Screening asymptomatic diabetes for silent coronary disease: neither stress imaging (DIAD) nor CT angiography (FACTOR-64) reduced cardiac events
Shelf #4167 · Diabetes, glucose & metabolism
LIKELY (the treatment made no difference) — two randomised trials found no event reduction from screening asymptomatic diabetes for coronary disease, by stress perfusion imaging (hazard ratio 0.88) or by CT angiography (hazard ratio 0.80, with the ischaemic composite numerically worse)
Stamped: 2026-11-28.
Evidence published: 2009–2014.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In people with diabetes who have no symptoms of coronary artery disease, does routine screening for silent coronary disease — by stress myocardial perfusion imaging or by CT coronary angiography — reduce cardiac death, myocardial infarction and related events?
Balance of the evidence
LIKELY (the treatment made no difference) — two randomised screening trials, two imaging technologies, one answer. In DIAD (1,123 asymptomatic patients with type 2 diabetes), cardiac death or nonfatal myocardial infarction over 4.8 years occurred in 2.7% of the screened group and 3.0% of the unscreened group (hazard ratio 0.88; 95% CI 0.44 to 1.88); overall event rates were low (2.9% cumulative), and even moderate-to-large perfusion defects had a positive predictive value of only 12%. In FACTOR-64 (900 patients with type 1 or type 2 diabetes), CT-angiography screening gave a primary outcome (death, nonfatal infarction, or unstable-angina hospitalisation) in 6.2% versus 7.6% on standard care (hazard ratio 0.80; 95% CI 0.49 to 1.32), and the ischaemic composite was numerically worse with screening (4.4% versus 3.8%; hazard ratio 1.15). Finding silent disease did not translate into preventing events, largely because background preventive therapy rose equally in both arms. LIKELY (the treatment made no difference): routine imaging screening for coronary disease in asymptomatic diabetes does not reduce cardiac events.
MeSH: Adenosine · Coronary Artery Disease/*diagnostic imaging/*etiology/mortality · Diabetes Mellitus, Type 2/*complications · Diabetic Angiopathies/*diagnostic imaging/etiology/mortality · Exercise Test · Female · Humans · Male · Middle Aged · Myocardial Infarction/epidemiology/etiology · *Myocardial Perfusion Imaging · Radiopharmaceuticals · Technetium Tc 99m Sestamibi · Vasodilator Agents
Cards (3)
Card 1 — DIAD (Young 2009): cardiac death or nonfatal infarction in 2.7% of the screened group versus 3.0% unscreened (hazard ratio 0.88; 95% CI 0.44 to 1.88) over 4.8 years
Study: Randomised controlled trial (DIAD — Detection of Ischemia in Asymptomatic Diabetics)
Population: 1,123 participants with type 2 diabetes and no symptoms of coronary artery disease, recruited from diabetes clinics and practices, randomised to screening with adenosine-stress radionuclide myocardial perfusion imaging or to no screening, and followed for a mean of 4.8 years; the primary outcome was cardiac death or nonfatal myocardial infarction.
Summary: DIAD (Young 2009): cardiac death or nonfatal infarction in 2.7% of the screened group versus 3.0% unscreened (hazard ratio 0.88; 95% CI 0.44 to 1.88) over 4.8 years
Result: The cumulative cardiac event rate was 2.9% over 4.8 years (0.6% per year). Seven nonfatal infarctions and 8 cardiac deaths (2.7%) occurred in the screened group and 10 nonfatal infarctions and 7 cardiac deaths (3.0%) in the unscreened group (hazard ratio 0.88; 95% CI 0.44 to 1.88; P = .73). Among screened patients, moderate or large perfusion defects predicted events (2.4% per year versus 0.4% per year with normal or small defects; hazard ratio 6.3) but the positive predictive value of a moderate or large defect was only 12%. Coronary revascularisation was infrequent in both groups (5.5% screened versus 7.8% unscreened), and primary medical prevention intensified significantly and equally in both groups during the study.
