SourceMed · Shelf #3655 in the ask interface
Shunt valves in normal-pressure hydrocephalus: starting pressure and valve design changed overdrainage complications — 5 versus 29 cases in SVASONA — but not who improved
Shelf #3655 · Brain, stroke & mind
SPLIT — initial pressure setting and valve design changed overdrainage complications (fewer effusions starting high; 5 versus 29 overdrainage cases with gravitational valves) but did not change clinical improvement or disease-specific outcome
Stamped: 2026-11-28.
Evidence published: 2013.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In idiopathic normal-pressure hydrocephalus, do shunt-valve pressure settings change gait and clinical outcome after ventriculoperitoneal shunting?
Balance of the evidence
SPLIT — valve choices move overdrainage complications, not clinical improvement. In the DEPSS trial (58 patients with suspected idiopathic normal-pressure hydrocephalus), an adjustable Strata valve preset at the highest performance level (2.5, lowered stepwise) produced no statistically significant difference in clinical improvement versus a valve preset low (performance level 1.0), but significantly more subdural effusions were observed in the improved patients in the low-preset group — the authors recommend starting high and lowering until improvement or radiological overdrainage appears, accepting slower improvement and more adjustments. The companion valve trial, SVASONA (145 patients), compared gravitational with programmable valves: overdrainage signs at 6 months occurred in 5 patients on gravitational valves versus 29 on standard valves (risk difference −36%, 95% CI −49% to −23%; p<0.001 — about one overdrainage complication avoided for every third patient), while disease-specific outcome scales did not differ between groups. SPLIT: start-high/valve-design strategies cut overdrainage harm; neither trial showed better gait or disease-specific clinical outcome from the valve choice itself.
MeSH: Data Interpretation, Statistical · Equipment Design · Equipment Failure · Follow-Up Studies · Gait Disorders, Neurologic/etiology/physiopathology · Humans · Hydrocephalus, Normal Pressure/therapy · Nervous System Diseases/epidemiology/etiology · Netherlands · Pressure · Prospective Studies · Subdural Effusion/epidemiology/etiology · Treatment Outcome · Ventriculoperitoneal Shunt/instrumentation
Cards (3)
Card 1 — DEPSS (Delwel 2013): high preset (PL 2.5, lowered stepwise) versus low preset (PL 1.0) — improvement did not differ significantly, subdural effusions clustered in the low-preset improvers
Study: Randomised multicentre trial (Delwel 2013, DEPSS)
Population: 58 patients with suspected idiopathic normal-pressure hydrocephalus in a Dutch multicentre prospective randomised trial: 30 assigned to a Strata shunt (Medtronic) with the adjustable valve preset at performance level 1.0 (control), and 28 to the same valve preset at performance level 2.5, with the level allowed to be lowered until clinical improvement or radiological signs of overdrainage occurred.
Summary: DEPSS (Delwel 2013): high preset (PL 2.5, lowered stepwise) versus low preset (PL 1.0) — improvement did not differ significantly, subdural effusions clustered in the low-preset improvers
Result: There was no statistically significant difference in improvement between the two groups overall. Significantly more subdural effusions were observed in the improved patients of the low-preset (PL 1.0) group. The authors recommend treating INPH with an adjustable valve preset at the highest opening pressure, lowered until clinical improvement or radiological signs of overdrainage occur, although slower improvement and more shunt adjustments might be the consequence. The record's abstract reports no event counts or effect sizes for the effusion comparison, so none are carded.
Watch out: A 58-patient trial whose abstract gives the effusion result only as 'significantly more' in a subgroup (improved patients) — the least robust form of reporting, with no counts to audit. Enrolment was of patients 'suspected' of INPH, a diagnostically uncertain population in whom shunt response itself varies, so a null on improvement may reflect case mix as much as valve physics.
