SourceMed · Shelf #5943 in the ask interface

Repositioning plus mattress versus standard care (completion of #796): 4-hourly turning on viscoelastic foam cut grade II+ ulcers to 3.0% in nursing-home patients — one trial, reviews unsettled

Shelf #5943 · Geriatrics, frailty & deprescribing

POSSIBLE (benefit) — regular repositioning on a pressure-redistributing mattress prevents grade II-or-worse pressure injuries in immobile older adults: 3.0% versus 14.3–24.1% against other regimens including standard care in one 838-patient nursing-home trial; Cochrane reviews leave the best frequency and surface uncertain

Stamped: 2026-11-28.

Evidence published: 2005–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Do regular repositioning and pressure-redistributing mattresses prevent pressure injuries in immobile older adults?

Balance of the evidence

Completion of live shelf #796, which covers the slices of frequency (2- versus 4-hourly turning, TURN) and of mattress-versus-mattress comparison (PRESSURE 2); this shelf covers the slice #796 does not: whether repositioning plus a pressure-redistributing mattress prevents pressure injuries at all, against standard care, in immobile older adults. Only one trial answers that directly (Defloor 2005, PMID: 15582638): in 838 nursing-home patients, turning every 4 hours on a viscoelastic foam mattress produced grade II-or-worse ulcers in 3.0%, versus 14.3–24.1% across the other regimens including standard preventive care — while early skin redness (non-blanchable erythema) did not differ (34.8–38.1%). The Cochrane repositioning review (Gillespie 2020, PMID: 32484259) found the frequency evidence very low certainty (2- versus 4-hourly relative risk 1.06), and the Cochrane foam review (Shi 2021, PMID: 34097765) found foam may be worse than air surfaces — neither review contains a trial of the combined package versus no prevention. So the package is supported by one large trial against standard care; the optimal frequency and surface remain unsettled. POSSIBLE (benefit): regular repositioning combined with a pressure-redistributing mattress prevents grade II-or-worse pressure injuries in immobile older adults, on single-trial evidence against standard care.

MeSH: Aged · Aged, 80 and over · Beds · Equipment Design · Europe/epidemiology · Female · Homes for the Aged · Humans · Incidence · Logistic Models · Male · Multivariate Analysis · Nursing Homes · Posture · Pressure Ulcer/epidemiology/prevention & control · Statistics, Nonparametric

Cards (4)

Card 1 — Defloor 2005: turning every 4 hours on a viscoelastic foam mattress gave grade II+ pressure ulcers in 3.0% versus 14.3–24.1% in the other regimens (including standard care) — 838 nursing-home patients

Study: Multicentre randomised controlled trial (Defloor 2005)

Population: 838 geriatric nursing-home patients in a multicentre randomised trial of four preventive regimens over 28 days: turning every 2 hours on a standard institutional mattress (n = 65), every 3 hours on a standard mattress (n = 65), every 4 hours on a viscoelastic foam mattress (n = 67), or every 6 hours on a viscoelastic foam mattress (n = 65); the remaining 576 patients received standard preventive care.

Summary: Defloor 2005: turning every 4 hours on a viscoelastic foam mattress gave grade II+ pressure ulcers in 3.0% versus 14.3–24.1% in the other regimens (including standard care) — 838 nursing-home patients

Result: The incidence of grade II and higher pressure ulcers in the 4-hourly turning on viscoelastic foam group was 3.0%, compared with incidence figures in the other groups varying between 14.3% and 24.1%. The incidence of non-blanchable erythema (grade I) was 34.8–38.1% and did not differ between groups (the treatment made no difference to early redness). The authors conclude that turning every 4 hours on a viscoelastic mattress significantly reduced pressure ulcer lesions and makes turning feasible in effort and cost.

Watch out: The experimental turning groups were small (65–67 patients each) against a much larger standard-care group, allocation and blinding are limited in a turning trial, and the winning regimen combines two changes at once (mattress plus schedule) — the trial cannot say which component, or whether either alone, did the work.

Source: Defloor T et al. The effect of various combinations of turning and pressure reducing devices on the incidence of pressure ulcers.. International journal of nursing studies. 2005. PMID: 15582638. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Beds · Equipment Design · Europe/epidemiology · Female · Homes for the Aged · Humans · Incidence · Logistic Models · Male · Multivariate Analysis · Nursing Homes · Posture · Pressure Ulcer/epidemiology/prevention & control · Statistics, Nonparametric

Card 2 — Gillespie 2020 (Cochrane repositioning): 2-hourly versus 4-hourly repositioning relative risk 1.06 — it is uncertain whether frequency changes incidence at all; all eight trials at high risk of bias

Study: Systematic review and meta-analysis of randomised trials (Cochrane; Gillespie 2020)

Population: Cochrane systematic review of repositioning regimens for pressure injury prevention in adults in any setting: eight trials with 3,941 participants from acute and long-term care, with short follow-up (24 hours to 21 days). Six studies reported the proportion developing a pressure injury of any stage.

