SourceMed · Shelf #5599 in the ask interface

Balloon valvuloplasty as a bridge to TAVI (observational only, split): symptoms and gradients improve and patients do reach TAVI — but the largest registry associates the bridge strategy with higher in-hospital mortality than direct TAVR

Shelf #5599 · Heart, vessels, blood pressure & clotting

SPLIT (benefit in bridge cohorts; mortality signal against the bridge strategy in registry data) — observational only: balloon valvuloplasty relieves symptoms and bridges selected patients to TAVI, but a 27,600-patient national registry associates bridging with higher in-hospital mortality than direct TAVR (5.6% vs 1.3%), and no randomised trial compares the strategies

Stamped: 2026-11-28.

Evidence published: 2016–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does balloon aortic valvuloplasty help as a bridge to TAVI?

Balance of the evidence

SPLIT — observational only, printed on the face. Balloon aortic valvuloplasty (BAV) reliably opens the valve for a time: in a 112-patient prospective cohort where 51.8% of procedures were bridges to TAVI, valve area rose from 0.59 to 0.82 cm2 and mean gradient fell from 58.0 to 40.5 mm Hg (Daniec 2017, PMID: 27514931), and in a 224-patient contemporary cohort 61% of BAV was bridging, half of patients improved by at least one NYHA class at 30 days, and 40% of the bridge group reached TAVI/AVR within 12 months — though 12-month mortality was still 26% in the bridge group (Dawson 2020, PMID: 32341170). A systematic review of 27 studies and 4,123 patients found BAV safer in the TAVI era (in-hospital mortality 4.6% vs 8.5% in the earlier era), with 23.4% of contemporary BAV done as a bridge to TAVR (Kumar 2016, PMID: 27466275). Against this, the largest record — a 27,600-patient Japanese national registry — found patients bridged with BAV before TAVR died in hospital more often than patients taken straight to TAVR (5.6% vs 1.3%), with bridging an independent correlate of death (Fujimoto 2024, PMID: 38977224); bridged patients are plausibly sicker and more often emergent, so confounding by indication likely explains part or all of that gap, but no randomised trial exists to settle it. SPLIT (symptom and haemodynamic benefit as a bridge in cohort data; a national-registry mortality signal against the bridge strategy versus direct TAVR) — observational only: BAV can carry selected unstable patients to TAVI, but the bridge strategy has never been shown to beat going straight to TAVI.

MeSH: Humans · Transcatheter Aortic Valve Replacement mortality trends · Male · Female · Hospital Mortality trends · Aged, 80 and over · Aortic Valve Stenosis surgery mortality · Retrospective Studies · Balloon Valvuloplasty mortality trends · Registries · Aged · Japan epidemiology

Cards (5)

Card 1 — Fujimoto 2024: in a 27,600-patient national registry, patients bridged with balloon valvuloplasty before TAVR died in hospital more often than patients taken straight to TAVR (5.6% vs 1.3%) — an observational association, not a randomised comparison

Study: Retrospective national registry analysis (Fujimoto 2024)

Population: 27,600 patients with aortic stenosis who underwent TAVR in Japan between October 2013 and March 2021, from a nationwide inpatient database: 27,387 direct TAVR and 213 who received balloon aortic valvuloplasty at least 1 day before TAVR as a bridge. Median age 85 years (interquartile range 82–88); 33.3% (9,188) were male.

Summary: Fujimoto 2024: in a 27,600-patient national registry, patients bridged with balloon valvuloplasty before TAVR died in hospital more often than patients taken straight to TAVR (5.6% vs 1.3%) — an observational association, not a randomised comparison

Result: Overall in-hospital mortality was 1.3% and fell over time, but the BAV bridge-to-TAVR group had significantly higher in-hospital mortality than the direct TAVR group (5.6% vs 1.3%; P < .0001), in both unplanned/emergent and planned admission settings. Factors associated with in-hospital mortality included age, body mass index, chronic renal disease, percutaneous coronary intervention, and BAV bridge to TAVR. The authors conclude that practical criteria for BAV bridge to TAVR should be proposed to improve outcomes.

Watch out: Confounding by indication is the central problem: patients are bridged precisely because they are unstable, emergent or temporarily unfit for TAVR, so a higher death rate in the bridged group is expected even if bridging itself helps them. Only 213 of 27,600 patients were bridged, and no adjustment in the record can fully remove that selection.