Source: Delwel EJ et al. A randomised trial of high and low pressure level settings on an adjustable ventriculoperitoneal shunt valve for idiopathic normal pressure hydrocephalus: results of the Dutch evaluation programme Strata shunt (DEPSS) trial. Journal of Neurology, Neurosurgery, and Psychiatry. 2013. PMID: 23408069. MeSH: Data Interpretation, Statistical · Equipment Design · Equipment Failure · Follow-Up Studies · Gait Disorders, Neurologic/etiology/physiopathology · Humans · Hydrocephalus, Normal Pressure/therapy · Nervous System Diseases/epidemiology/etiology · Netherlands · Pressure · Prospective Studies · Subdural Effusion/epidemiology/etiology · Treatment Outcome · Ventriculoperitoneal Shunt/instrumentation
Card 2 — SVASONA (Lemcke 2013): overdrainage at 6 months in 5 patients on gravitational valves versus 29 on programmable valves (risk difference −36%, p<0.001) — disease-specific outcomes did not differ
Study: Randomised pragmatic open-label multicentre trial (Lemcke 2013, SVASONA)
Population: 145 patients with idiopathic normal-pressure hydrocephalus eligible for ventriculoperitoneal shunting (mean age 71.9 years, SD 6.9), enrolled in a pragmatic randomised open-label multicentre trial of gravitational valves versus non-gravitational programmable valves; 137 were available for endpoint analysis at 6 months.
Summary: SVASONA (Lemcke 2013): overdrainage at 6 months in 5 patients on gravitational valves versus 29 on programmable valves (risk difference −36%, p<0.001) — disease-specific outcomes did not differ
Result: The primary endpoint — any clinical or radiological sign of overdrainage (headache, nausea, vomiting, subdural effusion or slit ventricle) at 6 months — occurred in 29 patients in the standard-valve group and 5 in the gravitational-valve group (risk difference −36%, 95% CI −49% to −23%; p<0.001), a difference that exceeded predetermined stopping rules and stopped recruitment early; implanting a gravitational valve avoids one additional overdrainage complication in about every third patient shunted. Disease-specific outcome scales (Black and Kiefer) did not differ between groups, although the SF-12 Mental Component Score favoured the gravitational device at 6 and 12 months.
Watch out: Open-label with a partly clinical primary endpoint (headache, nausea) that knowledge of the valve could influence, and stopped early for benefit — early stopping on a large effect tends to overstate it. It answers a valve-design question (gravitational versus programmable), not the DEPSS pressure-setting question; it is carded as the companion evidence that overdrainage, not efficacy, is what valve choices move.
Source: Lemcke J et al. Safety and efficacy of gravitational shunt valves in patients with idiopathic normal pressure hydrocephalus: a pragmatic, randomised, open label, multicentre trial (SVASONA). Journal of Neurology, Neurosurgery, and Psychiatry. 2013. PMID: 23457222. Registry ID: ISRCTN51046698. MeSH: Adult · Aged · Aged, 80 and over · Cerebrospinal Fluid Shunts/adverse effects · Endpoint Determination · Equipment Design · Female · Follow-Up Studies · Gait Disorders, Neurologic/etiology/surgery · Gravitation · Humans · Hydrocephalus/complications/surgery · Hydrocephalus, Normal Pressure/psychology/surgery · Magnetic Resonance Imaging · Male · Middle Aged · Netherlands · Tomography, X-Ray Computed
Card 3 — Synthesis: two 2013 valve trials agree — settings and designs change overdrainage, not who improves
Study: Synthesis
Population: Two randomised multicentre trials in idiopathic normal-pressure hydrocephalus from 2013: DEPSS (58 patients, high versus low initial pressure setting on an adjustable valve) and SVASONA (145 patients, gravitational versus programmable valve).
Summary: Synthesis: two 2013 valve trials agree — settings and designs change overdrainage, not who improves
Result: Clinical improvement / disease-specific outcome: no significant difference in either trial. Overdrainage harm: significantly more subdural effusions among improvers on the low-preset strategy (DEPSS, no counts in the record), and 5 versus 29 patients with overdrainage signs at 6 months favouring gravitational valves (risk difference −36%, 95% CI −49% to −23%; p<0.001; SVASONA). SPLIT, with the complication benefit and the efficacy null both on the face of the shelf. Tier C is set: the complication claim rests on one small trial with uncounted events and one open-label trial stopped early.
Watch out: Neither trial was blinded, samples are small, and the two interventions (initial pressure setting; valve mechanism) are cousins, not twins — the synthesis claims agreement on the pattern (harm moves, efficacy does not), not a pooled estimate. A later generation of valves and the question of shunting itself are different shelves.
Source: Synthesis of Delwel EJ et al. Journal of Neurology, Neurosurgery, and Psychiatry. 2013 (PMID: 23408069); Lemcke J et al. Journal of Neurology, Neurosurgery, and Psychiatry. 2013 (PMID: 23457222).