SourceMed · Shelf #5611 in the ask interface
For cardiac or unexplained syncope, the observational case is real (observational only): ~1.9% events/year and devices that fire — for clearly vasovagal syncope, the pooled evidence does not show added risk
Shelf #5611 · Heart, vessels, blood pressure & clotting
POSSIBLE (benefit) — observational only: Brugada patients with syncope had cardiac events at 1.9%/year (vs 0.5% asymptomatic), cardiac/unexplained syncope carried ~4.5-fold relative odds of major arrhythmic events while vasovagal syncope did not, and ICDs fired appropriately in 20.2% of recipients — at a 20.2% complication rate
Stamped: 2026-11-28.
Evidence published: 2010–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
Should patients with Brugada syndrome and syncope receive an ICD?
Balance of the evidence
POSSIBLE (benefit) — observational only, printed on the face; there is no randomised trial. The registries consistently place syncope patients at intermediate, real risk: cardiac events at 1.9% per year with syncope versus 0.5% per year asymptomatic and 7.7% per year after aborted sudden death (FINGER, PMID: 20100972), with syncope plus a spontaneous type 1 ECG predicting events (hazard ratio 4.20, relative; PRELUDE, PMID: 22192666). Pooled data split syncope by type — cardiac (odds ratio 4.48) and unexplained (4.71) syncope were associated with major arrhythmic events, vasovagal syncope was not (PMID: 37021016) — and in ICD recipients syncope with type 1 ECG predicted appropriate shocks (hazard ratio 4.96, relative), while 20.2% had other device complications (PMID: 29025556). POSSIBLE (benefit) — observational only: an ICD is most defensible for Brugada patients whose syncope is cardiac or unexplained, and least supported for clearly vasovagal syncope.
MeSH: Adult · Brugada Syndrome · Death · Electrocardiography · Female · Follow-Up Studies · Humans · Male · Middle Aged · Prognosis · Registries · Ventricular Fibrillation
Cards (5)
Card 1 — Probst 2010 (FINGER registry, 1,029 patients): cardiac events ran at 1.9% per year in Brugada patients with syncope — versus 0.5% per year in asymptomatic patients and 7.7% per year after aborted sudden death
Study: Prospective registry (Probst 2010, FINGER)
Population: 1,029 consecutive individuals (745 men, 72%; median age 45 years) with a type 1 Brugada ECG at baseline or after drug challenge, recruited at 11 tertiary centres in France, Italy, the Netherlands and Germany; presentation was aborted sudden cardiac death in 6%, otherwise unexplained syncope in 30%, and asymptomatic in 64%. Median follow-up was 31.9 months.
Summary: Probst 2010 (FINGER registry, 1,029 patients): cardiac events ran at 1.9% per year in Brugada patients with syncope — versus 0.5% per year in asymptomatic patients and 7.7% per year after aborted sudden death
Result: 51 cardiac events (5%) occurred — 44 patients received appropriate ICD shocks and 7 died suddenly. The cardiac event rate per year was 7.7% in patients with aborted sudden death, 1.9% in patients with syncope, and 0.5% in asymptomatic patients. Symptoms and a spontaneous type 1 ECG predicted arrhythmic events; gender, family history of sudden death, inducibility at electrophysiological study, and SCN5A mutation status did not.
Watch out: An appropriate ICD shock is counted as a cardiac event, so patients with devices generate 'events' that patients without devices cannot — the syncope group's rate is partly a measure of how often implanted devices fired, in a registry where implantation was itself driven by perceived risk.
Source: Probst V et al. Long-term prognosis of patients diagnosed with Brugada syndrome: Results from the FINGER Brugada Syndrome Registry. Circulation. 2010. PMID: 20100972. Registry ID: none in the record. MeSH: Adult · Brugada Syndrome · Death · Electrocardiography · Female · Follow-Up Studies · Humans · Male · Middle Aged · Prognosis · Registries · Ventricular Fibrillation
Card 2 — Priori 2012 (PRELUDE registry, 308 patients without prior arrest): syncope with a spontaneous type 1 ECG predicted arrhythmic events (hazard ratio 4.20, relative), while programmed stimulation inducibility did not — 9 of 14 events occurred in non-inducible patients
Study: Prospective registry (Priori 2012, PRELUDE)
Population: 308 consecutive individuals (247 men, 80%; median age 44 years) with a spontaneous or drug-induced type 1 Brugada ECG and no history of cardiac arrest, enrolled prospectively, undergoing programmed electrical stimulation at enrolment and followed every 6 months for a median of 34 months.
