Insulin-only bionic pancreas (iLet) in type 1 diabetes: one pivotal programme (NCT04200313) — HbA1c fell 0.5 percentage points and time in range rose 12–14% versus standard care with CGM over 13 weeks, with no increase in measured hypoglycaemia
Shelf #5529 · Diabetes, glucose & metabolism
POSSIBLE (benefit) — single trial programme (NCT04200313): HbA1c −0.5 percentage points and time in range +12–14% versus standard care with CGM at 13 weeks, hypoglycaemia non-inferior; capped at POSSIBLE because all carded reports share the one programme
Stamped: 2026-11-28.
Evidence published: 2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In type 1 diabetes, does the insulin-only bionic pancreas (iLet) improve HbA1c and time in range versus standard care with CGM?
Balance of the evidence
POSSIBLE (benefit) — a single trial programme (the Insulin-Only Bionic Pancreas Pivotal Trial, NCT04200313), so the stamp is capped at POSSIBLE despite consistent results. In the 13-week randomised trial (326 participants aged 6–79), HbA1c fell from 7.9% to 7.3% on the bionic pancreas and was unchanged at 7.7% on standard care with CGM (adjusted difference −0.5 percentage points), with time below 54 mg/dL non-inferior and no diabetic ketoacidosis in either group (Russell 2022, PMID: 36170500). The adult fast-acting-insulin-aspart report of the same programme found the same −0.5% HbA1c difference and 14% more time in range (3.4 h/day) versus standard care (Beck 2022, PMID: 36173235), and the single-arm extension, in which the former standard-care group crossed to the device, reproduced the improvement (HbA1c 7.7% to 7.1%; time in range 53% to 65%; Lynch 2022, PMID: 36173238). Severe hypoglycaemia rates did not differ significantly. The youth-specific pivotal report of this programme is homed at live shelf #561 (closed-loop umbrella) and is not re-carded here. POSSIBLE (benefit) — single trial programme.
MeSH: MeSH: Adolescent · Adult · Aged · Bionics · Blood Glucose · Blood Glucose Self-Monitoring · Child · Diabetes Mellitus, Type 1 · Glycated Hemoglobin · Humans · Hypoglycemic Agents · Insulin · Insulin Aspart · Insulin Infusion Systems · Insulin Lispro · Middle Aged · Young Adult
Cards (4)
Card 1 — Russell 2022 (NEJM pivotal trial): the insulin-only bionic pancreas cut HbA1c by 0.5 percentage points versus standard care with CGM at 13 weeks (7.9%→7.3% vs 7.7%→7.7%), with hypoglycaemia time non-inferior
Study: Multicentre randomised controlled trial — iLet pivotal programme (Russell 2022)
Population: 326 participants aged 6 to 79 years with type 1 diabetes, randomised 2:1 to the insulin-only bionic pancreas (iLet) with insulin aspart or lispro (n = 219) or standard care — any insulin-delivery method with unblinded real-time CGM (n = 107) — for 13 weeks at multiple centres; the device is initialised on body weight alone, with meal announcements but no carbohydrate counting.
Summary: Russell 2022 (NEJM pivotal trial): the insulin-only bionic pancreas cut HbA1c by 0.5 percentage points versus standard care with CGM at 13 weeks (7.9%→7.3% vs 7.7%→7.7%), with hypoglycaemia time non-inferior
Result: Glycated haemoglobin fell from 7.9% to 7.3% in the bionic-pancreas group and did not change (7.7% at both time points) in the standard-care group (mean adjusted difference −0.5 percentage points; 95% CI −0.6 to −0.3; P < 0.001). Time with glucose below 54 mg/dL did not differ significantly (adjusted difference 0.0 percentage points; 95% CI −0.1 to 0.04; P < 0.001 for non-inferiority against a 1-percentage-point limit). Severe hypoglycaemia rates were 17.7 versus 10.8 events per 100 participant-years (P = 0.39), and no diabetic ketoacidosis occurred in either group. Time in range is not reported in this record.
Watch out: Thirteen weeks only, and the comparator already included real-time CGM for everyone — the gain is over monitored standard care, but durability, and performance outside a trial with device support, are not shown here.
Source: Russell SJ et al. Multicenter, Randomized Trial of a Bionic Pancreas in Type 1 Diabetes. The New England Journal of Medicine. 2022. PMID: 36170500. Registry ID: NCT04200313. MeSH: Adolescent · Adult · Aged · Bionics · Blood Glucose · Blood Glucose Self-Monitoring · Child · Diabetes Mellitus, Type 1 · Glycated Hemoglobin · Humans · Hypoglycemic Agents · Insulin · Insulin Aspart · Insulin Infusion Systems · Insulin Lispro · Middle Aged · Young Adult
Estimate type: adjusted estimate, as stated in the card.
Card 2 — Beck 2022: in 275 adults, the bionic pancreas with fast-acting insulin aspart matched the HbA1c gain (−0.5%) and added 14% time in range (3.4 h/day) versus standard care — but was no better than the device running standard aspart/lispro
Study: Multicentre randomised controlled trial — iLet pivotal programme, adult aspart report (Beck 2022)
Population: 275 adults with type 1 diabetes (18–83 years, baseline HbA1c 5.3%–14.9%), randomised 2:2:1 to the bionic pancreas with fast-acting insulin aspart (n = 114), the bionic pancreas with aspart or lispro (n = 107), or standard care plus real-time CGM (n = 54), for 13 weeks.