Watch out: Event rates were far lower than expected when the trial was designed, limiting power for small effects; the trial tests a screening strategy in type 2 diabetes, not the diagnostic use of imaging in symptomatic patients.
Source: Young et al. Cardiac outcomes after screening for asymptomatic coronary artery disease in patients with type 2 diabetes: the DIAD study: a randomized controlled trial. JAMA. 2009. PMID: 19366774. Registry ID: NCT00769275. MeSH: Adenosine · Coronary Artery Disease/*diagnostic imaging/*etiology/mortality · Diabetes Mellitus, Type 2/*complications · Diabetic Angiopathies/*diagnostic imaging/etiology/mortality · Exercise Test · Female · Humans · Male · Middle Aged · Myocardial Infarction/epidemiology/etiology · *Myocardial Perfusion Imaging · Radiopharmaceuticals · Technetium Tc 99m Sestamibi · Vasodilator Agents
Card 2 — FACTOR-64 (Muhlestein 2014): primary outcome in 6.2% with CT-angiography screening versus 7.6% on standard care (hazard ratio 0.80; 95% CI 0.49 to 1.32; P = .38)
Study: Randomised clinical trial (FACTOR-64)
Population: 900 patients with type 1 or type 2 diabetes and no symptoms of coronary artery disease, randomised to screening with coronary CT angiography (452 patients), with guideline-directed care recommended from the findings, or to standard national-guideline-based care (448); mean follow-up 4.0 years.
Summary: FACTOR-64 (Muhlestein 2014): primary outcome in 6.2% with CT-angiography screening versus 7.6% on standard care (hazard ratio 0.80; 95% CI 0.49 to 1.32; P = .38)
Result: The primary outcome (all-cause mortality, nonfatal myocardial infarction, or unstable angina requiring hospitalisation) occurred in 6.2% (28 events) in the CT-angiography group and 7.6% (34 events) in the control group (hazard ratio 0.80; 95% CI 0.49 to 1.32; P = .38). The secondary ischaemic composite (coronary death, nonfatal infarction, or unstable angina) occurred in 4.4% (20 events) versus 3.8% (17 events) (hazard ratio 1.15; 95% CI 0.60 to 2.19; P = .68). The authors concluded the findings do not support CT-angiography screening in this population.
Watch out: A single health-system trial with modest event counts; screening triggered more downstream testing and therapy by design, which is part of the strategy being judged — and it still did not reduce events.
Source: Muhlestein et al. Effect of screening for coronary artery disease using CT angiography on mortality and cardiac events in high-risk patients with diabetes: the FACTOR-64 randomized clinical trial. JAMA. 2014. PMID: 25402757. Registry ID: NCT00488033. MeSH: Aged · Angina, Unstable/prevention & control · Coronary Angiography/*methods · Coronary Artery Disease/complications/*diagnostic imaging/mortality · Diabetes Mellitus, Type 1/*complications · Diabetes Mellitus, Type 2/*complications · Female · Hospitalization · Humans · Male · Middle Aged · Myocardial Infarction/prevention & control · Risk · Tomography, X-Ray Computed/*methods
Card 3 — Synthesis: in asymptomatic diabetes, looking harder for coronary disease did not prevent it from declaring itself
Study: Synthesis
Population: People with diabetes and no cardiac symptoms, in whom routine coronary screening is proposed.
Summary: Synthesis: in asymptomatic diabetes, looking harder for coronary disease did not prevent it from declaring itself
Result: DIAD (hazard ratio 0.88 for cardiac death or infarction) and FACTOR-64 (hazard ratio 0.80 for its primary composite, 1.15 for the ischaemic composite) agree across imaging modalities: screening finds risk markers but does not reduce events, because effective preventive therapy is — and should be — given on the basis of diabetes itself.
Watch out: Coronary artery calcium scoring as a risk-refinement tool, and imaging for symptoms or pre-operative assessment, are different questions not graded by these trials.
Source: Synthesis of DIAD (PMID: 19366774) and FACTOR-64 (PMID: 25402757).