Source: Fujimoto T et al. Balloon aortic valvuloplasty bridge to transcatheter aortic valve replacement is associated with worse in-hospital mortality. International Journal of Cardiology. 2024. PMID: 38977224. Registry ID: none in the record. MeSH: Humans · Transcatheter Aortic Valve Replacement mortality trends · Male · Female · Hospital Mortality trends · Aged, 80 and over · Aortic Valve Stenosis surgery mortality · Retrospective Studies · Balloon Valvuloplasty mortality trends · Registries · Aged · Japan epidemiology

Card 2 — Dawson 2020: in a 224-patient contemporary cohort, 61% of balloon valvuloplasty was bridging; half improved a NYHA class by 30 days, 40% of the bridge group reached TAVI/AVR within a year, and 12-month mortality was 26% in the bridge group versus 50% for destination BAV

Study: Retrospective single-centre cohort (Dawson 2020)

Population: 224 patients (mean age 82.5 ± 8.3 years; 48% female) undergoing balloon aortic valvuloplasty at a single tertiary centre over 10 years. Indications were destination treatment in 39% and bridge to valve replacement in 61% — bridge to decision 29%, symptom relief while on the waitlist 27%, and temporary contraindications to TAVI/AVR 5%.

Summary: Dawson 2020: in a 224-patient contemporary cohort, 61% of balloon valvuloplasty was bridging; half improved a NYHA class by 30 days, 40% of the bridge group reached TAVI/AVR within a year, and 12-month mortality was 26% in the bridge group versus 50% for destination BAV

Result: Mean aortic pressure gradient fell by 38%. Procedural mortality was 0.5%, stroke 1.3% and major bleeding 0.9%. NYHA class improved by at least 1 in 50% of patients at 30 days. Twelve-month mortality was 36% overall — 26% in the bridging group and 50% in the destination group. Among the bridge-to-TAVI/AVR group, 40% proceeded to TAVI/AVR within 12 months of BAV. In multivariate analysis, active malignancy (OR 4.4, 95% CI 1.3 to 15.1), smoking history (OR 3.3, 95% CI 1.3 to 7.9), LVEF 30% or below (OR 3.2, 95% CI 1.3 to 7.6) and destination treatment (OR 2.2, 95% CI 1.0 to 4.9) were associated with 12-month mortality.

Watch out: There is no direct-TAVI or no-BAV comparator in this cohort: it shows bridging is feasible and symptoms improve, but the 60% of bridge patients who never reached valve replacement within a year — through death, refusal or new contraindications — is the sobering number.

Source: Dawson L et al. Utility of balloon aortic valvuloplasty in the transcatheter aortic valve implantation era. Open Heart. 2020. PMID: 32341170. Registry ID: none in the record. MeSH: Aortic Valve diagnostic imaging physiopathology surgery · Aortic Valve Stenosis diagnostic imaging mortality physiopathology surgery · Balloon Valvuloplasty adverse effects mortality · Databases, Factual · Female · Humans · Male · Retrospective Studies · Risk Factors · Time Factors · Transcatheter Aortic Valve Replacement adverse effects mortality · Treatment Outcome

Card 3 — Daniec 2017: in a prospective 112-patient cohort, balloon valvuloplasty done mainly as a bridge to TAVI (51.8%) raised valve area from 0.59 to 0.82 cm2 and cut mean gradient from 58.0 to 40.5 mm Hg, with 12-month mortality of 22.3%

Study: Prospective cohort (Daniec 2017)

Population: 112 patients with severe aortic stenosis undergoing 114 balloon aortic valvuloplasty procedures at two Polish interventional cardiology centres between October 2012 and July 2015, followed prospectively at 1, 6 and 12 months. Indications: bridge to TAVI 51.8%, bridge to surgical AVR 5.4%, before urgent noncardiac surgery 8.0%, symptom relief 33.0%, cardiogenic shock 1.8%.

Summary: Daniec 2017: in a prospective 112-patient cohort, balloon valvuloplasty done mainly as a bridge to TAVI (51.8%) raised valve area from 0.59 to 0.82 cm2 and cut mean gradient from 58.0 to 40.5 mm Hg, with 12-month mortality of 22.3%

Result: Periprocedural, in-hospital, 1-, 6- and 12-month mortality were 2.7%, 8.9%, 8.9%, 16.9% and 22.3% respectively; serious periprocedural adverse events occurred in 18.8% of patients. After the procedure, mean aortic valve area increased from 0.59 ± 0.18 to 0.82 ± 0.24 cm2, mean peak gradient fell from 94.0 ± 27.6 to 65.4 ± 20.0 mm Hg and mean gradient from 58.0 ± 17.8 to 40.5 ± 14.6 mm Hg (P < 0.05 for all). In patients with LVEF under 40%, ejection fraction improved significantly (median increase of 16%) at 1 and 6 months. The authors conclude the achieved effects can be sufficient in bridging patients for TAVI/AVR.

Watch out: A single-arm cohort of 112 very-high-risk patients: the haemodynamic gains are real but temporary by design, nearly one in five had a serious periprocedural adverse event, and nothing here compares bridging against proceeding directly to TAVI.

