SourceMed · Shelf #5761 in the ask interface

Hip protectors in nursing homes (SPLIT): pooled and cluster-trial evidence suggests fewer hip fractures, but the two individually randomised trials — including HIP PRO's within-person test — found the treatment made no difference

Shelf #5761 · Geriatrics, frailty & deprescribing

SPLIT (cluster and pooled evidence: benefit, pooled odds ratio 0.40 relative; individually randomised trials: the treatment made no difference — HIP PRO 3.1% protected vs 2.5% unprotected hips)

Stamped: 2026-11-28.

Evidence published: 2001–2007.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In older adults, does hip protector use reduce hip fractures in nursing home residents versus no hip protectors?

Balance of the evidence

SPLIT (cluster/pooled evidence: benefit; individually randomised evidence: the treatment made no difference) — hip protectors in nursing homes are a genuinely divided evidence base, and the divide follows study design. The pooled Bayesian estimate over 4 nursing-home trials is an odds ratio of 0.40 (relative; Sawka 2007) and the Hamburg cluster trial that raised wearing from 15% to 68% of fallers recorded 4.6% versus 8.1% hip fractures (relative risk 0.57, relative; P = 0.072; Meyer 2003). Against that, the two trials that randomised the pad itself found nothing: HIP PRO, comparing each resident's protected hip with their own unprotected hip in 1,042 residents with 73.8% adherence, recorded 3.1% versus 2.5% (the treatment made no difference; Kiel 2007), and Cameron 2001 recorded 8 versus 7 fractures (hazard ratio 1.46, relative). The library's umbrella hip-protector shelf, including the large Finnish cluster trial and the Cochrane review, is homed on live shelf #606; this shelf cards the nursing-home trials and their pooled analysis that frame the split. Adherence is the hinge throughout: no fracture in Cameron's trial happened while a protector was worn as directed, yet high supported adherence in HIP PRO still produced no benefit. SPLIT: whether hip protectors reduce hip fractures in nursing-home residents depends on which design you believe — programme-level provision may help; the pad's own measured effect in individually randomised trials is null.

MeSH: Aged, 80 and over · Female · Hip Fractures · Homes for the Aged · Humans · Male · Nursing Homes · Protective Clothing

Cards (5)

Card 1 — Kiel 2007 (HIP PRO): hip fractures occurred on 3.1% of protected hips versus 2.5% of unprotected hips in the same residents (the treatment made no difference), despite 73.8% adherence

Study: Randomised controlled trial, within-person design (Kiel 2007, HIP PRO)

Population: Multicentre randomised trial in 37 nursing homes in Boston, St Louis and Baltimore: 1,042 residents (mean age 85 years; 79% women) who consented and adhered during a 2-week run-in were randomised by facility to wear a one-sided hip protector on the left or right hip, so each resident's protected hip was compared with their own unprotected hip. Mean participation 7.8 months; facilities were visited 3 times per week to support adherence.

Summary: Kiel 2007 (HIP PRO): hip fractures occurred on 3.1% of protected hips versus 2.5% of unprotected hips in the same residents (the treatment made no difference), despite 73.8% adherence

Result: After 20 months of follow-up (676 person-years), the trial was terminated for lack of efficacy. The incidence of hip fracture on protected versus unprotected hips did not differ (3.1% [95% CI 1.8%–4.4%] versus 2.5% [95% CI 1.3%–3.7%]; P = .70) — the treatment made no difference. Among the 334 residents with over 80% adherence, fracture incidence also did not differ (5.3% versus 3.5%; P = .42). Overall adherence was 73.8%, and no participant was withdrawn because of adverse effects.

Watch out: The within-person design removes resident-level confounding and adherence was supported and measured — which is why this null carries weight — but a one-sided protector trial cannot detect any benefit that works by changing staff behaviour or fall patterns across a whole home.

