SourceMed · Shelf #5215 in the ask interface

Rapid troponin pathways discharge more chest-pain patients within hours — 0/1-hour protocol freed 45.1% from the ED versus 32.3%, and a single undetectable troponin freed 46% within 4 hours, with no excess 30-day death or infarction in either randomised trial

Shelf #5215 · Emergency & first hours

POSSIBLE (benefit) — two randomised trials show rapid troponin pathways discharge substantially more patients hours earlier with 30-day death/MI non-inferior to standard serial testing

Stamped: 2026-11-28.

Evidence published: 2019–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with chest pain, does a high-sensitivity troponin 0/1-hour pathway discharge safely compared with standard serial testing?

Balance of the evidence

POSSIBLE (benefit) — for flow, with safety shown only to a non-inferiority standard over 30 days. In RAPID-TnT (Chew DP et al., PMID: 31478763), 3,288 patients with suspected acute coronary syndrome randomised to a 0/1-hour high-sensitivity troponin T protocol versus a masked 0/3-hour protocol were discharged from the ED in 45.1% versus 32.3% of cases (p<0.001), with median ED stay 4.6 versus 5.6 hours and less functional testing (7.5% versus 11.0%); 30-day death or myocardial infarction was 1.0% in both arms (incidence rate ratio 1.06, 95% CI 0.53–2.11; non-inferiority p=0.006), and negative predictive value among those discharged was 99.6%. In LoDED (Carlton EW et al., PMID: 32371401), a single undetectable troponin plus a non-ischaemic ECG discharged 46% within 4 hours without a 30-day major adverse cardiac event versus 37% on usual care (adjusted OR 1.58, 95% CI 0.84–2.98), and no patient with an undetectable first troponin had an event within 30 days. Neither trial was powered for rare missed events beyond its non-inferiority margin, and RAPID-TnT saw more myocardial injury recognised in the rapid arm. POSSIBLE (benefit): rapid troponin pathways safely speed discharge in two randomised trials; the benefit is hours and avoided tests, not lives.

MeSH: Acute Coronary Syndrome/blood,diagnosis,mortality,therapy · Aged · Australia · Biomarkers/blood · Cardiology Service, Hospital · Cause of Death · Emergency Service, Hospital · Female · Humans · Male · Middle Aged · Myocardial Infarction/blood,diagnosis,mortality,therapy · Predictive Value of Tests · Prognosis · Prospective Studies · Risk Factors · Time Factors · Troponin T/blood · Workflow

Cards (3)

Card 1 — RAPID-TnT 2019: 0/1-hour protocol discharged 45.1% from the ED versus 32.3% on 0/3-hour standard care — 30-day death or MI 1.0% in both arms, non-inferior

Study: Randomised trial (Chew 2019, RAPID-TnT)

Population: 3,378 patients presenting to emergency departments in Australia with suspected acute coronary syndrome (3,288 analysed; median age 59 years, 47% female), randomised August 2015–April 2019 to a 0/1-hour high-sensitivity cardiac troponin T protocol reported to the limit of detection (<5 ng/L) or to a masked 0/3-hour protocol reported to ≤29 ng/L, followed for 30 days.

Summary: RAPID-TnT 2019: 0/1-hour protocol discharged 45.1% from the ED versus 32.3% on 0/3-hour standard care — 30-day death or MI 1.0% in both arms, non-inferior

Result: Discharge from the ED: 45.1% on the 0/1-hour protocol versus 32.3% on standard care (p<0.001); median ED length of stay 4.6 hours (IQR 3.4–6.4) versus 5.6 hours (4.0–7.1) (p<0.001); functional cardiac testing 7.5% versus 11.0% (p<0.001). The 30-day primary endpoint of all-cause death or myocardial infarction occurred in 17/1,646 (1.0%) versus 16/1,642 (1.0%) (incidence rate ratio 1.06, 95% CI 0.53–2.11; non-inferiority p=0.006 against a 0.5% absolute margin; superiority p=0.867). Negative predictive value among discharged patients was 99.6% (95% CI 99.0–99.9%). More myocardial injury was recognised in the 0/1-hour arm.

Watch out: Non-inferiority was declared against a 0.5% absolute margin in a population whose event rate was only 1.0% — the trial cannot exclude a small absolute excess of missed events, and the extra myocardial injury it unmasked has no agreed management pathway yet.