Source: Daniec M et al. Acute and long-term outcomes of percutaneous balloon aortic valvuloplasty for the treatment of severe aortic stenosis. Catheterization and Cardiovascular Interventions. 2017. PMID: 27514931. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Aortic Valve diagnostic imaging physiopathology · Aortic Valve Stenosis diagnostic imaging mortality physiopathology therapy · Balloon Valvuloplasty adverse effects mortality · Echocardiography · Female · Hemodynamics · Hospital Mortality · Humans · Male · Poland · Prospective Studies · Recovery of Function · Registries · Severity of Illness Index · Stroke Volume · Time Factors · Treatment Outcome · Ventricular Function, Left

Card 4 — Kumar 2016: across 27 studies and 4,123 patients, balloon valvuloplasty in the TAVI era was safer than in the early era (in-hospital mortality 4.6% vs 8.5%), and 23.4% of contemporary procedures were bridges to TAVR

Study: Systematic review (Kumar 2016)

Population: Systematic review of all published balloon aortic valvuloplasty studies from 1986 to June 2013 reporting at least 50 procedures: 27 studies representing 4,123 patients, comparing the early/pre-TAVR era with the contemporary/TAVR era (before versus after 2005).

Summary: Kumar 2016: across 27 studies and 4,123 patients, balloon valvuloplasty in the TAVI era was safer than in the early era (in-hospital mortality 4.6% vs 8.5%), and 23.4% of contemporary procedures were bridges to TAVR

Result: Significant and comparable improvement in transaortic gradients, aortic valve area and cardiac output followed BAV in both eras. In the contemporary era, BAV was performed as a bridge to TAVR in 23.4% of patients. Procedural death (1.5% vs 2.9%; P < .01), in-hospital mortality (4.6% vs 8.5%; P < .001) and major vascular complications (4.0% vs 10.2%; P < .001) were all significantly lower for BAV procedures in the contemporary/TAVR era than in the early era.

Watch out: Era comparisons mix better technique with different patient selection, and the review's outcomes are procedural — it cannot say whether patients bridged with BAV fare better than similar patients taken straight to TAVR, which is the comparison the registry card above attempts and the one no trial has made.

Source: Kumar A et al. Balloon Aortic Valvuloplasty in the Transcatheter Aortic Valve Replacement Era. The Journal of Invasive Cardiology. 2016. PMID: 27466275. Registry ID: none in the record. MeSH: Aortic Valve Stenosis diagnosis physiopathology surgery · Balloon Valvuloplasty adverse effects instrumentation methods · Comparative Effectiveness Research · Humans · Patient Selection · Severity of Illness Index · Transcatheter Aortic Valve Replacement adverse effects instrumentation methods

Card 5 — Synthesis: balloon valvuloplasty opens the valve, relieves symptoms and gets a substantial minority of unstable patients to TAVI — but the only large bridge-versus-direct comparison associates bridging with higher in-hospital mortality, and no randomised trial exists

Study: Synthesis

Population: The carded evidence: one national registry of 27,600 TAVR patients (213 bridged), one retrospective cohort of 224 BAV patients (61% bridging), one prospective cohort of 112 patients (51.8% bridged to TAVI) and one systematic review of 27 studies (4,123 patients). All observational; total carded participants exceed 30,000, so no small-N stamp labelling applies — the limitation is design, not size.

Summary: Synthesis: balloon valvuloplasty opens the valve, relieves symptoms and gets a substantial minority of unstable patients to TAVI — but the only large bridge-versus-direct comparison associates bridging with higher in-hospital mortality, and no randomised trial exists

Result: Haemodynamic benefit is consistent (valve area 0.59 to 0.82 cm2; mean gradient 58.0 to 40.5 mm Hg; Daniec 2017), symptom benefit is common (50% improved at least one NYHA class at 30 days; Dawson 2020), and procedural safety has improved in the TAVI era (in-hospital mortality 4.6% vs 8.5% in the early era; Kumar 2016). Yet only 40% of one bridge cohort reached TAVI/AVR within 12 months, and the 27,600-patient registry found higher in-hospital mortality with bridging than with direct TAVR (5.6% vs 1.3%; Fujimoto 2024) — an association confounding by indication may explain but cannot be wished away. SPLIT (benefit in bridge cohorts; mortality signal against the bridge strategy in registry data) — observational only.

Watch out: Every card on this shelf is observational. The registry's harm signal and the cohorts' benefit signal can both be true — bridging rescues patients who cannot wait, while marking out the sickest patients in the system — and only a randomised comparison of bridge versus direct TAVI could separate the two.

Source: Synthesis of Fujimoto T et al. International Journal of Cardiology. 2024 (PMID: 38977224); Dawson L et al. Open Heart. 2020 (PMID: 32341170); Daniec M et al. Catheterization and Cardiovascular Interventions. 2017 (PMID: 27514931); Kumar A et al. The Journal of Invasive Cardiology. 2016 (PMID: 27466275).