Summary: Priori 2012 (PRELUDE registry, 308 patients without prior arrest): syncope with a spontaneous type 1 ECG predicted arrhythmic events (hazard ratio 4.20, relative), while programmed stimulation inducibility did not — 9 of 14 events occurred in non-inducible patients
Result: 14 arrhythmic events (4.5%) occurred (13 appropriate ICD shocks and 1 cardiac arrest). Programmed stimulation induced ventricular tachyarrhythmias in 40% of patients, but inducibility was not a predictor of events at follow-up — 9 of the 14 events occurred in non-inducible patients. History of syncope and spontaneous type I ECG (hazard ratio 4.20 — a relative measure), ventricular refractory period under 200 ms (hazard ratio 3.91), and QRS fragmentation (hazard ratio 4.94) were significant predictors of arrhythmias. The authors conclude inducibility cannot identify high-risk patients, whereas syncope and a spontaneous type I ECG help identify candidates for a prophylactic ICD.
Watch out: Only 14 events drive every hazard ratio here, and the record presents syncope and spontaneous type 1 ECG together against a single hazard ratio of 4.20, so the independent contribution of syncope alone cannot be separated from this record.
Source: Priori SG et al. Risk stratification in Brugada syndrome: results of the PRELUDE (PRogrammed ELectrical stimUlation preDictive valuE) registry. Journal of the American College of Cardiology. 2012. PMID: 22192666. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Distribution · Aged · Brugada Syndrome · Cause of Death · Cohort Studies · Confidence Intervals · Defibrillators, Implantable · Electric Stimulation · Electrocardiography · Female · Humans · Incidence · Kaplan-Meier Estimate · Male · Middle Aged · Patient Selection · Registries · Risk Assessment · Severity of Illness Index · Sex Distribution · Statistics, Nonparametric · Survival Rate · Tachycardia, Ventricular · Ventricular Fibrillation · Young Adult
Card 3 — Rattanawong 2023 (meta-analysis, 4,355 patients): cardiac syncope (odds ratio 4.48) and unexplained syncope (odds ratio 4.71) were associated with major arrhythmic events — vasovagal syncope was not (odds ratio 2.90, not significant, very wide interval)
Study: Systematic review and meta-analysis (Rattanawong 2023)
Population: Systematic review and meta-analysis of 17 cohort studies (2005–2019) involving 4,355 patients with Brugada syndrome, classifying syncope as cardiac, unexplained, vasovagal, or undifferentiated, and examining its association with major arrhythmic events (MAE).
Summary: Rattanawong 2023 (meta-analysis, 4,355 patients): cardiac syncope (odds ratio 4.48) and unexplained syncope (odds ratio 4.71) were associated with major arrhythmic events — vasovagal syncope was not (odds ratio 2.90, not significant, very wide interval)
Result: Overall, syncope was associated with an increased risk of MAE (odds ratio 3.90, 95% CI 2.22–6.85; P < .001; I² = 76.0% — a relative measure). By type: cardiac syncope odds ratio 4.48 (95% CI 2.87–7.01; P < .001), unexplained syncope odds ratio 4.71 (95% CI 1.34–16.57; P = .016), vasovagal syncope odds ratio 2.90 (95% CI 0.09–98.45; P = .554, not significant), and undifferentiated syncope odds ratio 2.01 (95% CI 1.00–4.03; P = .050). The authors conclude cardiac and unexplained syncope carry similar increased MAE risk, while vasovagal syncope does not.
Watch out: Syncope classification was retrospective in the underlying cohorts and the vasovagal estimate is so imprecise (95% CI 0.09–98.45) that 'no association' means 'not demonstrated', not 'safe'; heterogeneity for the pooled syncope estimate was high (I² = 76%).
Source: Rattanawong P et al. Type of syncope and outcome in Brugada syndrome: A systematic review and meta-analysis. Journal of Arrhythmia. 2023. PMID: 37021016. Registry ID: none in the record. MeSH: not captured from the record
Card 4 — Hernandez-Ojeda 2017: among 104 Brugada patients with ICDs followed 9.3 years, 20.2% received appropriate shocks — type 1 ECG with syncope predicted them (hazard ratio 4.96, relative) — while 20.2% had other device complications and 8.7% inappropriate shocks
Study: Prospective ICD cohort (Hernandez-Ojeda 2017)
Population: 370 patients with Brugada syndrome in follow-up (age 43 ± 14 years; 74% male), of whom 104 (28.1%) received an ICD — 10 (9.6%) for secondary prevention and 94 (90.4%) for primary prevention — followed for 9.3 ± 5.1 years for shocks and complications.
