SourceMed · Shelf #4022 in the ask interface

PreserFlo MicroShunt is NOT trabeculectomy's equal on pressure: success 53.9% versus 72.7% and pressure 14.3 versus 11.1 mmHg at one year — its case is fewer interventions (40.8% versus 67.4%) and less hypotony

Shelf #4022 · Eyes, skin, nose & allergy

SPLIT — MicroShunt is inferior on pressure and success (53.9% vs 72.7%; 14.3 vs 11.1 mmHg) but needs fewer postoperative interventions (40.8% vs 67.4%) and causes less transient hypotony (28.9% vs 49.6%); single RCT plus meta-analysis, hence Tier C

Stamped: 2026-11-28.

Evidence published: 2021–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In open-angle glaucoma, is the PreserFlo MicroShunt non-inferior to trabeculectomy for lowering intraocular pressure, with fewer complications?

Balance of the evidence

SPLIT — the non-inferiority claim fails on efficacy and succeeds only on parts of safety. In the randomised trial (Baker ND et al., PMID: 34051211; 527 patients with primary open-angle glaucoma), one-year surgical success (≥20% pressure reduction without more medication) was 53.9% with the MicroShunt versus 72.7% with trabeculectomy (P<0.01), and mean pressure fell to 14.3 mmHg (−29.1%) versus 11.1 mmHg (−45.4%). Against that, postoperative interventions were fewer with the MicroShunt (40.8% versus 67.4%) and transient hypotony less common (28.9% versus 49.6%), with vision-threatening complications uncommon in both arms (~1.0% MicroShunt). The 2025 meta-analysis (Governatori L et al., PMID: 39394492; 10 studies, 1,833 eyes) agrees: trabeculectomy achieved lower pressure (mean difference ~1.6–2.5 mmHg in trabeculectomy's favour), while the MicroShunt carried lower hypotony-maculopathy risk (OR 0.30) but higher reintervention rates in several subgroups. SPLIT: choose trabeculectomy for maximum pressure lowering; the MicroShunt trades pressure for a quieter postoperative course.

MeSH: Adult · Aged · Aged, 80 and over · Alkylating Agents/administration & dosage · Antihypertensive Agents/administration & dosage · Female · Follow-Up Studies · Glaucoma Drainage Implants · Glaucoma, Open-Angle/drug therapy/physiopathology/surgery · Humans · Intraocular Pressure/physiology · Male · Middle Aged · Mitomycin/administration & dosage · Prospective Studies · Prosthesis Implantation · Single-Blind Method · Tonometry, Ocular · Trabeculectomy · Treatment Outcome · Visual Acuity/physiology · Visual Fields/physiology

Cards (3)

Card 1 — Panarelli/Baker randomised trial: success 53.9% MicroShunt vs 72.7% trabeculectomy; pressure 14.3 vs 11.1 mmHg; interventions 40.8% vs 67.4%; hypotony 28.9% vs 49.6%

Study: Randomised multicentre non-inferiority study, 1-year results (Baker 2021)

Population: 527 patients aged 40–85 with primary open-angle glaucoma, pressure 15–40 mmHg inadequately controlled on maximum tolerated therapy, randomised 3:1 to stand-alone ab-externo MicroShunt implantation (395) or trabeculectomy (132), both with mitomycin C. Mean visual-field mean deviation −12.34 dB. NCT01881425.

Summary: Panarelli/Baker randomised trial: success 53.9% MicroShunt vs 72.7% trabeculectomy; pressure 14.3 vs 11.1 mmHg; interventions 40.8% vs 67.4%; hypotony 28.9% vs 49.6%

Result: Probability of surgical success at year 1 (≥20% reduction in mean diurnal pressure without increased medication count) was 53.9% (MicroShunt) versus 72.7% (trabeculectomy) (P<0.01) — non-inferiority not shown. Mean pressure fell from 21.1 mmHg in both groups to 14.3 ± 4.3 (−29.1%) versus 11.1 ± 4.3 mmHg (−45.4%); medications fell to 0.6 versus 0.3 (from ~3.1). Postoperative interventions including laser suture lysis: 40.8% versus 67.4% (P<0.01). Transient hypotony: 28.9% versus 49.6% (P<0.01). Vision-threatening complications were uncommon (1.0% in the MicroShunt arm as reported).

