Spinning as medicine: 30 minutes a day in a small centrifuge blunted fainting-proneness after 60 days of bed rest (standing tolerance fell ~300 vs 801 seconds) — but it did not protect blood volume or fitness, and spinning while exercising added nothing

Shelf #5467 · Adherence & how care is delivered

SPLIT (daily centrifugation at rest blunted orthostatic losses in bed-rest analogues — presyncope time fell ~300 s vs 801 s in controls · no protection of plasma volume or aerobic power, and no added benefit over exercise alone)

Stamped: 2026-11-28.

Evidence published: 2015–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does artificial gravity from short-radius (short-arm) centrifugation, daily or combined with exercise, protect against cardiovascular and other deconditioning during spaceflight or its head-down bed-rest analogue?

Balance of the evidence

SPLIT — a real orthostatic benefit at rest in analogues; no protection for plasma volume or fitness, and no added benefit when combined with exercise. Linnarsson 2015 (PMID: 25342708; 11 men, crossover) found tilt tolerance after 5 days of bed rest was 78% of baseline with 6 × 5 min daily centrifugation versus 36% with no countermeasure, while plasma volume (85% of baseline) and aerobic power (95%) were unprotected. Hoenemann 2023 (PMID: 37347452; DRKS00015677; AGBRESA, 24 people, 60 days) found time to presyncope fell ~300 s in both centrifugation groups versus 801 s in controls (P = 0.0249). Hedge 2025 (PMID: 40953072; BRACE, 24 men, 60 days) found exercise during centrifugation protected aerobic fitness exactly as exercise alone did (Δ +4% vs 0%, controls −24%) and standing tolerance fell in all groups. SPLIT (orthostatic tolerance at rest: POSSIBLE benefit in analogues · plasma volume, fitness, and exercise-combined use: the treatment made no difference beyond exercise).

MeSH: Adult · Bed Rest/adverse effects · Blood Volume/physiology · Cross-Over Studies · Gravity, Altered · Humans · Male · Orthostatic Intolerance/etiology · Orthostatic Intolerance/physiopathology · Orthostatic Intolerance/therapy · Supine Position · Treatment Outcome

Cards (4)

Card 1 — Linnarsson 2015 (BR-AG1): split-dose centrifugation preserved standing tolerance best — tilt tolerance was 78% of baseline with 6 × 5 min daily spins vs 36% with no countermeasure after 5 days of bed rest

Study: Randomised crossover trial in a bed-rest analogue (Linnarsson 2015)

Population: 11 healthy men in a randomised crossover of three 5-day head-down bed-rest campaigns: no countermeasure, 30 min of artificial gravity once daily (AG1), or 6 × 5 min daily (AG2), at 1 G at the centre of mass; complete datasets in 8 subjects.

Summary: Linnarsson 2015 (BR-AG1): split-dose centrifugation preserved standing tolerance best — tilt tolerance was 78% of baseline with 6 × 5 min daily spins vs 36% with no countermeasure after 5 days of bed rest

Result: After bed rest, head-up tilt tolerance times were 36% (control), 64% (AG1) and 78% (AG2) of pre-bed-rest baseline, with a significant difference between AG2 and control. Plasma volume fell to 85% and peak oxygen uptake to 95% of baseline with no differences between treatments. AG2 was better tolerated than AG1.

Watch out: Five days of bed rest in 11 men (8 complete datasets) is a very short, small analogue: it shows an orthostatic signal for split-dose spinning, not protection over a 6-month mission, and neither plasma volume nor aerobic power was protected at all.

Source: Linnarsson D et al. Effects of an artificial gravity countermeasure on orthostatic tolerance, blood volumes and aerobic power after short-term bed rest (BR-AG1). Journal of Applied Physiology. 2015. PMID: 25342708. Registry ID: none in the record. MeSH: Adult · Bed Rest/adverse effects · Blood Volume/physiology · Cross-Over Studies · Gravity, Altered · Humans · Male · Orthostatic Intolerance/etiology · Orthostatic Intolerance/physiopathology · Orthostatic Intolerance/therapy · Supine Position · Treatment Outcome

Card 2 — Hoenemann 2023 (AGBRESA): daily centrifugation blunted the fall in time to presyncope after 60 days of bed rest — a fall of ~300 s in both spin groups vs 801 s in controls (P = 0.0249)

Study: Controlled trial in a 60-day bed-rest analogue (Hoenemann 2023)

Population: 24 healthy people (8 women; age 33.3 ± 9.0 years) in the 60-day strict head-down tilt AGBRESA bed-rest study, assigned to 30 min/day continuous centrifugation, 6 × 5 min intermittent centrifugation (both 1 Gz at the centre of mass), or control.

