SourceMed · Shelf #428 in the ask interface

REBOA for uncontrolled bleeding: UK-REBOA — the balloon may increase mortality

Shelf #428 · Emergency & first hours

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In trauma patients with exsanguinating hemorrhage, does adding REBOA to standard emergency department care reduce mortality?

Balance of the evidence

One randomized trial exists, and it points the wrong way: in UK-REBOA, 90-day mortality was 54% with a REBOA strategy vs 42% with standard care alone (OR 1.58 [95% credible interval 0.72–3.52]; 86.9% posterior probability of increased odds of death), with every earlier mortality endpoint leaning the same direction and more deaths from bleeding in the REBOA group. The trial is small and its interval includes no effect — a harm signal, stated as a signal. REBOA spread through trauma systems on registry data and mechanism; the first randomized test found no benefit to weigh against the signal. Tier C — mortality/harm claim.

MeSH: Aorta · Balloon Occlusion · Emergency Service, Hospital · Exsanguination · Female · Hemorrhage · Humans · Injury Severity Score · Male · Resuscitation · United Kingdom

Cards (1)

Card 1 — UK-REBOA (Jansen 2023, JAMA): 90-day mortality 54% with REBOA vs 42% without — the only randomized test leans toward harm

Study: Pragmatic, Bayesian, randomized clinical trial (UK-REBOA), JAMA 2023. Registry ID from the record’s own registration line: ISRCTN16184981.

Population: 90 patients aged 16 years or older with exsanguinating hemorrhage, enrolled October 2017 to March 2022 and followed for 90 days; 89 were included in the primary analysis. Median age 41 years (IQR 31–59); 69% male; median Injury Severity Score 41 (IQR 29–50).

Summary: 90 trauma patients with exsanguinating hemorrhage at 16 UK major trauma centers, randomized to a REBOA-plus-standard-care strategy (n=46) or standard care alone (n=44). All-cause mortality at 90 days: 25 of 46 (54%) vs 18 of 43 (42%) — OR 1.58 [95% credible interval 0.72–3.52], relative ; the posterior probability that REBOA increased the odds of death was 86.9% . Every secondary mortality time point (3 hours, 6 hours, 24 hours, in-hospital, 6 months) leaned the same way, more strongly at earlier times. More of the REBOA group’s deaths were due to bleeding: 8 of 25 deaths (32%) vs 3 of 18 (17%) .

Result: At 90 days, 25 of 46 patients (54%) had died in the REBOA and standard care group vs 18 of 43 patients (42%) in the standard care alone group (odds ratio 1.58 [95% credible interval, 0.72–3.52]; posterior probability of an odds ratio greater than 1 — indicating increased odds of death with REBOA — 86.9%). Among the ten secondary outcomes, the odds ratios for 6-month, in-hospital, and 24-, 6-, and 3-hour mortality were all increased in the REBOA group, with larger increases at earlier mortality endpoints. There were more deaths due to bleeding in the REBOA and standard care group (8 of 25 patients [32%]) than in the standard care alone group (3 of 18 patients [17%]), and most occurred within 24 hours. The authors concluded that a strategy of REBOA and standard care in the emergency department does not reduce, and may increase, mortality compared with standard care alone.

Watch out: Small trial, wide credible interval — the interval includes no effect, so this is a harm signal, not proof of harm, and the shelf prints it as exactly that. But the signal is consistent across every time point, the mechanism is plausible (balloon placement delays definitive hemorrhage control and adds ischemic burden), and there is no offsetting benefit signal anywhere in the trial. The burden of proof now sits on REBOA’s advocates, and it can only be discharged by another randomized trial.

Source: Jansen JO et al. Emergency department resuscitative endovascular balloon occlusion of the aorta in trauma patients with exsanguinating hemorrhage: the UK-REBOA randomized clinical trial. JAMA. 2023;330(19):1862–1871. PMID 37824132 · ISRCTN16184981