SourceMed · Shelf #4233 in the ask interface

Endocuff Vision at colonoscopy: adenoma detection rose from 36.2% to 40.9% in ADENOMA, driven by screening patients (61.7% vs 50.9%) — but the same device changed nothing at flexible sigmoidoscopy (13.3% vs 12.2%)

Shelf #4233 · Liver & gut

SPLIT — Endocuff Vision raised adenoma detection at colonoscopy (40.9% vs 36.2%, concentrated in screening patients) but not at flexible sigmoidoscopy screening (13.3% vs 12.2%)

Stamped: 2026-11-28.

Evidence published: 2019–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does attaching the Endocuff Vision mucosal-exposure device to the endoscope increase adenoma detection — at colonoscopy, and at flexible sigmoidoscopy screening?

Balance of the evidence

SPLIT — the device helped where baseline detection and lesion yield were high, and did nothing where they were low. In the ADENOMA colonoscopy trial (Ngu WS et al., PMID: 29363535), adenoma detection was 40.9% with Endocuff Vision versus 36.2% with standard colonoscopy (P=0.02), driven by a 10.8-point gain in faecal-occult-blood-positive screening patients (61.7% vs 50.9%, P<0.001), with more cancers found (4.1% vs 2.3%, P=0.02). In the B-ADENOMA flexible sigmoidoscopy trial (Rees CJ et al., PMID: 32245908), detection was 13.3% with the device versus 12.2% without (p=0.353), with no differences in polyp yield, procedure time or experience. SPLIT: Endocuff Vision is a detection aid with a real but context-dependent effect — worthwhile in screening colonoscopy on this record, unproven at one-off sigmoidoscopy — and detection remains a surrogate for cancer prevention in both trials.

MeSH: Adenoma/diagnostic imaging/pathology · Colonoscopes · Colonoscopy/methods · Colorectal Neoplasms/diagnostic imaging/pathology · Diagnosis, Differential · England · Equipment Design · Female · Humans · Male · Mass Screening/methods · Middle Aged · Quality Improvement

Cards (3)

Card 1 — ADENOMA (Ngu 2019): adenoma detection 40.9% vs 36.2% overall (P=0.02); 61.7% vs 50.9% in FOBt-positive screening patients; cancers 4.1% vs 2.3%

Study: Randomised controlled trial (Ngu 2019, ADENOMA)

Population: 1,772 patients (57% male, mean age 62 years; 45% recruited through the Bowel Cancer Screening Programme) referred for colonoscopy for symptoms, surveillance or a positive faecal occult blood test at seven English hospitals, randomised to Endocuff Vision-assisted or standard colonoscopy.

Summary: ADENOMA (Ngu 2019): adenoma detection 40.9% vs 36.2% overall (P=0.02); 61.7% vs 50.9% in FOBt-positive screening patients; cancers 4.1% vs 2.3%

Result: Adenoma detection rate: 40.9% with Endocuff Vision versus 36.2% standard (P=0.02). The increase was driven by FOBt-positive screening patients: 61.7% versus 50.9% (a 10.8% increase, P<0.001). Endocuff patients also had higher mean adenomas per procedure and higher detection of sessile serrated polyps, left-sided, diminutive and small adenomas, and cancers (4.1% vs 2.3%, P=0.02). The device was removed in 4.1% of cases; median intubation was a minute quicker, with no difference in caecal intubation or withdrawal time and no significant device adverse events.

Watch out: The headline gain is a subgroup-driven result in a high-prevalence screening population; in symptomatic and surveillance patients the separation was smaller, and adenoma detection — especially of diminutive lesions — is a surrogate whose conversion into fewer interval cancers is inferred, not measured, here.

Source: Ngu WS et al. Improved adenoma detection with Endocuff Vision: the ADENOMA randomised controlled trial. Gut. 2019. PMID: 29363535. Registry ID: NCT02552017; ISRCTN11821044. MeSH: Adenoma/diagnostic imaging/pathology · Colonoscopes · Colonoscopy/methods · Colorectal Neoplasms/diagnostic imaging/pathology · Diagnosis, Differential · England · Equipment Design · Female · Humans · Male · Mass Screening/methods · Middle Aged · Quality Improvement

Card 2 — B-ADENOMA (Rees 2020): adenoma detection 13.3% with Endocuff vs 12.2% standard at flexible sigmoidoscopy (p=0.353) — no gain on any measure

Study: Randomised controlled trial (Rees 2020, B-ADENOMA)

Population: 3,222 participants (53% male) in the English BowelScope one-off flexible sigmoidoscopy screening programme at age 55, randomised at 16 centres to Endocuff Vision-assisted (n=1,610) or standard (n=1,612) sigmoidoscopy.

Summary: B-ADENOMA (Rees 2020): adenoma detection 13.3% with Endocuff vs 12.2% standard at flexible sigmoidoscopy (p=0.353) — no gain on any measure

Result: Adenoma detection rate: 13.3% with Endocuff Vision versus 12.2% standard (p=0.353). No statistically significant differences were found in polyp detection rate, mean adenomas per procedure, polyp characteristics or location, participant experience, complications or procedural characteristics. Adenoma detection in the standard arm was itself 3.1% higher than the national BowelScope rate.

Watch out: A shorter examination of the left colon in an average-risk screening population with a low baseline detection rate is a different test from full colonoscopy in FOBt-positive patients; the null here bounds the device's value in low-yield settings rather than contradicting the colonoscopy result.

Source: Rees CJ et al. BowelScope: Accuracy of Detection Using Endocuff Optimisation of Mucosal Abnormalities (the B-ADENOMA Study): a multicentre, randomised controlled flexible sigmoidoscopy trial. Gut. 2020. PMID: 32245908. Registry ID: NCT03072472; ISRCTN30005319. MeSH: Adenoma/diagnosis · Aged · Colonic Neoplasms/diagnosis · Colonic Polyps/diagnosis · England · Female · Humans · Intestinal Mucosa/pathology · Male · Middle Aged · Reproducibility of Results · Sigmoidoscopy/instrumentation

Card 3 — Synthesis: same device, two procedures — a real colonoscopy gain concentrated in screening, a sigmoidoscopy null

Study: Synthesis

Population: Two English multicentre randomised trials of Endocuff Vision: 1,772 colonoscopy patients (ADENOMA) and 3,222 flexible sigmoidoscopy screening participants (B-ADENOMA).

Summary: Synthesis: same device, two procedures — a real colonoscopy gain concentrated in screening, a sigmoidoscopy null

Result: Colonoscopy adenoma detection 40.9% versus 36.2% (screening subgroup 61.7% versus 50.9%; cancers 4.1% versus 2.3%). Sigmoidoscopy detection 13.3% versus 12.2% (not significant). SPLIT, as in the balance above.

Watch out: Neither trial measures interval cancers or mortality; both were conducted within one national screening system with trained operators, and device removal (4.1% in ADENOMA) and anal-intubation discomfort temper routine use. Tier C is not set: two large randomised trials, read together, carry the split claim.

Source: Synthesis of Ngu WS et al. Gut. 2019 (PMID: 29363535); Rees CJ et al. Gut. 2020 (PMID: 32245908).