Summary: Hoenemann 2023 (AGBRESA): daily centrifugation blunted the fall in time to presyncope after 60 days of bed rest — a fall of ~300 s in both spin groups vs 801 s in controls (P = 0.0249)

Result: Time to presyncope on tilt testing fell by 323 ± 235 s (continuous) and 296 ± 508 s (intermittent) versus 801 ± 354 s in controls (P = 0.0249 between interventions). Supine and upright heart rate still rose in all groups, and the orthostatic benefit was not correlated with changes in plasma volume — centrifugation attenuated, but did not prevent, cardiovascular deconditioning.

Watch out: Still an analogue with 8 people per group and wide variability (the intermittent group's SD of 508 s exceeds its mean effect); baseline orthostatic tolerance differed between groups, and no in-flight centrifuge trial exists.

Source: Hoenemann JN et al. Effects of daily artificial gravity training on orthostatic tolerance following 60-day strict head-down tilt bedrest. Clinical Autonomic Research. 2023. PMID: 37347452. Registry ID: DRKS00015677. MeSH: not captured from the record

Card 3 — Hedge 2025 (BRACE): exercising while spinning protected aerobic fitness exactly as well as exercise alone — and neither protected standing tolerance, which fell in every group

Study: Randomised controlled trial in a 60-day bed-rest analogue (Hedge 2025)

Population: 24 healthy men (age 29 ± 6 years) randomised for 60 days of head-down bed rest to sedentary control (n = 8), high-intensity interval cycling exercise (n = 8), or the same exercise performed while spinning in a short-arm centrifuge (exercise + AG, n = 8); exercise on 49 of 60 days.

Summary: Hedge 2025 (BRACE): exercising while spinning protected aerobic fitness exactly as well as exercise alone — and neither protected standing tolerance, which fell in every group

Result: Peak oxygen uptake fell 24 ± 5% in controls but was protected by exercise (Δ 0 ± 6%) and by exercise + AG (Δ +4 ± 6%; HDBR × group P < 0.001) — no added benefit from spinning during exercise. Time to presyncope fell in all groups: control −9.0 ± 3.4 min, exercise −12.4 ± 5.2 min, exercise + AG −4.5 ± 8.8 min (main effect P < 0.001). The authors conclude AG should be applied at rest or after exercise, not during it, to protect orthostatic tolerance.

Watch out: The exercise + AG orthostatic figure (−4.5 min) looks gentler but carries an 8.8-minute SD in 8 men, and the trial's own interpretation is that muscle-pump activity during exercise cancels the centrifuge's orthostatic stimulus — timing, not spinning itself, is the open question.

Source: Hedge ET et al. Exercise during artificial gravity preserves cardiorespiratory fitness but not orthostatic tolerance following 60 days of head-down bed rest (BRACE). Journal of Applied Physiology. 2025. PMID: 40953072. Registry ID: none in the record. MeSH: not captured from the record

Card 4 — Synthesis: centrifugation at rest genuinely blunts orthostatic intolerance in bed-rest analogues; it does not protect plasma volume or fitness, and spinning during exercise adds nothing

Study: Synthesis

Population: The carded evidence: three randomised analogue trials — 5-day crossover (11 men), 60-day AGBRESA (24 people) and 60-day BRACE (24 men).

Summary: Synthesis: centrifugation at rest genuinely blunts orthostatic intolerance in bed-rest analogues; it does not protect plasma volume or fitness, and spinning during exercise adds nothing

Result: Orthostatic tolerance after bed rest: 78% of baseline preserved with split-dose spins vs 36% without (Linnarsson 2015); time-to-presyncope losses of ~300 s with daily spins vs 801 s in controls at 60 days (Hoenemann 2023). But plasma volume and aerobic power were unprotected by spinning alone (Linnarsson 2015), and exercising on the centrifuge matched exercise alone for fitness while standing tolerance still fell in every group (Hedge 2025). No trial has flown a centrifuge with crew. SPLIT.

Watch out: All three trials are head-down bed-rest analogues; the same AGBRESA campaign also found 30 min of daily centrifugation did not prevent optic disc edema, so artificial gravity at this dose is a cardiovascular countermeasure signal, not a whole-body solution.

Source: Synthesis of Linnarsson D et al. Journal of Applied Physiology. 2015 (PMID: 25342708); Hoenemann JN et al. Clinical Autonomic Research. 2023 (PMID: 37347452; DRKS00015677); Hedge ET et al. Journal of Applied Physiology. 2025 (PMID: 40953072).