Summary: Gillespie 2020 (Cochrane repositioning): 2-hourly versus 4-hourly repositioning relative risk 1.06 — it is uncertain whether frequency changes incidence at all; all eight trials at high risk of bias

Result: Pooling three trials (1,074 participants) comparing 2-hourly with 4-hourly repositioning (used with various support surfaces) gave a relative risk of 1.06 (95% CI 0.80 to 1.41) — the reviewers conclude it is uncertain whether 2-hourly repositioning increases or decreases pressure injury incidence compared with 4-hourly, rating the certainty of evidence very low (downgraded twice for risk of bias and once for imprecision). All included studies were at high risk of bias. The record reports no pooled comparison of any repositioning versus no repositioning.

Watch out: This review compares schedules against each other, never against no repositioning — it cannot answer this shelf's prevention-versus-none question, and its very-low-certainty verdict is about frequency, not about whether repositioning works at all.

Source: Gillespie BM et al. Repositioning for pressure injury prevention in adults.. The Cochrane database of systematic reviews. 2020. PMID: 32484259. Registry ID: none in the record. MeSH: Aged · Beds · Cost-Benefit Analysis · Humans · Middle Aged · Patient Positioning/economics/methods · Pressure Ulcer/prevention & control · Randomized Controlled Trials as Topic · Time Factors

Card 3 — Shi 2021 (Cochrane foam surfaces): foam may increase ulcer risk compared with air surfaces (relative risk 1.59 versus alternating-pressure air; 2.40 versus reactive air) — foam is the floor, not the ceiling, of mattress prevention

Study: Systematic review and meta-analysis of randomised trials (Cochrane; Shi 2021)

Population: Cochrane systematic review of foam beds, mattresses and overlays for pressure ulcer prevention: 29 studies with 9,566 participants, mainly from acute care settings, median study size 101 participants and participant ages averaging 47.0 to 85.3 years (median 76.0). Seventeen of 29 studies (58.6%) were at high overall risk of bias.

Summary: Shi 2021 (Cochrane foam surfaces): foam may increase ulcer risk compared with air surfaces (relative risk 1.59 versus alternating-pressure air; 2.40 versus reactive air) — foam is the floor, not the ceiling, of mattress prevention

Result: Low-certainty evidence suggests foam surfaces may increase the risk of developing new pressure ulcers compared with alternating pressure (active) air surfaces (relative risk 1.59, 95% CI 0.86 to 2.95; 4 studies, 2,247 participants) and compared with reactive air surfaces (relative risk 2.40, 95% CI 1.04 to 5.54; 4 studies, 229 participants). Comparisons against unspecified surfaces were recorded but not analysed, so the review gives no pooled estimate for foam versus a standard institutional mattress.

Watch out: Mostly acute-care, mostly small and bias-prone trials: the finding that air surfaces beat foam does not contradict Defloor (whose foam mattress was compared with standard care and less-redistributing regimens), but it warns against reading 'pressure-redistributing mattress' as a single uniform intervention.

Source: Shi C et al. Foam surfaces for preventing pressure ulcers.. The Cochrane database of systematic reviews. 2021. PMID: 34097765. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Air · Bedding and Linens · Beds · Bias · Female · Gels · Humans · Incidence · Male · Middle Aged · Pressure Ulcer/epidemiology/prevention & control · Randomized Controlled Trials as Topic · Viscoelastic Substances

Card 4 — Synthesis: one large nursing-home trial supports the combined package against standard care (3.0% versus 14.3–24.1% grade II+ ulcers); the reviews settle neither frequency nor surface — POSSIBLE

Study: Synthesis

Population: The carded evidence: one multicentre randomised trial in 838 nursing-home patients (the only card comparing a repositioning-plus-mattress package with standard preventive care) and two Cochrane reviews totalling 3,941 (repositioning) and 9,566 (foam surfaces) participants across schedule- and surface-comparison trials. Total carded participants exceed 30, so no small-N stamp labelling applies.

Summary: Synthesis: one large nursing-home trial supports the combined package against standard care (3.0% versus 14.3–24.1% grade II+ ulcers); the reviews settle neither frequency nor surface — POSSIBLE

Result: Grade II+ ulcers: 3.0% with 4-hourly turning on viscoelastic foam versus 14.3–24.1% in other regimens including standard care (Defloor 2005); grade I redness did not differ. Repositioning frequency: relative risk 1.06 (95% CI 0.80 to 1.41) for 2- versus 4-hourly, very low certainty (Gillespie 2020). Surface: foam worse than air surfaces on low-certainty evidence (Shi 2021). POSSIBLE (benefit) for the combined package versus standard care.

Watch out: No trial has randomised immobile older adults to repositioning-plus-mattress versus truly no prevention, for ethical reasons; 'standard preventive care' in Defloor is the honest comparator, and the effect rests on that one trial.

Source: Synthesis of Defloor T et al. International journal of nursing studies. 2005 (PMID: 15582638); Gillespie BM et al. The Cochrane database of systematic reviews. 2020 (PMID: 32484259); Shi C et al. The Cochrane database of systematic reviews. 2021 (PMID: 34097765).