SourceMed · Shelf #3756 in the ask interface

Robotic knee replacement lines the implant up better — alignment outliers roughly halved — but patients feel no difference: WOMAC difference -0.35 points in pooled randomised trials

Shelf #3756 · Bones & joints

SPLIT — robotic assistance improves alignment (outliers RR 0.43) across pooled RCTs, but patient-reported outcomes, motion and complications are the same as conventional surgery

Stamped: 2026-11-28.

Evidence published: 2023–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does robotic-assisted total knee arthroplasty improve alignment, pain or function versus conventional surgery?

Balance of the evidence

SPLIT — the x-ray improves, the patient does not (yet). A systematic review of 12 randomised trials, 2,200 patients (Ruangsomboon P et al., PMID: 36805771) found robotic-assisted total knee arthroplasty probably makes little to no difference to patient-reported outcomes (WOMAC mean difference -0.35, 95% CI -0.78 to 0.07) or range of motion (mean difference -0.73 degrees, CI -7.5 to 6.0), while likely reducing mechanical-alignment outliers (risk ratio 0.43, CI 0.27 to 0.67 — a 57% relative reduction) and deviation from neutral alignment (mean difference -0.94 degrees, CI -1.1 to -0.73). A second meta-analysis of 7 randomised trials, 1,942 knees (Alrajeb R et al., PMID: 38133653), found the same split: significantly better anatomical and mechanical restoration on imaging, with clinical and functional scores and complication rates statistically similar. Neither review could settle revision rates — the outcome better alignment is supposed to improve — because follow-up is too short. SPLIT: robotic assistance is a radiological improvement in search of a clinical one; on current randomised evidence patients should not expect to feel better, move better, or have fewer complications.

MeSH: Adult · Humans · Arthroplasty, Replacement, Knee/adverse effects · Robotic Surgical Procedures/adverse effects · Randomized Controlled Trials as Topic · Radiography · Knee Joint/diagnostic imaging/surgery

Cards (3)

Card 1 — Ruangsomboon 2023 (12 RCTs, 2,200 patients): WOMAC difference -0.35 (95% CI -0.78 to 0.07) — but alignment outliers RR 0.43 (0.27 to 0.67) favour the robot

Study: Systematic review and meta-analysis of randomised trials (Ruangsomboon 2023)

Population: 12 randomised controlled trials involving 2,200 adults undergoing primary total knee arthroplasty for osteoarthritis, robotic-assisted versus conventional jig-based technique.

Summary: Ruangsomboon 2023 (12 RCTs, 2,200 patients): WOMAC difference -0.35 (95% CI -0.78 to 0.07) — but alignment outliers RR 0.43 (0.27 to 0.67) favour the robot

Result: Patient-reported outcomes: WOMAC mean difference -0.35 (95% CI -0.78 to 0.07), interpreted as probably little to no effect. Range of motion: mean difference -0.73 degrees (CI -7.5 to 6.0). Mechanical alignment: outliers risk ratio 0.43 (CI 0.27 to 0.67) and deviation from neutral mean difference -0.94 degrees (CI -1.1 to -0.73), both favouring robotic surgery. No differences in revision rate or major adverse effects, with evidence on those outcomes rated insufficient.

Watch out: The trials span several robot generations and platforms, mostly with short follow-up; the revision question — the entire clinical rationale for better alignment — needs a decade, and these data do not have it. Industry involvement in the underlying trials is common in this literature.

Source: Ruangsomboon P et al. Clinical and radiological outcomes of robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. Acta orthopaedica. 2023. PMID: 36805771. MeSH: Adult · Humans · Arthroplasty, Replacement, Knee/adverse effects · Robotic Surgical Procedures/adverse effects · Randomized Controlled Trials as Topic · Radiography · Knee Joint/diagnostic imaging/surgery

Card 2 — Alrajeb 2024 (7 RCTs, 1,942 knees): anatomical and mechanical restoration significantly better with robotics; clinical scores, function and complications statistically similar

Study: Systematic review and meta-analysis of randomised trials (Alrajeb 2024)

Population: Seven randomised controlled trials, 1,942 knees (974 robotic, 968 conventional jig-based), comparing robotic versus conventional total knee replacement on radiological alignment, knee scores, WOMAC, range of motion and complications.

Summary: Alrajeb 2024 (7 RCTs, 1,942 knees): anatomical and mechanical restoration significantly better with robotics; clinical scores, function and complications statistically similar

Result: Robotic knees had significantly better post-operative anatomical restoration (odds ratio -0.82; 95% CI -1.027 to -0.58; p<0.00001) and mechanical restoration (odds ratio -0.95; 95% CI -1.49 to -0.41; p<0.0006). Range of motion and femoral prosthesis position favoured robotics without reaching significance (p=0.1 and p=0.07). Clinical and functional outcomes and complication rates were statistically similar between groups.

Watch out: Effect measures are reported as odds ratios for continuous alignment outcomes, which is hard to translate into millimetres a patient could care about; and this pool (search to June 2022) overlaps the other review's trials — two meta-analyses of largely the same RCTs are one evidence base, not two.

Source: Alrajeb R et al. Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. European journal of orthopaedic surgery & traumatology. 2024. PMID: 38133653. MeSH: Humans · Arthroplasty, Replacement, Knee/methods/adverse effects/instrumentation · Robotic Surgical Procedures/methods/adverse effects · Randomized Controlled Trials as Topic · Range of Motion, Articular · Treatment Outcome · Postoperative Complications/etiology/prevention & control · Knee Joint/surgery/physiopathology

Card 3 — Synthesis: the alignment win is consistent and the patient-level win is absent — the open question is revisions at 10 years, which no pooled trial can yet answer

Study: Synthesis

Population: Two meta-analyses (2023: 12 RCTs, 2,200 patients; 2024: 7 RCTs, 1,942 knees, substantially overlapping trial sets) of robotic-assisted versus conventional total knee arthroplasty.

Summary: Synthesis: the alignment win is consistent and the patient-level win is absent — the open question is revisions at 10 years, which no pooled trial can yet answer

Result: Alignment: outliers RR 0.43 (0.27 to 0.67), deviation from neutral -0.94 degrees — consistently better with robotics. Patient outcomes: WOMAC mean difference -0.35 (-0.78 to 0.07); range of motion, clinical scores, complications all statistically similar. Revisions: no difference shown, evidence insufficient. SPLIT: radiological benefit, clinical equivalence so far.

Watch out: Costs, operative time and the learning curve sit outside these records, as does every outcome beyond short-term follow-up. If long-term registries eventually show fewer revisions, this stamp should be revisited — on today's randomised evidence, feeling better is not among the robot's demonstrated effects.

Source: Synthesis of Ruangsomboon P et al. Acta orthopaedica. 2023 (PMID: 36805771); Alrajeb R et al. European journal of orthopaedic surgery & traumatology. 2024 (PMID: 38133653).