SourceMed · Shelf #3611 in the ask interface

Metal versus plastic stents for malignant biliary obstruction: metal stays patent far longer (hazard ratio 0.36), needs fewer re-interventions, and pooled survival favoured metal (HR 0.74) across 10 randomised trials

Shelf #3611 · Liver & gut

POSSIBLE (benefit) — meta-analysis of 10 RCTs: metal stents longer patency (HR 0.36), fewer re-interventions, longer survival (HR 0.74) vs plastic stents

Stamped: 2026-11-28.

Evidence published: 2013.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In malignant biliary obstruction, do self-expandable metal stents stay patent longer than plastic stents — and at what cost in complications?

Balance of the evidence

POSSIBLE (benefit) — patency decisively, survival modestly, in trial populations. Hong's updated meta-analysis of 10 randomised trials found metal stents associated with significantly longer stent patency than plastic stents (hazard ratio 0.36, 95% CI 0.28–0.47, I²=0%), fewer re-interventions (weighted mean difference 0.59, 95% CI 0.28–0.90) and longer patient survival (HR 0.74, 95% CI 0.64–0.85, I²=16.0%); results held in sensitivity analyses, and no publication bias was observed. The one soft spot: in the hilar-obstruction subgroup, the re-intervention advantage did not reach significance. The record reports no pooled complication penalty against metal to set against these gains — but it also predates much of the covered-versus-uncovered metal stent refinement. POSSIBLE (benefit): for palliation of malignant biliary obstruction, metal stents outlast plastic, spare re-interventions and were associated with longer survival; Tier C because the shelf carries a mortality benefit claim.

MeSH: Bile Duct Neoplasms/complications/mortality · Cholestasis/etiology/mortality/therapy · Drainage/instrumentation · Humans · Metals · Palliative Care · Plastics · Randomized Controlled Trials as Topic · Stents

Cards (2)

Card 1 — Hong 2013 updated meta-analysis (10 RCTs): patency HR 0.36 (0.28–0.47), survival HR 0.74 (0.64–0.85), re-interventions fewer by WMD 0.59

Study: Meta-analysis of randomised trials (Hong 2013)

Population: Ten randomised clinical trials comparing self-expandable metal stents with plastic stents for palliation of malignant biliary obstruction, with subgroup analysis by distal versus hilar obstruction; endpoints were stent patency, re-intervention rate and patient survival.

Summary: Hong 2013 updated meta-analysis (10 RCTs): patency HR 0.36 (0.28–0.47), survival HR 0.74 (0.64–0.85), re-interventions fewer by WMD 0.59

Result: Metal stents were associated with significantly longer stent patency (hazard ratio 0.36, 95% CI 0.28–0.47; I²=0%), fewer re-interventions (weighted mean difference 0.59, 95% CI 0.28–0.90; I²=76.4%) and longer patient survival (HR 0.74, 95% CI 0.64–0.85; I²=16.0%) than plastic stents. All results remained significant in sensitivity analysis except the pooled re-intervention difference in the hilar-obstruction studies. No publication bias was observed.

Watch out: A survival advantage from a stent is biologically indirect — plausibly mediated by fewer occlusions, infections and re-interventions — and the re-intervention pooling is highly heterogeneous (I²=76.4%). The 2013 search also predates later covered-metal and hilar-drainage trials. Mortality benefit claim: Tier C by the standing rules.

Source: Hong WD et al. Metal versus plastic stents for malignant biliary obstruction: An update meta-analysis. Clinics and Research in Hepatology and Gastroenterology. 2013. PMID: 23333231. MeSH: Bile Duct Neoplasms/complications/mortality · Cholestasis/etiology/mortality/therapy · Drainage/instrumentation · Humans · Metals · Palliative Care · Plastics · Randomized Controlled Trials as Topic · Stents

Card 2 — Synthesis: patency is the proven win; survival rides along in the pooled trials

Study: Synthesis

Population: One updated meta-analysis of 10 randomised trials of metal versus plastic stents for malignant biliary obstruction.

Summary: Synthesis: patency is the proven win; survival rides along in the pooled trials

Result: Patency HR 0.36 (95% CI 0.28–0.47), re-interventions fewer (WMD 0.59, 95% CI 0.28–0.90), survival HR 0.74 (95% CI 0.64–0.85), all favouring metal stents; hilar re-intervention subgroup not significant. POSSIBLE (benefit), Tier C for the mortality claim.

Watch out: Cost runs the other way — metal stents are far more expensive up front — and neither this record nor the shelf prices the trade; for patients with very short expected survival, the patency advantage may never be cashed in. That judgement stays with the treating team.

Source: Synthesis of Hong WD et al. Clinics and Research in Hepatology and Gastroenterology. 2013 (PMID: 23333231).