Source: Chew DP et al. A Randomized Trial of a 1-Hour Troponin T Protocol in Suspected Acute Coronary Syndromes: The Rapid Assessment of Possible Acute Coronary Syndrome in the Emergency Department With High-Sensitivity Troponin T Study (RAPID-TnT). Circulation. 2019. PMID: 31478763. Registry ID: ACTRN12615001379505 (stated in the record's abstract). MeSH: Acute Coronary Syndrome/blood,diagnosis,mortality,therapy · Aged · Australia · Biomarkers/blood · Cardiology Service, Hospital · Cause of Death · Emergency Service, Hospital · Female · Humans · Male · Middle Aged · Myocardial Infarction/blood,diagnosis,mortality,therapy · Predictive Value of Tests · Prognosis · Prospective Studies · Risk Factors · Time Factors · Troponin T/blood · Workflow

Card 2 — LoDED 2020: single undetectable troponin plus normal ECG discharged 46% within 4 hours with no 30-day event, versus 37% on usual care (adjusted OR 1.58, CI crossing 1)

Study: Randomised controlled trial (Carlton 2020, LoDED)

Population: 632 adults (629 analysed; mean age 53.8 years, 41% women) presenting to eight UK hospitals with chest pain, a non-ischaemic ECG, peak symptoms <6 hours earlier, and a clinician intending ACS rule-out investigations, randomised June 2018–March 2019 to the LoDED strategy (discharge if the presentation high-sensitivity troponin was undetectable) or the usual rule-out strategy.

Summary: LoDED 2020: single undetectable troponin plus normal ECG discharged 46% within 4 hours with no 30-day event, versus 37% on usual care (adjusted OR 1.58, CI crossing 1)

Result: The primary outcome — discharge within 4 hours of arrival without a major adverse cardiac event within 30 days — occurred in 141/309 (46%) on LoDED versus 114/311 (37%) on usual care (pooled adjusted OR 1.58, 95% CI 0.84–2.98). Overall 7% of patients had a major adverse cardiac event within 30 days; no patient with an initial undetectable troponin had one within 30 days.

Watch out: The adjusted odds ratio's confidence interval crosses 1 and the authors note effectiveness varied between hospitals and depended on how good each site's usual pathway already was — the strategy adds most where baseline practice is slowest.

Source: Carlton EW et al. Limit of detection of troponin discharge strategy versus usual care: randomised controlled trial. Heart. 2020. PMID: 32371401. Registry ID: ISRCTN86184521. MeSH: Acute Coronary Syndrome/blood,diagnosis,therapy · Adult · Aged · Angina Pectoris/blood,diagnosis,therapy · Biomarkers/blood · Cardiology Service, Hospital · Clinical Decision Rules · Electrocardiography · Emergency Service, Hospital · Female · Humans · Length of Stay · Male · Middle Aged · Patient Discharge · Predictive Value of Tests · Prospective Studies · Risk Assessment · Risk Factors · Time Factors · Troponin/blood · United Kingdom

Estimate type: adjusted estimate, as stated in the card.

Card 3 — Synthesis: two randomised pathway trials agree — hours saved and tests avoided, safety to a 30-day non-inferiority standard, no outcome benefit beyond flow

Study: Synthesis

Population: Two randomised trials totalling about 3,900 emergency-department patients with suspected acute coronary syndrome (RAPID-TnT, Australia, n=3,288 analysed; LoDED, UK, n=629 analysed), each testing a rapid high-sensitivity troponin discharge strategy against standard serial testing.

Summary: Synthesis: two randomised pathway trials agree — hours saved and tests avoided, safety to a 30-day non-inferiority standard, no outcome benefit beyond flow

Result: Early discharge rose from 32.3% to 45.1% (ED discharge, RAPID-TnT) and from 37% to 46% (discharge within 4 hours without a 30-day event, LoDED). Thirty-day death or myocardial infarction was 1.0% in both RAPID-TnT arms (non-inferiority p=0.006); no LoDED patient with an undetectable first troponin had a 30-day event. POSSIBLE (benefit): the proven gain is speed and avoided downstream testing, at a safety standard of non-inferiority over 30 days.

Watch out: Both trials predate widespread 0/1-hour adoption as usual care, so the incremental gain over a modern standard pathway is smaller than the gain over the comparators tested; neither trial addresses the management of the extra myocardial injury rapid reporting detects. Single-programme strategy evidence in a relaxed-intake band — Tier C set.

Source: Synthesis of Chew DP et al. Circulation. 2019 (PMID: 31478763); Carlton EW et al. Heart. 2020 (PMID: 32371401).