SourceMed · Shelf #3789 in the ask interface
Endometrial ablation beats the levonorgestrel intrauterine system on blood loss at 2 years (PBAC 14.2 versus 64.8) and surgical reintervention (10% versus 27%) — satisfaction and quality of life tie, and by 7 years hysterectomy rates converge
Shelf #3789 · Women’s health
POSSIBLE (benefit) — endometrial ablation controls blood loss better and needs less surgical reintervention than starting with a levonorgestrel intrauterine system in the MIRA trial, with equal satisfaction and quality of life
Stamped: 2026-11-28.
Evidence published: 2021–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
For heavy menstrual bleeding, how does endometrial ablation compare with the levonorgestrel intrauterine system on bleeding control, satisfaction and further surgery?
Balance of the evidence
POSSIBLE (benefit) — for ablation, on the mechanical outcomes; for the intrauterine system, on reversibility and avoiding a procedure, with satisfaction equal either way. In the MIRA randomised trial (Beelen P et al., PMID: 32795428), 270 women with heavy menstrual bleeding were allocated to a levonorgestrel intrauterine system or bipolar radiofrequency endometrial ablation: at 24 months the intrauterine system was not shown non-inferior on blood loss (Pictorial Blood Loss Assessment Chart scores 64.8 versus 14.2; difference 50.5 points, 95% CI 4.3-96.7; non-inferiority P=.87), and surgical reintervention was 27% versus 10% (relative risk 2.64, 95% CI 1.49-4.68), while satisfaction and quality of life did not differ significantly. At a mean 7.4 years (Huijs DPC et al., PMID: 38280433; 196 women), total reintervention was 40.0% versus 28.7% (RR 1.39, 95% CI 0.92-2.10), surgical reintervention remained higher after starting with the system (35.3% versus 19.1%; RR 1.84, 95% CI 1.11-3.10), but hysterectomy rates were similar (11.8% versus 18.1%; RR 0.65, 95% CI 0.32-1.34) and median bleeding scores were 0.0 in the follow-up sample. POSSIBLE (benefit) for ablation on bleeding control and durability — Tier C, because one trial and its own follow-up carry the comparison.
MeSH: Adult · Contraceptive Agents, Hormonal/administration & dosage · Endometrial Ablation Techniques/methods · Female · Humans · Intrauterine Devices, Medicated · Levonorgestrel/administration & dosage · Menorrhagia/physiopathology/therapy · Middle Aged · Netherlands · Patient Satisfaction · Quality of Life · Retreatment · Sexual Health · Treatment Outcome
Cards (3)
Card 1 — Beelen 2021 (MIRA): blood loss at 24 months PBAC 64.8 intrauterine system versus 14.2 ablation — non-inferiority not shown (P=.87); surgical reintervention 27% versus 10% (RR 2.64)
Study: Randomised non-inferiority trial (Beelen 2021, MIRA)
Population: 270 women aged 34 or older with heavy menstrual bleeding, no pregnancy wish and no intracavitary pathology, in 26 Dutch hospitals and a general-practice network, randomised to a 52-mg levonorgestrel intrauterine system (n=132; the record names the product as Mirena) or bipolar radiofrequency endometrial ablation (n=138; device named as NovaSure); primary outcome blood loss (PBAC score) at 24 months. Registry ID: NL2842 (Netherlands Trial Register).
Summary: Beelen 2021 (MIRA): blood loss at 24 months PBAC 64.8 intrauterine system versus 14.2 ablation — non-inferiority not shown (P=.87); surgical reintervention 27% versus 10% (RR 2.64)
Result: At 24 months, mean PBAC scores were 64.8 in the intrauterine-system group and 14.2 in the ablation group (difference 50.5 points, 95% CI 4.3-96.7); non-inferiority of the system was not demonstrated (P=.87 against a 25-point margin). Surgical reintervention occurred in 34 women (27%) starting with the system versus 14 women (10%) after ablation (relative risk 2.64, 95% CI 1.49-4.68). There was no significant difference in patient satisfaction or quality of life. Both strategies produced a large decrease from baseline PBAC scores of about 616-630.