Source: Kiel DP et al. Efficacy of a hip protector to prevent hip fracture in nursing home residents: the HIP PRO randomized controlled trial. JAMA. 2007. PMID: 17652295. Registry ID: NCT00058864. MeSH: Aged, 80 and over · Female · Hip Fractures · Homes for the Aged · Humans · Male · Nursing Homes · Protective Clothing

Card 2 — Meyer 2003: an education programme that raised protector use from 15% to 68% of fallers was followed by fewer hip fractures (4.6% versus 8.1%; relative risk 0.57, relative), but the difference was not significant (P = 0.072)

Study: Cluster randomised controlled trial (Meyer 2003)

Population: Cluster randomised trial in 49 nursing homes in Hamburg (25 intervention clusters, 24 control): 942 residents at high risk of falling (459 intervention, 483 control). The intervention was a single education session for nursing staff, who then educated residents, plus three free hip protectors per resident; control homes received brief information and two demonstration protectors per cluster. Mean follow-up 15 versus 14 months.

Summary: Meyer 2003: an education programme that raised protector use from 15% to 68% of fallers was followed by fewer hip fractures (4.6% versus 8.1%; relative risk 0.57, relative), but the difference was not significant (P = 0.072)

Result: There were 21 hip fractures in 21 residents (4.6%) in the intervention group and 42 fractures in 39 residents (8.1%) in the control group (relative risk 0.57, a relative measure; absolute risk difference −3.5% [95% CI −7.3% to 0.3%]; P = 0.072). After adjustment for cluster randomisation, the proportions of fallers wearing a protector were 68% versus 15% (mean difference 53% [95% CI 38% to 67%]; P = 0.0001). Other fractures were similar (39 versus 38). The authors conclude the programme increases protector use and may reduce hip fractures.

Watch out: The randomised unit was the home and the intervention was education plus free provision, so any benefit may belong to the programme (staff attention, fall awareness) rather than the pad itself; the fracture difference also misses conventional significance and 167 versus 207 residents died or moved away during follow-up.

Source: Meyer G et al. Effect on hip fractures of increased use of hip protectors in nursing homes: cluster randomised controlled trial. BMJ (Clinical research ed.). 2003. PMID: 12521969. Registry ID: none in the record. MeSH: Accidental Falls · Aged · Aged, 80 and over · Cluster Analysis · Female · Follow-Up Studies · Hip Fractures · Homes for the Aged · Humans · Male · Nursing Homes · Patient Education as Topic · Prognosis · Protective Devices · Risk Factors

Card 3 — Cameron 2001: 8 hip fractures with protectors versus 7 without (hazard ratio 1.46, relative) in 174 high-risk women — the treatment made no difference, in a trial too small to exclude a 50% relative reduction; no fracture occurred while a protector was worn as directed

Study: Randomised controlled trial (Cameron 2001)

Population: Individually randomised trial in 32 residential aged-care facilities in urban New South Wales, Australia (two-thirds nursing homes): 174 women aged 75 years or older (mean age 85) who had had two or more falls, or one fall requiring hospital admission, in the previous 3 months; 86 were allocated hip protectors with nurse encouragement and 88 to control. Participants had severe disability and major cognitive impairment on average (mean Barthel index 58).

Summary: Cameron 2001: 8 hip fractures with protectors versus 7 without (hazard ratio 1.46, relative) in 174 high-risk women — the treatment made no difference, in a trial too small to exclude a 50% relative reduction; no fracture occurred while a protector was worn as directed

Result: A mean of 4.6 falls per person occurred during follow-up. Eight hip fractures occurred in the intervention group and seven in the control group (hazard ratio 1.46 [95% CI 0.53–4.51], a relative measure) — the treatment made no difference. No hip fractures occurred when hip protectors were being worn as directed; adherence was about 57% overall and protectors were worn at the time of 54% of falls. Mortality was identical (28 deaths in each group). The authors note low statistical power: a reduction in hip-fracture risk of up to 50% (relative) may not have been detected.

Watch out: Fifteen fractures in total cannot settle efficacy either way; the 'no fracture while worn' observation is compatible with the pad working when worn and with chance, and adherence varied markedly between institutions (best about 80%).

