SourceMed · Shelf #5462 in the ask interface

Post-flight orthostatic intolerance: compression garments held standing heart rate and pressure at pre-flight levels — fluid loading helps for 1–3 hours, and midodrine failed in 2 of 5 astronauts tested

Shelf #5462 · Adherence & how care is delivered

SPLIT (compression garments: POSSIBLE benefit · fluid loading: POSSIBLE partial benefit · midodrine in flight: unproven)

Stamped: 2026-11-28.

Evidence published: 2010–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In astronauts returning from spaceflight, do fluid loading, midodrine or gradient compression garments prevent post-flight orthostatic intolerance?

Balance of the evidence

Post-flight orthostatic intolerance countermeasures. Gradient compression garments have the strongest flight data: Stenger 2013 (PMID: 23713210; 14 Shuttle astronauts) — heart-rate rise 11 vs 21 beats/min and systolic change +2 vs −9 mmHg on landing day; Lee 2020 (PMID: 32765292; 11 long-duration astronauts) — standing responses held at pre-flight levels while wearing the garment. Fluid loading rests on a head-down-tilt analogue (Cowings 2015; n=16) showing a 10 mmHg pressure advantage confined to hours 1–3. Midodrine's only flight test (Platts, NASA report; n=5) failed to prevent hypotension in 2 of 5 and routine use was judged unlikely. Terrestrial midodrine shelves #2498/#1557 are cross-pointed, not re-carded. SPLIT.

MeSH: Adult · Male · Hemodynamics · Middle Aged · Sodium Chloride · Body Fluids · Head-Down Tilt · Young Adult · Aerospace Medicine · Humans · Female · Monitoring, Physiologic

Cards (5)

Card 1 — Cowings 2015 (head-down-tilt analogue, labelled analogue): salt-and-water fluid loading raised mean arterial pressure by 10 mmHg in hours 1–3 — the window 1–3 hours before re-entry

Study: Head-down-tilt analogue crossover study (Cowings 2015)

Population: ANALOGUE (head-down tilt simulation, not flight data): 16 subjects given two 6-hour exposures to head-down tilt, with and without fluid loading (salt tablets and water), to simulate microgravity's plasma-volume effects.

Summary: Cowings 2015 (head-down-tilt analogue, labelled analogue): salt-and-water fluid loading raised mean arterial pressure by 10 mmHg in hours 1–3 — the window 1–3 hours before re-entry

Result: Significant increases in mean arterial pressure occurred between hours 1 and 3 of head-down tilt after fluid loading (10 mmHg higher than without fluid loading). Other cardiovascular responses showed non-significant trends with similar time profiles. The authors concluded the optimal time to begin fluid loading is within 1 to 3 hours before re-entry, while noting large individual variability suggesting fluid loading alone may be inadequate for all crewmembers.

Watch out: A 6-hour tilt analogue in 16 ground subjects: it times the fluid load, it does not show that fluid loading prevents post-flight presyncope in astronauts.

Source: Cowings PS et al. Fluid Loading Effects on Temporal Profiles of Cardiovascular Responses to Head-Down Tilt. Aerosp Med Hum Perform. 2015. PMID: not captured. Registry ID: none in the record. MeSH: Adult · Male · Hemodynamics · Middle Aged · Sodium Chloride · Body Fluids · Head-Down Tilt · Young Adult · Aerospace Medicine · Humans · Female · Monitoring, Physiologic

Card 2 — Platts (midodrine, flight): taken before re-entry, midodrine did not prevent post-flight hypotension in 2 of 5 astronauts (n=5 on the face), and routine use was judged unlikely

Study: Uncontrolled flight study in 5 astronauts (Platts 2010)

Population: Five male astronauts (n=5) whose cardiovascular responses to 10 minutes of 80° head-up tilt were compared before flight and within 60 minutes of Space Shuttle landing (in the Crew Transport Vehicle on the runway); midodrine was self-administered before re-entry. A preceding phase had given 10 mg midodrine 2 hours after landing, 1 hour before a laboratory tilt test.

Summary: Platts (midodrine, flight): taken before re-entry, midodrine did not prevent post-flight hypotension in 2 of 5 astronauts (n=5 on the face), and routine use was judged unlikely

Result: Midodrine did not prevent post-flight orthostatic hypotension in two of the five astronauts, but the rate of presyncope across the group did not increase from pre- to post-flight (p=0.17). Systolic blood pressure decreased more after spaceflight (p=0.05) and diastolic tended to decrease (p=0.08); the heart-rate change from supine to standing was unaffected. The authors concluded that, with no control subjects tested in the vehicle, and with drug-interaction concerns (antiemetics) and QTc prolongation seen in long-duration astronauts, routine midodrine use for immediate post-flight hypotension is unlikely.

Watch out: No untreated comparison in the same setting and only 5 subjects: this can raise doubts about midodrine, it cannot quantify any benefit. Terrestrial midodrine evidence is homed on Shelves #2498 and #1557 and is not re-carded here.