Watch out: A strategy trial: women randomised to the system could cross to ablation and surgery, which is exactly what the reintervention endpoint counts — it measures the durability of starting with the coil, not the coil's effect while retained. Ablation ends fertility, so the trial's no-pregnancy-wish entry criterion is part of the answer.
Source: Beelen P et al. Levonorgestrel-releasing intrauterine system versus endometrial ablation for heavy menstrual bleeding. American journal of obstetrics and gynecology. 2021. PMID: 32795428. Registry ID: NL2842. MeSH: Adult · Contraceptive Agents, Hormonal/administration & dosage · Endometrial Ablation Techniques/methods · Female · Humans · Intrauterine Devices, Medicated · Levonorgestrel/administration & dosage · Menorrhagia/physiopathology/therapy · Middle Aged · Netherlands · Patient Satisfaction · Quality of Life · Retreatment · Sexual Health · Treatment Outcome
Card 2 — Huijs 2024 (MIRA long-term, mean 7.4 years): surgical reintervention still higher after the system (35.3% versus 19.1%; RR 1.84) — hysterectomy similar (11.8% versus 18.1%)
Study: Long-term follow-up of a randomised trial (Huijs 2024, MIRA)
Population: 196 of the 270 MIRA participants (94 intrauterine system, 102 ablation) completing questionnaires at a mean follow-up of 7.4 years (range 6-9 years); primary outcome cumulative reintervention after the allocated treatment strategy.
Summary: Huijs 2024 (MIRA long-term, mean 7.4 years): surgical reintervention still higher after the system (35.3% versus 19.1%; RR 1.84) — hysterectomy similar (11.8% versus 18.1%)
Result: Cumulative reintervention (medical and surgical) was 40.0% (34/85) after starting with the intrauterine system versus 28.7% (27/94) after ablation (relative risk 1.39, 95% CI 0.92-2.10). Surgical reintervention alone was significantly higher after the system (35.3% versus 19.1%; RR 1.84, 95% CI 1.11-3.10). Hysterectomy rates were similar (11.8% versus 18.1%; RR 0.65, 95% CI 0.32-1.34). Most reinterventions occurred in the first 24 months; median PBAC score in the follow-up sample was 0.0, with no clinically relevant differences in quality of life, sexual function or satisfaction.
Watch out: A 73% questionnaire follow-up of one trial, with denominators shifting between outcomes (85-102 per group) — the long-term picture is consistent with the two-year result but rests on the same single randomised cohort.
Source: Huijs DPC et al. A 52-mg levonorgestrel-releasing intrauterine system vs bipolar radiofrequency nonresectoscopic endometrial ablation in women with heavy menstrual bleeding: long-term follow-up of a multicenter randomized controlled trial. American journal of obstetrics and gynecology. 2024. PMID: 38280433. MeSH: Humans · Female · Levonorgestrel/administration & dosage/therapeutic use · Menorrhagia/surgery · Intrauterine Devices, Medicated · Endometrial Ablation Techniques/methods · Adult · Follow-Up Studies · Middle Aged · Patient Satisfaction · Quality of Life · Reoperation/statistics & numerical data · Treatment Outcome
Card 3 — Synthesis: start with ablation for the driest, most durable result; start with the coil to keep options open — a quarter to a third will move on to surgery either way
Study: Synthesis
Population: The MIRA randomised strategy trial (270 women) at 24 months and at a mean of 7.4 years (196 respondents).
Summary: Synthesis: start with ablation for the driest, most durable result; start with the coil to keep options open — a quarter to a third will move on to surgery either way
Result: PBAC at 24 months: 64.8 versus 14.2. Surgical reintervention: 27% versus 10% at two years; 35.3% versus 19.1% long-term. Hysterectomy long-term: 11.8% versus 18.1% (NS). Satisfaction and quality of life: no significant differences at either time point. POSSIBLE (benefit) for ablation, Tier C: single-trial base.
Watch out: Women who may want pregnancy, or who prefer to avoid theatre entirely, are outside this comparison's logic — for them the intrauterine system is not the 'losing' arm but the only applicable one.
Source: Synthesis of Beelen P et al. American journal of obstetrics and gynecology. 2021 (PMID: 32795428); Huijs DPC et al. American journal of obstetrics and gynecology. 2024 (PMID: 38280433).