SourceMed · Shelf #433 in the ask interface

AI-assisted colonoscopy: adenomas found, reliably — cancers prevented, unproven

Shelf #433 · Liver & gut

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2019–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does computer-aided detection during colonoscopy find more adenomas — and does finding them prevent colorectal cancer?

Balance of the evidence

The detection claim earns LIKELY: randomized trials on three continents agree that computer-aided detection raises the adenoma detection rate (54.8% vs 40.4% in the GI-Genius trial; pooled RR 1.24, relative, across 21 trials and 18,232 patients) and roughly halves the adenoma miss rate in tandem studies. The fence is equally consistent: the extra lesions are overwhelmingly diminutive, advanced adenoma detection did not increase in the pooled analysis, nonneoplastic polypectomies rose, and no trial has measured cancer incidence or cancer death. Buy the detection claim at LIKELY; the cancer claim is not on this shelf because no one has earned it yet.

MeSH: Adenoma · Artificial Intelligence · Colonoscopy · Colorectal Neoplasms · Deep Learning · Early Detection of Cancer · Humans · Mass Screening

Cards (4)

Card 1 — GI-Genius CADe trial (Repici 2020, Gastroenterology): adenoma detection rate 54.8% with AI vs 40.4% without (RR 1.30, relative)

Study: Multicenter randomized controlled trial, Gastroenterology 2020. The registry number is printed in the record’s own abstract (ClinicalTrials.gov no. 04079478): NCT04079478.

Population: 685 subjects analyzed (mean age 61.3 years [SD 10.2]; 337 men), undergoing colonoscopy for colorectal cancer screening, post-polypectomy surveillance, or workup of a positive fecal immunochemical test or symptoms, at 3 centers in Italy.

Summary: 685 patients undergoing screening, surveillance, or FIT-positive colonoscopy at 3 Italian centers, randomized to computer-aided detection (GI-Genius) or standard high-definition colonoscopy. Adenoma detection rate: 54.8% vs 40.4% — RR 1.30 [1.14–1.45], relative . Adenomas per colonoscopy: 1.07 vs 0.71 . The gains included adenomas ≤5 mm (33.7% vs 26.5%) and 6–9 mm (10.6% vs 5.8%). Withdrawal time did not differ (417 vs 435 seconds), and resection of non-neoplastic lesions did not increase (26.0% vs 28.7%).

Result: The adenoma detection rate was significantly higher in the CADe group (54.8%) than in the control group (40.4%) (relative risk, 1.30; 95% CI, 1.14 to 1.45). Adenomas detected per colonoscopy were significantly higher with CADe (mean 1.07 [SD 1.54]) than without (mean 0.71 [SD 1.20]) (incidence rate ratio, 1.46; 95% CI, 1.15 to 1.86). There was no significant difference in withdrawal time or in the proportion of subjects with resection of non-neoplastic lesions.

Watch out: The absolute gain — about 14 more patients with an adenoma found per 100 colonoscopies — is real and consistent across this shelf’s trials. What it is made of matters: small adenomas dominate the increment, and most small adenomas never become cancers. Detection is a surrogate; the cancer endpoint is addressed in Card 4’s fence.

Source: Repici A et al. Efficacy of Real-Time Computer-Aided Detection of Colorectal Neoplasia in a Randomized Trial. Gastroenterology. 2020;159(2):512–520.e7. PMID 32371116 · NCT04079478. DOI 10.1053/j.gastro.2020.04.062

Card 2 — First CADe randomized trial (Wang 2019, Gut): adenoma detection 29.1% vs 20.3% — the gain was diminutive adenomas, and hyperplastic polyps rose too

Study: Prospective randomized controlled study (open, non-blinded), Gut 2019. Registry ID from the record’s own databank: ChiCTR-DDD-17012221. The record’s abstract does not print a mean age or sex mix, so none is stated here.

Population: 1,058 patients undergoing diagnostic colonoscopy: 536 randomized to standard colonoscopy and 522 to colonoscopy with the computer-aided detection system, in a population with a low baseline adenoma detection rate.

Summary: 1,058 patients at a Chinese center, prospectively randomized to colonoscopy with or without a real-time automatic polyp detection system (visual notice plus sound alarm). Adenoma detection rate: 29.1% vs 20.3% (P<0.001) ; adenomas per patient 0.53 vs 0.31 . The increase came from diminutive adenomas ( 185 vs 102 found ); larger adenomas did not differ significantly (77 vs 58, P=0.075). Hyperplastic polyps — not precancerous — also rose sharply (114 vs 52).

Result: The AI system significantly increased the adenoma detection rate (29.1% vs 20.3%, P<0.001) and the mean number of adenomas per patient (0.53 vs 0.31, P<0.001). This was due to a higher number of diminutive adenomas found (185 vs 102; P<0.001), while there was no statistical difference in larger adenomas (77 vs 58, P=0.075). The number of hyperplastic polyps detected was also significantly increased (114 vs 52, P<0.001). The authors noted that the cost-benefit ratio of these effects remained to be determined.