Summary: Hernandez-Ojeda 2017: among 104 Brugada patients with ICDs followed 9.3 years, 20.2% received appropriate shocks — type 1 ECG with syncope predicted them (hazard ratio 4.96, relative) — while 20.2% had other device complications and 8.7% inappropriate shocks
Result: 21 patients (20.2%) experienced 81 appropriate shocks (incidence 2.2 per 100 person-years); the rate was higher in secondary prevention (P < .01), and 4 of 45 asymptomatic patients (8.9%) also received appropriate therapy. In multivariable analysis, type 1 electrocardiogram with syncope (hazard ratio 4.96, 95% CI 1.87 to 13.14; P < .01 — a relative measure) and secondary prevention indication (hazard ratio 6.85) predicted appropriate therapy. Nine patients (8.7%) experienced 37 inappropriate shocks, 21 patients (20.2%) had other ICD-related complications, and 3 patients (2.9%) died (1 electrical storm, 2 noncardiovascular). The authors conclude ICD therapy is effective in high-risk Brugada patients but carries a significant risk of device-related complications.
Watch out: There is no non-ICD comparison group, so this cohort can show that devices fire in syncope patients and harm a fifth of recipients — it cannot show how many deaths the devices prevented, and appropriate shocks overcount fatal events because some treated arrhythmias would have self-terminated.
Source: Hernandez-Ojeda J et al. Patients With Brugada Syndrome and Implanted Cardioverter-Defibrillators: Long-Term Follow-Up. Journal of the American College of Cardiology. 2017. PMID: 29025556. Registry ID: none in the record. MeSH: Adult · Brugada Syndrome · Cohort Studies · Defibrillators, Implantable · Electric Stimulation · Electrocardiography · Female · Follow-Up Studies · Humans · Male · Middle Aged · Prospective Studies · Registries · Time Factors
Card 5 — Synthesis: syncope in Brugada syndrome marks a roughly fourfold higher arrhythmic risk unless the syncope looks vasovagal — and ICDs in such patients fire appropriately in a fifth, at the cost of complications in a fifth (all observational)
Study: Synthesis
Population: The carded evidence: two prospective registries (FINGER, 1,029 patients; PRELUDE, 308 patients without prior arrest), a meta-analysis of 17 cohorts with 4,355 patients, and a 104-patient ICD cohort followed 9.3 years. Total carded participants exceed 5,000, so no small-N stamp labelling applies; every design is observational.
Summary: Synthesis: syncope in Brugada syndrome marks a roughly fourfold higher arrhythmic risk unless the syncope looks vasovagal — and ICDs in such patients fire appropriately in a fifth, at the cost of complications in a fifth (all observational)
Result: Event rates rose stepwise by presentation — 0.5% per year asymptomatic, 1.9% per year with syncope, 7.7% per year after aborted sudden death (FINGER). Syncope with a spontaneous type 1 ECG predicted events (hazard ratio 4.20, relative), and pooled data separate syncope types: cardiac (odds ratio 4.48) and unexplained (4.71) syncope were associated with major arrhythmic events, vasovagal syncope was not. In ICD recipients, syncope with type 1 ECG predicted appropriate shocks (hazard ratio 4.96, relative), while 20.2% suffered other device complications. POSSIBLE (benefit) — observational only: patients with Brugada syndrome and cardiac or unexplained syncope are the group in whom an ICD most plausibly prevents sudden death; the case is weakest for clearly vasovagal syncope.
Watch out: No randomised trial of ICDs in Brugada syndrome exists or is likely: the entire recommendation rests on risk prediction plus device firing rates, and misclassifying a vasovagal faint as arrhythmic syncope commits a low-risk patient to decades of device risk.
Source: Synthesis of Probst V et al. Circulation. 2010 (PMID: 20100972); Priori SG et al. Journal of the American College of Cardiology. 2012 (PMID: 22192666); Rattanawong P et al. Journal of Arrhythmia. 2023 (PMID: 37021016); Hernandez-Ojeda J et al. Journal of the American College of Cardiology. 2017 (PMID: 29025556).