Source: Platts SH et al. [Midodrine as a Countermeasure to Orthostatic Hypotension Immediately After Space Shuttle Landing — bracketed descriptive title; NASA technical report]. NASA Technical Reports Server. 2010. PMID: not captured. Registry ID: none in the record. MeSH: not captured from the record

Card 3 — Stenger 2013: an abdomen-high gradient compression garment blunted the landing-day stand-test response — heart rate rise 11 versus 21 beats/min, systolic pressure +2 versus −9 mmHg

Study: Controlled stand-test study in Shuttle astronauts (Stenger 2013)

Population: 14 astronauts around Space Shuttle missions (12–16 days) performing a 3.5-minute stand test ~30 days before flight (no garment) and ~2 hours after flight: 7 wore a custom three-piece foot-to-breast gradient compression garment (55 mmHg at the ankle grading to 15 mmHg over the abdomen) and 7 were controls.

Summary: Stenger 2013: an abdomen-high gradient compression garment blunted the landing-day stand-test response — heart rate rise 11 versus 21 beats/min, systolic pressure +2 versus −9 mmHg

Result: On landing day the garment group had a smaller rise in heart rate on standing (11±1 vs 21±4 beats/min, p≤0.05) and no fall in systolic blood pressure (+2±4 vs −9±2 mmHg, p≤0.05). No subject in either group became presyncopal during the short stand test, before or after flight. The authors concluded the garment prevented the tachycardia and hypotension typically seen post-spaceflight in this small group.

Watch out: The 3.5-minute stand test was deliberately too short to provoke presyncope, so the garment is proven on physiology, not on preventing fainting; Shuttle flights were short-duration.

Source: Stenger MB et al. Abdomen-high elastic gradient compression garments during post-spaceflight stand tests. [Journal not captured from the record]. 2013. PMID: 23713210. Registry ID: none in the record. MeSH: not captured from the record

Card 4 — Lee 2020: after ~6-month missions, a gradient compression garment kept landing-day standing heart rate and pressure responses at pre-flight levels in 11 astronauts

Study: Within-subject flight study in long-duration astronauts (Lee 2020)

Population: 11 astronauts (9 men, 2 women) after long-duration spaceflight, tested prone-then-standing (3.5 minutes) before flight in standard clothing and on landing day wearing a lower-body gradient compression garment at 1–4 hours, ~12 hours and ~28 hours after landing; historically, >60% of returning long-duration astronauts could not complete a 10-minute 80° tilt test on landing day.

Summary: Lee 2020: after ~6-month missions, a gradient compression garment kept landing-day standing heart rate and pressure responses at pre-flight levels in 11 astronauts

Result: Three astronauts were unable to attempt the stand test at the first landing-day session and one could not complete standing at the second. In those tested, heart rate and mean arterial pressure responses to standing while wearing the garment were not different from pre-flight at any landing-day session. The authors concluded the garment prevented the tachycardia that normally occurs on standing after spaceflight without compression and protected against a fall in blood pressure during the short stand test.

Watch out: No randomised no-garment landing-day arm (the comparison is to pre-flight responses and historical experience), and the frailest crew — those unable to attempt the test — are missing from the physiology.

Source: Lee SMC et al. Efficacy of Gradient Compression Garments in the Hours After Long-Duration Spaceflight. Front Physiol. 2020. PMID: 32765292. Registry ID: none in the record. MeSH: not captured from the record

Card 5 — Synthesis: compression garments work on landing-day physiology; fluid loading is a timing-limited partial measure; midodrine is unproven in flight — SPLIT

Study: Synthesis

Population: Synthesis of the cards above: Cowings 2015 (16 analogue subjects), Platts 2010 (5 astronauts), Stenger 2013 (14 astronauts) and Lee 2020 (11 astronauts).

Summary: Synthesis: compression garments work on landing-day physiology; fluid loading is a timing-limited partial measure; midodrine is unproven in flight — SPLIT

Result: Gradient compression garments are the best-supported countermeasure: they abolished the excess tachycardia and systolic fall on standing after both short (Stenger) and long (Lee) missions. Fluid loading raises arterial pressure for a 1–3 hour window in analogue studies but is acknowledged to be inadequate alone. Midodrine, effective in terrestrial orthostatic hypotension (Shelves #2498, #1557), failed to prevent hypotension in 2 of 5 astronauts in its only flight test and carries QTc/antiemetic interaction concerns. SPLIT (compression: POSSIBLE benefit · fluid loading: POSSIBLE partial benefit · midodrine in flight: unproven).

Watch out: No countermeasure has been tested against the outcome that matters most — presyncope or syncope on landing day — in a randomised flight trial; all stamps here rest on stand-test physiology.

Source: Synthesis of Cowings et al. 2015, Platts et al. 2010 (NASA technical report), Stenger et al. 2013 (PMID: 23713210) and Lee et al. 2020 (PMID: 32765292).