Broken finger or thumb: buddy taping matched splinting for children's reduced finger fractures, splint choice changed mallet-finger failure rates, and one small trial favoured a wire over a splint patients kept removing
Shelf #5322 · Emergency & first hours
SPLIT — children's reduced phalangeal fractures: buddy taping non-inferior to splinting in one RCT (81 children) and more comfortable · mallet finger: no difference in final extensor lag between splint types in one RCT (64 patients), but failure 23.8% with Stack and dorsal splints versus 0% with a custom thermoplastic splint · mallet finger wire versus splint: Kirschner wire beat Stack splint in one small randomised comparison (41 patients), driven by splint non-compliance
Stamped: 2026-11-28.
Evidence published: 2011–2026.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
I've broken my finger or thumb — should it be buddy-taped, splinted, or fixed with an operation, and does the choice change how well it heals?
Balance of the evidence
SPLIT — the answer depends on which finger injury is being treated, because the comparative evidence is injury-specific. For displaced extra-articular finger fractures in children that have been put back into place (closed reduction), one randomised trial (Weber 2025, PMID: 39487748; 81 children) found buddy taping non-inferior to splinting for keeping the fracture aligned, and more comfortable; a systematic review of children's Salter-Harris II finger fractures (Sohail 2026, PMID: 40304136) found every fracture healed without complications whichever method was used. For mallet finger (the fingertip droops because the extensor tendon is injured, with or without a small fracture), a multicentre randomised trial (O'Brien 2011, PMID: 21272714; 64 patients) found no difference in the final droop between three splint types, but treatment failure was 23.8% with a Stack splint and 23.8% with a dorsal aluminium splint versus 0% with a custom thermoplastic splint. And in one small randomised comparison (Mendoza 2022, PMID: 35572082; 41 patients), a Kirschner wire outperformed a Stack splint for mallet finger — but mainly because most splint patients did not keep the splint on. BOUNDARY: this shelf cards only the comparative immobilisation and wire-versus-splint evidence actually found. Fractures needing surgery for other reasons (open fractures, joint involvement, rotation that cannot be corrected) and thumb fractures specifically have no comparative trial carded here — no randomised comparison for thumb fractures was found. SPLIT: taping and splinting look equivalent for children's reduced finger fractures; for mallet finger the splint must fit and be worn, and a wire beat a poorly worn splint in one small study.
MeSH: Adolescent · Athletic Tape · Child · Child, Preschool · Female · Finger Injuries/surgery · Finger Injuries/therapy · Finger Phalanges/injuries · Fractures, Bone/surgery · Fractures, Bone/therapy · Humans · Male · Range of Motion, Articular · Splints
Cards (5)
Card 1 — Weber 2025 (children's finger fractures): buddy taping was non-inferior to splinting after closed reduction — displacement 3 versus 5 — and significantly more comfortable
Study: Randomised non-inferiority trial (Weber 2025)
Population: 81 children aged 4–16 years with displaced extra-articular fractures of the proximal or middle phalanx, treated with closed reduction and then randomised to buddy taping (43 children) or splinting (38 children).
Summary: Weber 2025 (children's finger fractures): buddy taping was non-inferior to splinting after closed reduction — displacement 3 versus 5 — and significantly more comfortable
Result: Secondary displacement occurred in 3 children in the taping group and 5 in the splinting group; the risk difference fell below the predefined 10% non-inferiority margin, so taping was non-inferior to splinting for maintaining alignment. Comfort was significantly higher with taping. There were no differences between the groups in analgesic use or in total active motion at 6 months.
Watch out: One trial, 81 children, one fracture pattern (displaced extra-articular proximal/middle phalangeal fractures that had already been successfully reduced). It does not cover fractures that could not be reduced, fractures into the joint, thumb fractures, or adults. Non-inferiority within a 10% margin is not proof of exact equality — it rules out taping being worse by more than that margin on this outcome.