Watch out: Open and non-blinded — endoscopists knew when the machine was watching, which can change inspection behavior itself. And the lesion mix is the shelf’s recurring caution: the system is best at finding the lesions least likely to matter, and it also finds more lesions that never mattered at all (hyperplastic polyps), each of which still gets resected and sent to pathology.

Source: Wang P et al. Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study. Gut. 2019;68(10):1813–1819. PMID 30814121 · ChiCTR-DDD-17012221. DOI 10.1136/gutjnl-2018-317500

Card 3 — Tandem-colonoscopy trial (Wallace 2022, Gastroenterology): AI first halved the adenoma miss rate — 15.5% vs 32.4%

Study: Randomized tandem (back-to-back) colonoscopy trial, Gastroenterology 2022. Registry ID from the record’s own databank: NCT03954548. The record’s abstract does not print a mean age or sex mix, so none is stated here.

Population: 230 subjects undergoing colorectal cancer screening or surveillance colonoscopy at 8 centers in Italy, the UK, and the US (116 AI-first, 114 standard-first), each examined twice on the same day.

Summary: 230 patients at 8 centers (Italy, UK, US), each undergoing two same-day back-to-back colonoscopies, randomized to AI-assisted first or standard first. Adenoma miss rate: 15.5% (38 of 246 lesions) when AI went first vs 32.4% (80 of 247) when standard colonoscopy went first — adjusted OR 0.38 [0.23–0.62], relative . The advantage was largest for ≤5 mm lesions (OR 0.34) and nonpolypoid lesions (OR 0.24). Patients with no lesion found at first pass but at least one at second: 6.8% vs 29.6% .

Result: The adenoma miss rate was 15.5% (38 of 246) in the AI-first arm and 32.4% (80 of 247) in the standard-first arm (adjusted odds ratio, 0.38; 95% CI, 0.23 to 0.62). Miss rates were lower with AI first for lesions ≤5 mm (15.9% vs 35.8%; OR 0.34) and nonpolypoid lesions (16.8% vs 45.8%; OR 0.24), and in both proximal and distal colon. The mean number of adenomas found at the second colonoscopy was lower after AI first (0.33 vs 0.70, P<.001). No difference in adverse events was found.

Watch out: The tandem design is the honest way to measure misses — but note what a miss rate is: a fraction of lesions found across two passes, dominated numerically by tiny lesions. Halving the miss rate of diminutive adenomas is not the same as halving missed cancers, and this trial, like every trial on this shelf, was not designed or powered to count cancers.

Source: Wallace MB et al. Impact of Artificial Intelligence on Miss Rate of Colorectal Neoplasia. Gastroenterology. 2022;163(1):295–304.e5. PMID 35304117 · NCT03954548. DOI 10.1053/j.gastro.2022.03.007

Estimate type: adjusted estimate, as stated in the card.

Card 4 — All 21 randomized trials pooled (Hassan 2023, Annals of Internal Medicine): detection up (ADR RR 1.24, relative) — advanced adenomas not increased, nonneoplastic removals up, cancer outcomes explicitly unclear

Study: Systematic review and meta-analysis of randomized trials, Annals of Internal Medicine 2023 (PROSPERO CRD42022293181, as printed in the record). (A meta-analysis — no single age or sex mix applies; no registry ID applies to the analysis itself.)

Population: 21 randomized trials including 18,232 patients undergoing colonoscopy for polyp and cancer detection, comparing CADe-assisted with standard colonoscopy (literature to February 2023).

Summary: 21 randomized trials, 18,232 patients. Adenoma detection rate: 44.0% with CADe vs 35.9% without — RR 1.24 [1.16–1.33], relative (low-certainty evidence by the reviewers’ GRADE assessment); adenoma miss rate lower with CADe (RR 0.45, moderate certainty). But: CADe did not increase detection of advanced adenomas, and it increased removal of nonneoplastic polyps ( +0.18 polypectomies per colonoscopy ). The reviewers state plainly that the effect on cancer incidence and cancer mortality — the outcomes patients care about — remains unclear .

Result: The adenoma detection rate was higher in the CADe group (44.0% vs 35.9%; relative risk, 1.24; 95% CI, 1.16 to 1.33; low-certainty evidence), corresponding to a 55% relative reduction in adenoma miss rate (moderate-certainty evidence). More nonneoplastic polyps were removed in the CADe group (0.52 vs 0.34 per colonoscopy; mean difference 0.18). Mean inspection time increased marginally (mean difference 0.47 minutes). The reviewers concluded that CADe increases detection of adenomas but not advanced adenomas, increases unnecessary removal of nonneoplastic polyps, and that its effect on patient-important outcomes — cancer incidence and cancer-related mortality — remains unclear.

Watch out: This card carries the shelf’s fence, in the reviewers’ own words. The detection benefit is consistent and real; the chain from ‘more diminutive adenomas resected’ to ‘fewer cancers’ runs through surveillance intervals, pathology costs, and polypectomy harms that these trials did not measure, and the one lesion class closest to cancer — advanced adenomas — did not move.

Source: Hassan C et al. Real-Time Computer-Aided Detection of Colorectal Neoplasia During Colonoscopy: A Systematic Review and Meta-analysis. Ann Intern Med. 2023;176(9):1209–1220. PMID 37639719. DOI 10.7326/M22-3678