Summary: Beck 2022: in 275 adults, the bionic pancreas with fast-acting insulin aspart matched the HbA1c gain (−0.5%) and added 14% time in range (3.4 h/day) versus standard care — but was no better than the device running standard aspart/lispro
Result: HbA1c fell from 7.8% to 7.1% with fast-acting aspart in the device versus 7.6% to 7.5% with standard care (adjusted difference −0.5%; 95% CI −0.7 to −0.3; P < 0.001). Time in range 70–180 mg/dL increased by 14% (3.4 h/day) and mean CGM glucose fell by 18 mg/dL versus standard care (P < 0.001), with time below 54 mg/dL non-inferior. Against the device using standard aspart/lispro there was no HbA1c difference (adjusted difference −0.0%; 95% CI −0.2 to 0.1). Severe hypoglycaemia rates did not differ among the three groups.
Watch out: This is a second report of the same pivotal programme (same registry number), not an independent replication — and its internal comparison shows the faster insulin added nothing, so the benefit belongs to the device algorithm, not the insulin choice.
Source: Beck RW et al. A Multicenter Randomized Trial Evaluating Fast-Acting Insulin Aspart in the Bionic Pancreas in Adults with Type 1 Diabetes. Diabetes Technology & Therapeutics. 2022. PMID: 36173235. Registry ID: NCT04200313. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Bionics · Blood Glucose · Blood Glucose Self-Monitoring · Diabetes Mellitus, Type 1 · Glycated Hemoglobin · Humans · Hypoglycemia · Hypoglycemic Agents · Insulin · Insulin Aspart · Insulin Lispro · Middle Aged · Pancreas · Young Adult
Estimate type: adjusted estimate, as stated in the card.
Card 3 — Lynch 2022 (extension): when 90 former standard-care participants crossed to the bionic pancreas for 13 weeks, HbA1c fell 7.7%→7.1% and time in range rose 53%→65% — the same size of gain as the randomised phase
Study: Single-arm extension study — iLet pivotal programme (Lynch 2022)
Population: 90 adults and children (age 6–71 years; 42 adults, 48 paediatric participants) from the pivotal trial's standard-care arm who, after completing the randomised phase, used the insulin-only bionic pancreas (iLet) for 13 weeks in a single-arm extension.
Summary: Lynch 2022 (extension): when 90 former standard-care participants crossed to the bionic pancreas for 13 weeks, HbA1c fell 7.7%→7.1% and time in range rose 53%→65% — the same size of gain as the randomised phase
Result: On the device, mean HbA1c fell from 7.7% to 7.1% (mean change −0.55%; P < 0.001), time in range 70–180 mg/dL rose from 53% to 65% (+12.0%; P < 0.001), and mean glucose fell from 182 to 164 mg/dL (−18 mg/dL; P < 0.001); gains were larger at higher baseline HbA1c and similar in adults and children. Time below 70 mg/dL fell by 0.50% (P = 0.02) and time below 54 mg/dL was unchanged. Two severe hypoglycaemia events (in the same participant) and one diabetic ketoacidosis event occurred.
Watch out: No concurrent control group: everyone knew they were on the new device, and only 90 of 107 standard-care participants took part — expectation and selection effects can inflate a before–after gain, which is why this card supports, but cannot substitute for, the randomised result.
Source: Lynch J et al. The Insulin-Only Bionic Pancreas Pivotal Trial Extension Study: A Multi-Center Single-Arm Evaluation of the Insulin-Only Configuration of the Bionic Pancreas in Adults and Youth with Type 1 Diabetes. Diabetes Technology & Therapeutics. 2022. PMID: 36173238. Registry ID: NCT04200313. MeSH: Adolescent · Adult · Aged · Bionics · Blood Glucose · Blood Glucose Self-Monitoring · Child · Diabetes Mellitus, Type 1 · Glucose · Glycated Hemoglobin · Humans · Hypoglycemic Agents · Insulin · Insulin Infusion Systems · Insulin, Regular, Human · Middle Aged · Pancreas · Young Adult
Card 4 — Synthesis: within one pivotal programme, the iLet bionic pancreas reproducibly improved HbA1c by about half a percentage point and time in range by 12–14% over 13 weeks versus CGM-supported standard care, without more measured hypoglycaemia
Study: Synthesis
Population: The carded evidence is one trial programme (NCT04200313): the 326-participant randomised trial, its 275-adult fast-acting-aspart randomised report, and its 90-participant single-arm extension. The programme's youth-specific report is homed at live shelf #561 and is not re-carded here.
Summary: Synthesis: within one pivotal programme, the iLet bionic pancreas reproducibly improved HbA1c by about half a percentage point and time in range by 12–14% over 13 weeks versus CGM-supported standard care, without more measured hypoglycaemia
Result: HbA1c: −0.5 percentage points versus standard care in both randomised reports (Russell 2022; Beck 2022), and −0.55% after crossover in the extension (Lynch 2022). Time in range: +14% (3.4 h/day) versus standard care in adults (Beck 2022) and +12% on crossover (Lynch 2022); the NEJM record does not report time in range. Time below 54 mg/dL was non-inferior in both randomised reports, severe hypoglycaemia did not differ significantly, and diabetic ketoacidosis was absent in the randomised phase but occurred once in the extension. POSSIBLE (benefit) — single trial programme.
Watch out: Every card shares one registry number and one sponsor programme: consistency across its own reports is not independent confirmation, and 13 weeks says nothing about years of real-world device use.
Source: Synthesis of Russell SJ et al. The New England Journal of Medicine. 2022 (PMID: 36170500); Beck RW et al. Diabetes Technology & Therapeutics. 2022 (PMID: 36173235); Lynch J et al. Diabetes Technology & Therapeutics. 2022 (PMID: 36173238).