Source: Weber et al. Buddy taping versus splinting for displaced extra-articular phalangeal fractures in children. J Hand Surg Eur Vol. 2025. PMID: 39487748. Registry ID: NCT04068935. MeSH: Adolescent · Athletic Tape · Child · Child, Preschool · Female · Finger Injuries/surgery · Finger Injuries/therapy · Finger Phalanges/injuries · Fractures, Bone/surgery · Fractures, Bone/therapy · Humans · Male · Range of Motion, Articular · Splints
Card 2 — Sohail 2026 (systematic review, children's Salter-Harris II finger fractures): every fracture healed with no complications under nonsurgical care; the included RCT found less displacement, better comfort and lower cost with taping
Study: Systematic review of nonsurgical treatment (Sohail 2026)
Population: 5 studies (1 randomised trial, 3 prospective, 1 retrospective) of nonsurgical treatment of Salter-Harris II fractures of the proximal or middle phalanx in children, comparing taping and splinting approaches.
Summary: Sohail 2026 (systematic review, children's Salter-Harris II finger fractures): every fracture healed with no complications under nonsurgical care; the included RCT found less displacement, better comfort and lower cost with taping
Result: Across the included studies all fractures healed, there were no complications, and range of motion was full or near-full. The included randomised trial (Weber 2019, 99 children) found secondary displacement in 1 of 52 taped children versus 3 of 47 splinted children, near-identical total active motion (259 degrees versus 262 degrees, P=.51), better early comfort with taping (visual analogue score 0.9 versus 2.0 at 5 days, P=.01), and lower cost (38 euros versus 160 euros). The review's authors concluded that small samples and heterogeneity prevented a conclusive recommendation between taping and splinting.
Watch out: This review overlaps the Weber 2025 card above (a related trial from the same research area) — it is corroboration, not a wholly independent body of evidence. The review's abstract reports the Weber 2019 displacement comparison in percentage terms that differ from the counts in the full text; the counts (1/52 versus 3/47) are what is printed on this card. Growth-plate (Salter-Harris) fractures in children only — nothing here transfers directly to adult finger fractures.
Source: Sohail et al. Nonsurgical treatment of Salter-Harris II fractures of the proximal and middle phalanx in children: a systematic review. Hand (N Y). 2026. PMID: 40304136. Registry ID: none in the record (systematic review). MeSH: Athletic Tape · Child · Finger Injuries/therapy · Finger Phalanges/injuries · Fractures, Bone/therapy · Humans · Salter-Harris Fractures/therapy · Splints
Card 3 — O'Brien 2011 (mallet finger splints): no difference in final droop between three splints — but failure was 23.8% with Stack and dorsal splints versus 0% with a custom thermoplastic splint
Study: Multicentre single-blind randomised trial (O'Brien 2011)
Population: 64 patients with acute type 1a/1b mallet finger, randomised to a Stack splint, a dorsal padded aluminium splint, or a custom-made thermoplastic thimble splint; all splints were worn continuously for 8 weeks followed by a 4-week graduated withdrawal.
Summary: O'Brien 2011 (mallet finger splints): no difference in final droop between three splints — but failure was 23.8% with Stack and dorsal splints versus 0% with a custom thermoplastic splint
Result: There was no difference between the splints in extensor lag (the residual fingertip droop) at 12 or 20 weeks. Treatment failure, however, occurred in 23.8% of the Stack group and 23.8% of the dorsal aluminium group versus 0% of the custom thermoplastic group (P=.04). There was a medium negative correlation between compliance and extensor lag — patients who wore their splint more had less droop. There were no differences in satisfaction or pain between the groups.
Watch out: 64 patients across three arms means roughly 21 per splint — the 0% failure figure for the custom splint rests on a small denominator and could shift with a few events. The trial compares splint designs, all worn for the same 8 weeks; it does not test shorter wear, night-only wear, or surgery. Mallet finger here is the tendon injury pattern (type 1a/1b); large fracture fragments with joint subluxation are a different problem.
