Sensor-augmented pump versus injections in type 1 diabetes: HbA1c 7.5% versus 8.1% at one year in STAR 3 — in adults and children alike, with no difference in severe hypoglycaemia
Shelf #3568 · Diabetes, glucose & metabolism
POSSIBLE (benefit) — STAR 3: HbA1c 7.5% versus 8.1% at 1 year (P<0.001), severe hypoglycaemia unchanged; single trial programme, Tier C
Stamped: 2026-11-28.
Evidence published: 2010–2015.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In type 1 diabetes with suboptimal control, does sensor-augmented pump therapy lower HbA1c more than multiple daily injections with fingerstick monitoring?
Balance of the evidence
POSSIBLE (benefit) — one large, well-run trial, unblinded by necessity. In STAR 3 (485 patients — 329 adults and 156 children — with inadequately controlled type 1 diabetes, baseline HbA1c 8.3% in both groups), sensor-augmented pump therapy brought HbA1c to 7.5% at 1 year versus 8.1% with multiple daily injections plus fingerstick monitoring (P<0.001), and a greater proportion of both adults and children reached the below-7% target on the pump. Severe hypoglycaemia did not differ (13.31 versus 13.48 events per 100 person-years, P=0.58), and neither group gained significant weight. A post hoc analysis of the North American cohort found the incremental pump benefit similar in the United States (−0.93% versus −0.31% A1C change, pump versus injections) and Canada (−1.14% versus −0.67%), alongside higher sensor use in Canada (79% versus 68% of the time). POSSIBLE (benefit): sensor-augmented pump therapy lowers HbA1c by about 0.6 points more than injections over a year. Tier C is set because the benefit rests on a single trial programme — its post hoc analyses are the same patients, not independent confirmation.
MeSH: Adolescent · Adult · Analysis of Variance · Child · Diabetes Mellitus, Type 1/blood/drug therapy · Diabetic Ketoacidosis/etiology · Female · Glycated Hemoglobin/analysis · Humans · Hypoglycemia/chemically induced/prevention & control · Injections, Subcutaneous · Insulin/administration & dosage/adverse effects · Insulin Infusion Systems · Male · Middle Aged · Monitoring, Ambulatory · Treatment Outcome · Young Adult
Cards (3)
Card 1 — Bergenstal 2010 (STAR 3): HbA1c fell to 7.5% on sensor-augmented pump versus 8.1% on injections at 1 year (P<0.001); severe hypoglycaemia 13.31 versus 13.48 per 100 person-years (P=0.58)
Study: Randomised controlled trial (Bergenstal 2010, STAR 3)
Population: 485 patients with inadequately controlled type 1 diabetes (329 adults, 156 children; baseline mean HbA1c 8.3% in both groups) at multiple centres, randomised to sensor-augmented pump therapy or multiple daily injections with fingerstick monitoring for 1 year, all using recombinant insulin analogues under expert clinical teams.
Summary: Bergenstal 2010 (STAR 3): HbA1c fell to 7.5% on sensor-augmented pump versus 8.1% on injections at 1 year (P<0.001); severe hypoglycaemia 13.31 versus 13.48 per 100 person-years (P=0.58)
Result: At 1 year, mean HbA1c was 7.5% in the pump-therapy group versus 8.1% in the injection-therapy group (P<0.001), and a significantly greater proportion of both adults and children in the pump group reached the HbA1c target of below 7%. The rate of severe hypoglycaemia did not differ significantly (13.31 versus 13.48 cases per 100 person-years, P=0.58), and there was no significant weight gain in either group.
Watch out: Open-label technology trial run by expert teams with structured support: the comparison bundles the sensor, the pump and the attention together, and usual-care clinics should not expect the full 0.6-point advantage without the same support. One trial, however large, is one trial.
Source: Bergenstal RM et al. Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. The New England journal of medicine. 2010. PMID: 20587585. Registry ID: NCT00417989. MeSH: Adolescent · Adult · Analysis of Variance · Child · Diabetes Mellitus, Type 1/blood/drug therapy · Diabetic Ketoacidosis/etiology · Female · Glycated Hemoglobin/analysis · Humans · Hypoglycemia/chemically induced/prevention & control · Injections, Subcutaneous · Insulin/administration & dosage/adverse effects · Insulin Infusion Systems · Male · Middle Aged · Monitoring, Ambulatory · Treatment Outcome · Young Adult
Card 2 — Perkins 2015 (STAR 3, US/Canada post hoc): pump advantage consistent across both health systems (−0.93 versus −0.31 A1C change in the US; −1.14 versus −0.67 in Canada)
Study: Post hoc analysis of a randomised trial (Perkins 2015, STAR 3)
Population: The 329 adults of STAR 3 treated at 26 US sites (n=271) and 4 Canadian sites (n=58), randomised to sensor-augmented pump or glargine-based multiple daily injections, comparing baseline to 1-year A1C change by country.
Summary: Perkins 2015 (STAR 3, US/Canada post hoc): pump advantage consistent across both health systems (−0.93 versus −0.31 A1C change in the US; −1.14 versus −0.67 in Canada)
Result: Canadian participants had greater A1C reductions overall (P=0.02), but the incremental benefit of sensor-augmented pump therapy was similar in the US (pump −0.93%±0.73% versus injections −0.31%±0.81%, P<0.001) and in Canada (−1.14%±0.72% versus −0.67%±0.71%, P<0.001). Mean sensor use was higher in Canada (79% versus 68% of the time, P<0.001).
Watch out: A post hoc slice of the same trial — it tests generalisability across two similar health systems, not the treatment effect itself, and it covers adults only, whereas the main trial's paediatric result rests on its 156 children.
Source: Perkins BA et al. Sensor-augmented pump and multiple daily injection therapy in the United States and Canada: post-hoc analysis of a randomized controlled trial. Canadian journal of diabetes. 2015. PMID: 25175313. Registry ID: NCT00417989. MeSH: Adolescent · Adult · Aged · Canada · Child · Diabetes Mellitus, Type 1/drug therapy · Female · Glycated Hemoglobin/metabolism · Humans · Injections · Insulin/administration & dosage/therapeutic use · Insulin Infusion Systems · Male · Middle Aged · Socioeconomic Factors · Treatment Outcome · United States
Card 3 — Synthesis: a 0.6-point HbA1c advantage for sensor-augmented pumping over a year, hypoglycaemia unchanged
Study: Synthesis
Population: One 485-patient randomised trial (adults and children, 1 year) and its North American post hoc analysis (329 adults).
Summary: Synthesis: a 0.6-point HbA1c advantage for sensor-augmented pumping over a year, hypoglycaemia unchanged
Result: HbA1c at 1 year: 7.5% versus 8.1% (P<0.001). Severe hypoglycaemia: 13.31 versus 13.48 per 100 person-years (P=0.58). Target attainment (HbA1c <7%): significantly more patients on pump therapy in both age groups. POSSIBLE (benefit).
Watch out: Hybrid closed-loop systems — which automate insulin delivery rather than merely sensing and pumping — answer a different question and live on their own shelf (#561); this shelf is the pre-automation sensor-augmented comparison. Tier C is set: single trial programme.
Source: Synthesis of Bergenstal RM et al. The New England Journal of Medicine. 2010 (PMID: 20587585); Perkins BA et al. Canadian Journal of Diabetes. 2015 (PMID: 25175313).