf, albeit an unusually large and pragmatic one.
Watch out: The comparison is of titration behaviour, not of a drug: results from 2005 with glargine U100 and clinic-supported patients may not transfer to unsupervised settings, newer basal insulins, or patients with hypoglycaemia unawareness — none of whom this trial isolates.
Source: Synthesis of Davies M et al. Diabetes care. 2005 (PMID: 15920040).