Source: O'Brien et al. A randomised trial of splinting for mallet finger. Archives of Physical Medicine and Rehabilitation. 2011. PMID: 21272714. Registry ID: NCT00310570. MeSH: Adolescent · Adult · Aged · Aluminum · Analysis of Variance · Female · Finger Injuries/diagnostic imaging · Finger Injuries/rehabilitation · Humans · Male · Middle Aged · Plastics · Prospective Studies · Radiography · Single-Blind Method · Splints · Tendon Injuries/diagnostic imaging · Tendon Injuries/rehabilitation · Treatment Outcome · Wounds, Nonpenetrating/diagnostic imaging · Wounds, Nonpenetrating/rehabilitation
Card 4 — Mendoza 2022 (mallet finger, wire versus splint): 17 of 19 wired fingers recovered fully; only 7 of 22 splinted fingers completed treatment successfully — non-compliance drove the splint failures
Study: Randomised comparison (Mendoza Velez 2022)
Population: 41 patients (mean age 43 years) with acute closed mallet finger (Doyle type I), randomised to Kirschner wire fixation (19 patients) or a Stack splint (22 patients), with treatment for about 6 weeks.
Summary: Mendoza 2022 (mallet finger, wire versus splint): 17 of 19 wired fingers recovered fully; only 7 of 22 splinted fingers completed treatment successfully — non-compliance drove the splint failures
Result: 17 of the 19 patients treated with a Kirschner wire completed treatment with full recovery. In the Stack splint group only 7 of 22 completed treatment with success and 15 relapsed. The splint failures were driven by non-compliance — patients removing or not wearing the splint as instructed.
Watch out: A single small study (41 patients), and its comparison is not purely wire versus splint: it is wire versus a splint that most patients did not wear properly (only about 61% of splint patients returned at 3 weeks in the full text). Read alongside the O'Brien card — where a well-fitting custom splint had no failures — the lesson may be about achieving continuous immobilisation by any means, not about wires being inherently superior.
Source: Mendoza Velez et al. Kirschner wire versus Stack splint for acute closed mallet finger (Doyle I): a randomised comparison. Plast Surg (Oakv). 2022. PMID: 35572082. Registry ID: none in the record. MeSH: not captured from the record
Card 5 — Synthesis: for children's reduced finger fractures, taping does the splint's job more comfortably; for mallet finger, continuous immobilisation is what matters — and the splint patients actually wear beats the one they remove
Study: Synthesis
Population: Four sources: a randomised non-inferiority trial in 81 children (Weber 2025), a systematic review of 5 studies in children (Sohail 2026), a multicentre randomised splint trial in 64 mallet-finger patients (O'Brien 2011), and a small randomised wire-versus-splint comparison in 41 mallet-finger patients (Mendoza 2022).
Summary: Synthesis: for children's reduced finger fractures, taping does the splint's job more comfortably; for mallet finger, continuous immobilisation is what matters — and the splint patients actually wear beats the one they remove
Result: Children's displaced extra-articular phalangeal fractures after closed reduction: taping non-inferior to splinting for secondary displacement (3 versus 5 events; Weber 2025), with all fractures healing across the review's studies (Sohail 2026). Mallet finger: final extensor lag did not differ between three splint designs, but failure was 23.8% with Stack and dorsal aluminium splints versus 0% with a custom thermoplastic splint (O'Brien 2011); a Kirschner wire achieved full recovery in 17 of 19 patients versus 7 of 22 completing successfully with a Stack splint, with non-compliance the main driver (Mendoza 2022). SPLIT — equivalence for taping versus splinting in the paediatric fracture tested; for mallet finger, the method that guarantees 6–8 weeks of continuous immobilisation wins, whichever method that is.
Watch out: This shelf does not cover thumb fractures (no comparative trial found), fractures involving the joint surface, open fractures, or fractures with rotation or shortening that cannot be corrected closed — those follow surgical judgement, not these cards. Every comparative study carded is small (41–99 participants); the direction of the findings is consistent, but none of them is definitive alone.
Source: Synthesis of Weber et al. J Hand Surg Eur Vol. 2025 (PMID: 39487748); Sohail et al. Hand (N Y). 2026 (PMID: 40304136); O'Brien et al. Archives of Physical Medicine and Rehabilitation. 2011 (PMID: 21272714); Mendoza Velez et al. Plast Surg (Oakv). 2022 (PMID: 35572082).