Source: Cameron ID et al. Hip protectors in aged-care facilities: a randomized trial of use by individual higher-risk residents. Age and ageing. 2001. PMID: 11742776. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Australia · Female · Follow-Up Studies · Geriatric Assessment · Hip Fractures · Homes for the Aged · Humans · Nursing Homes · Patient Compliance · Protective Devices · Risk Factors

Card 4 — Sawka 2007: pooling the nursing-home trials the Bayesian way gave an odds ratio of 0.40 (95% credibility interval 0.25–0.61, relative) for hip fracture with protector allocation — a pooled benefit the individually randomised trials do not show

Study: Bayesian meta-analysis of randomised trials (Sawka 2007)

Population: Bayesian random-effects meta-analysis designed to pool cluster-randomised with individually randomised trials of hip protectors in nursing homes: 4 trials of 1,922 nursing-home residents, including three cluster-randomised trials.

Summary: Sawka 2007: pooling the nursing-home trials the Bayesian way gave an odds ratio of 0.40 (95% credibility interval 0.25–0.61, relative) for hip fracture with protector allocation — a pooled benefit the individually randomised trials do not show

Result: The pooled mean odds ratio of an elderly nursing-home resident sustaining one or more hip fractures with hip-protector allocation was 0.40 (95% credibility interval 0.25–0.61), a relative measure. The model was robust in sensitivity analyses assuming alternative intracluster correlation values. The authors themselves caution that methodological limitations of the included trials and a possible herd effect in the cluster trials may have influenced the results.

Watch out: The pooled estimate leans heavily on cluster trials — including the large Finnish cluster trial homed on live shelf #606 — in which whole homes changed behaviour together; when the pad itself is randomised within or between individuals, the benefit disappears (Kiel 2007; Cameron 2001).

Source: Sawka AM et al. Hip protectors decrease hip fracture risk in elderly nursing home residents: a Bayesian meta-analysis. Journal of clinical epidemiology. 2007. PMID: 17346606. Registry ID: none in the record. MeSH: Aged · Bayes Theorem · Cluster Analysis · Hip Fractures · Homes for the Aged · Humans · Nursing Homes · Patient Compliance · Protective Devices · Randomized Controlled Trials as Topic · Risk Factors · Software

Card 5 — Synthesis: the evidence genuinely divides by design — pooled and cluster-trial evidence says benefit (odds ratio 0.40, relative), while the two individually randomised trials, including the largest and best-adhered, found the treatment made no difference

Study: Synthesis

Population: The carded evidence: two individually randomised nursing-home trials (1,042 and 174 residents), one cluster-randomised education-and-provision trial (942 residents), and a Bayesian meta-analysis of 4 trials (1,922 residents) that overlaps the primary trials, so totals are not summed. No small-N labelling applies to the shelf as a whole; the smallest trial's N (174) and its 15 fractures are printed on its card face.

Summary: Synthesis: the evidence genuinely divides by design — pooled and cluster-trial evidence says benefit (odds ratio 0.40, relative), while the two individually randomised trials, including the largest and best-adhered, found the treatment made no difference

Result: Hip fracture incidence was 3.1% on protected versus 2.5% on unprotected hips in HIP PRO (the treatment made no difference; Kiel 2007) and 8 versus 7 fractures in Cameron 2001 (hazard ratio 1.46, relative). The cluster trial that raised wearing from 15% to 68% of fallers recorded 4.6% versus 8.1% fractures (relative risk 0.57, relative; P = 0.072; Meyer 2003), and pooling gave an odds ratio of 0.40 (Sawka 2007). Adherence is the hinge in every report: no fracture in Cameron's trial occurred while a protector was worn as directed, yet even 73.8% supported adherence in HIP PRO produced no benefit. SPLIT (cluster/pooled evidence: benefit; individually randomised evidence: the treatment made no difference).

Watch out: A shelf that quoted only the pooled odds ratio would mislead: the split tracks study design, not chance alone, and the most rigorous design for the pad's own effect — randomising hips within the same resident — is the one that found nothing.

Source: Synthesis of Kiel DP et al. JAMA. 2007 (PMID: 17652295); Meyer G et al. BMJ (Clinical research ed.). 2003 (PMID: 12521969); Cameron ID et al. Age and ageing. 2001 (PMID: 11742776); Sawka AM et al. Journal of clinical epidemiology. 2007 (PMID: 17346606).