Watch out: One-year results of a 2-year study, with a 3:1 randomisation that leaves the trabeculectomy arm comparatively small (n=132). 'Success' is a composite that penalises added drops — a patient at 15 mmHg on one drop counts as failure here, which flatters neither arm's real-world usefulness equally.

Source: Baker ND et al. Ab-Externo MicroShunt versus Trabeculectomy in Primary Open-Angle Glaucoma: One-Year Results from a 2-Year Randomized, Multicenter Study. Ophthalmology. 2021. PMID: 34051211. Registry ID: NCT01881425. MeSH: Adult · Aged · Aged, 80 and over · Alkylating Agents/administration & dosage · Antihypertensive Agents/administration & dosage · Female · Follow-Up Studies · Glaucoma Drainage Implants · Glaucoma, Open-Angle/drug therapy/physiopathology/surgery · Humans · Intraocular Pressure/physiology · Male · Middle Aged · Mitomycin/administration & dosage · Prospective Studies · Prosthesis Implantation · Single-Blind Method · Tonometry, Ocular · Trabeculectomy · Treatment Outcome · Visual Acuity/physiology · Visual Fields/physiology

Card 2 — Meta-analysis 2025 (10 studies, 1,833 eyes): trabeculectomy lowers pressure more (MD ~1.6–2.5 mmHg); MicroShunt has less hypotony maculopathy (OR 0.30) but more reintervention in key subgroups

Study: Systematic review and meta-analysis (Governatori 2025)

Population: 10 randomised and non-randomised studies (1,833 eyes; 57.4% MicroShunt) in moderate-to-advanced glaucoma (mean deviation worse than −6 dB), comparing PreserFlo MicroShunt with trabeculectomy on success, pressure, complications and reintervention, searched to January 2024.

Summary: Meta-analysis 2025 (10 studies, 1,833 eyes): trabeculectomy lowers pressure more (MD ~1.6–2.5 mmHg); MicroShunt has less hypotony maculopathy (OR 0.30) but more reintervention in key subgroups

Result: Qualified and complete success rates did not differ significantly overall. Trabeculectomy achieved better pressure outcomes (mean difference 1.59 mmHg, p=0.0004, and greater pressure reduction, MD −2.52 mmHg, p=0.0003). The MicroShunt showed less visual-field progression in the pooled estimate (MD −1.21, p=0.03) and lower hypotony-maculopathy risk (OR 0.30, p=0.03), but a higher reintervention rate in patients without prior glaucoma surgery (OR 1.74, p=0.02) and in primary open-angle glaucoma (OR 1.84, p=0.04).

Watch out: Most included studies are non-randomised, so the pooled success-rate equivalence is weaker evidence than the single randomised trial's clear efficacy gap; the visual-field-progression signal (p=0.03 across many outcomes) should be read as hypothesis-generating.

Source: Governatori L et al. PreserFlo MicroShunt versus trabeculectomy: an updated meta-analysis and systematic review. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2025. PMID: 39394492. MeSH: Humans · Trabeculectomy/methods · Intraocular Pressure/physiology · Visual Fields/physiology · Glaucoma/surgery/physiopathology · Microsurgery/methods · Visual Acuity

Card 3 — Synthesis: on pressure, trabeculectomy wins in the trial and the meta-analysis; on postoperative burden, the MicroShunt wins — the question's 'non-inferior with fewer complications' is half right

Study: Synthesis

Population: One randomised trial (527 patients, 1 year) and one meta-analysis (10 studies, 1,833 eyes, mostly non-randomised).

Summary: Synthesis: on pressure, trabeculectomy wins in the trial and the meta-analysis; on postoperative burden, the MicroShunt wins — the question's 'non-inferior with fewer complications' is half right

Result: Success 53.9% vs 72.7%; final pressure 14.3 vs 11.1 mmHg; interventions 40.8% vs 67.4%; transient hypotony 28.9% vs 49.6%. SPLIT as stamped, Tier C: the randomised base is a single trial.

Watch out: Target pressure decides the case: eyes needing low-teens or single-digit pressures are trabeculectomy territory on this evidence; eyes where hypotony risk dominates may rationally accept the MicroShunt's higher final pressure.

Source: Synthesis of Baker ND et al. Ophthalmology. 2021 (PMID: 34051211); Governatori L et al. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2025 (PMID: 39394492).