SourceMed · Shelf #4169 in the ask interface
Transcatheter edge-to-edge repair versus mitral surgery for secondary mitral regurgitation (MATTERHORN): noninferior on efficacy at 1 year, with far fewer major adverse events (14.9% versus 54.8%)
Shelf #4169 · Heart, vessels, blood pressure & clotting
POSSIBLE (benefit) — in the single MATTERHORN randomised trial, transcatheter edge-to-edge repair was noninferior to mitral surgery for the 1-year efficacy composite (16.7% versus 22.5%) and caused far fewer 30-day major adverse events (14.9% versus 54.8%)
Stamped: 2026-11-28.
Evidence published: 2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with heart failure and secondary (functional) mitral regurgitation who remain symptomatic on guideline-directed medical therapy, is transcatheter edge-to-edge repair noninferior to mitral-valve surgery for death, heart-failure hospitalisation, reintervention, assist-device implantation or stroke at 1 year — and how do early major adverse events compare?
Balance of the evidence
POSSIBLE (benefit) — a single, small noninferiority trial in which the catheter strategy matched surgery on outcomes and clearly beat it on early harm. In MATTERHORN (210 patients with heart failure and secondary mitral regurgitation, symptomatic despite guideline-directed therapy), the primary efficacy composite (death, heart-failure hospitalisation, mitral reintervention, assist-device implantation, or stroke within 1 year) occurred in 16.7% after transcatheter edge-to-edge repair versus 22.5% after surgery (estimated difference -6 percentage points; 95% CI -17 to 6; P < 0.001 for noninferiority). The primary safety endpoint — major adverse events within 30 days — occurred in 14.9% after repair versus 54.8% after surgery (difference -40 percentage points; 95% CI -51 to -27; P < 0.001). Because the claim rests on one trial of 210 patients with a composite that includes mortality, this shelf is POSSIBLE. POSSIBLE (benefit): for suitable patients with secondary mitral regurgitation, edge-to-edge repair probably achieves surgical-level 1-year outcomes with a much smaller early adverse-event burden.
MeSH: Aged · Female · Humans · Male · Middle Aged · *Cardiac Catheterization/adverse effects · *Heart Failure/complications/mortality/surgery · *Heart Valve Prosthesis Implantation/adverse effects/methods · Hospitalization · Kaplan-Meier Estimate · *Mitral Valve/surgery · *Mitral Valve Insufficiency/etiology/mortality/surgery · Postoperative Complications/epidemiology/etiology · Stroke/epidemiology/etiology/prevention & control · Heart-Assist Devices/statistics & numerical data
Cards (2)
Card 1 — MATTERHORN (Baldus 2024): efficacy composite in 16 of 96 patients (16.7%) after edge-to-edge repair versus 20 of 89 (22.5%) after surgery (P < 0.001 for noninferiority); 30-day major adverse events 14.9% versus 54.8%
Study: Randomised noninferiority trial (MATTERHORN)
Population: 210 patients with heart failure and secondary mitral regurgitation who remained symptomatic despite guideline-directed medical therapy, at German centres, randomised 1:1 to transcatheter edge-to-edge repair or surgical mitral-valve repair or replacement; mean age 70.5 years, 39.9% women, mean ejection fraction 43.0%.
Summary: MATTERHORN (Baldus 2024): efficacy composite in 16 of 96 patients (16.7%) after edge-to-edge repair versus 20 of 89 (22.5%) after surgery (P < 0.001 for noninferiority); 30-day major adverse events 14.9% versus 54.8%
Result: Within 1 year, at least one component of the primary efficacy endpoint (death, hospitalisation for heart failure, mitral-valve reintervention, implantation of an assist device, or stroke) occurred in 16 of 96 patients with available data (16.7%) in the repair group and 20 of 89 (22.5%) in the surgery group (estimated mean difference -6 percentage points; 95% CI -17 to 6; P < 0.001 for noninferiority). A primary safety endpoint event (major adverse events within 30 days) occurred in 15 of 101 patients (14.9%) after repair versus 51 of 93 (54.8%) after surgery (estimated mean difference -40 percentage points; 95% CI -51 to -27; P < 0.001).
Watch out: Small for a noninferiority claim on a mortality-containing composite, with incomplete outcome data (96 and 89 of about 105 per arm for the efficacy endpoint) and 1-year follow-up only; surgical candidacy and valve anatomy determine who these results apply to.
Source: Baldus et al. Transcatheter Repair versus Mitral-Valve Surgery for Secondary Mitral Regurgitation. The New England journal of medicine. 2024. PMID: 39216093. Registry ID: NCT02371512. MeSH: Aged · Female · Humans · Male · Middle Aged · *Cardiac Catheterization/adverse effects · *Heart Failure/complications/mortality/surgery · *Heart Valve Prosthesis Implantation/adverse effects/methods · Hospitalization · Kaplan-Meier Estimate · *Mitral Valve/surgery · *Mitral Valve Insufficiency/etiology/mortality/surgery · Postoperative Complications/epidemiology/etiology · Stroke/epidemiology/etiology/prevention & control · Heart-Assist Devices/statistics & numerical data
Card 2 — Synthesis: against surgery — the comparison that was missing — catheter repair holds its own at 1 year
Study: Synthesis
Population: Patients with symptomatic secondary mitral regurgitation on medical therapy who are candidates for either transcatheter repair or surgery.
Summary: Synthesis: against surgery — the comparison that was missing — catheter repair holds its own at 1 year
Result: MATTERHORN is the first randomised head-to-head against surgery: efficacy was noninferior (16.7% versus 22.5% for the composite) and early major adverse events were roughly a quarter as frequent (14.9% versus 54.8%). Combined with the established trials of repair versus medical therapy alone (carded separately), the catheter approach now has randomised support on both flanks — but this shelf's grade stays POSSIBLE on a single 210-patient trial.
Watch out: Long-term durability of edge-to-edge repair versus surgery beyond 1 year, and outcomes in patients at low surgical risk, remain untested by this trial.
Source: Synthesis of MATTERHORN (PMID: 39216093).