SourceMed · Shelf #6017 in the ask interface

Catheter ablation and mortality in ischaemic ventricular tachycardia (completion of live #713): ablation cuts shocks and ICD therapy, but no randomised report shows fewer deaths

Shelf #6017 · Heart, vessels, blood pressure & clotting

POSSIBLE — catheter ablation has not been shown to reduce mortality in ischaemic ventricular tachycardia: every randomised comparison is null for death (the treatment made no difference), though all were powered for arrhythmia outcomes rather than survival

Stamped: 2026-11-28.

Evidence published: 2007–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does catheter ablation reduce mortality in ventricular tachycardia with ischemic cardiomyopathy?

Balance of the evidence

POSSIBLE — printed on the face. This pack is a completion: live shelf #713 already answers ablation versus escalating antiarrhythmic drugs in ICD patients with recurrent VT (VANISH, PMID 27149033, and PARTITA, PMID 35369700 — both homed there and not re-carded here), where death sat inside composite endpoints. This shelf asks the narrower question those composites leave open: does ablation itself reduce mortality? Five free randomised reports answer it, and none shows a mortality reduction. SMASH-VT (128 patients) found deaths of 9% with ablation versus 17% without (P=0.29 — the treatment made no difference) while ICD therapy fell sharply (hazard ratio 0.35). VTACH (110 patients) recorded five deaths against four. BERLIN VT, testing preventive against deferred ablation, found more deaths in the preventive arm (7.9% vs 2.4%, P=0.18) and was stopped early for futility. Pooling the three prophylactic-ablation trials (346 patients), the all-cause mortality odds ratio was 0.77 (95% CI 0.41–1.46) — no significant difference. The largest and newest trial, VANISH 2 (416 patients), lowered a composite that includes death (50.7% vs 60.6%; hazard ratio 0.75), but its record does not report mortality separately, so it cannot carry a survival claim. POSSIBLE: ablation's proven benefit is fewer shocks and less ICD therapy (homed on #713); a mortality benefit remains unproven, and every trial here was powered for arrhythmia endpoints, not death, so a modest survival effect is not excluded.

MeSH: Aged · Catheter Ablation · Death, Sudden, Cardiac · Defibrillators, Implantable · Electric Countershock · Female · Follow-Up Studies · Humans · Kaplan-Meier Estimate · Male · Middle Aged · Multivariate Analysis · Myocardial Infarction · Prospective Studies · Tachycardia, Ventricular · Ventricular Fibrillation

Cards (6)

Card 1 — SMASH-VT 2007: prophylactic ablation cut ICD therapy (hazard ratio 0.35) but mortality was 9% vs 17% — the treatment made no difference to survival (P=0.29)

Study: Randomised controlled trial (SMASH-VT, Reddy 2007)

Population: 128 patients with previous myocardial infarction receiving an ICD for spontaneous ventricular tachycardia or fibrillation, randomised to ICD implantation alone (n = 64) or ICD plus substrate-based catheter ablation (n = 64); no antiarrhythmic drugs were used.

Summary: SMASH-VT 2007: prophylactic ablation cut ICD therapy (hazard ratio 0.35) but mortality was 9% vs 17% — the treatment made no difference to survival (P=0.29)

Result: Over a mean follow-up of 22.5 months, appropriate ICD therapy occurred in 12% of the ablation group versus 33% of controls (hazard ratio 0.35, 95% CI 0.15–0.78; P=0.007) and shocks in 9% versus 31% (P=0.003). Mortality, this shelf's outcome, was 9% in the ablation group versus 17% in the control group (P=0.29) — not significantly different; the treatment made no difference to survival. No patient died within 30 days of ablation.

Watch out: With 128 patients and few deaths in total, SMASH-VT had almost no power for mortality, and its point estimate favours ablation — so this card shows 'not demonstrated', not 'disproven'; the same caution applies to every card on this shelf.

Source: Reddy VY et al. Prophylactic catheter ablation for the prevention of defibrillator therapy. The New England journal of medicine. 2007. PMID: 18160685. Registry ID: ISRCTN62488166. MeSH: Aged · Catheter Ablation · Death, Sudden, Cardiac · Defibrillators, Implantable · Electric Countershock · Female · Follow-Up Studies · Humans · Kaplan-Meier Estimate · Male · Middle Aged · Multivariate Analysis · Myocardial Infarction · Prospective Studies · Tachycardia, Ventricular · Ventricular Fibrillation

Card 2 — VTACH 2010: ablation before ICD implantation delayed VT recurrence, but nine patients died — five in the ablation group, four in the control group

Study: Randomised controlled trial (VTACH, Kuck 2010)

Population: 110 patients aged 18–80 with stable ventricular tachycardia, previous myocardial infarction and left-ventricular ejection fraction ≤50%, randomised to catheter ablation plus ICD (n = 54) or ICD alone (n = 56) in 16 European centres; 107 were analysed by intention to treat.

Summary: VTACH 2010: ablation before ICD implantation delayed VT recurrence, but nine patients died — five in the ablation group, four in the control group

Result: Time to recurrence of VT or ventricular fibrillation was longer with ablation (median 18.6 vs 5.9 months; hazard ratio 0.61, 95% CI 0.37–0.99; p=0.045). Nine patients died during the study — five in the ablation group and four in the control group — so the treatment made no difference to mortality. No death occurred within 30 days of ablation, and ablation-related complications occurred in two patients.

Watch out: VTACH was open-label and powered for time to VT recurrence; its nine deaths cannot settle a survival question either way.

Source: Kuck KH et al. Catheter ablation of stable ventricular tachycardia before defibrillator implantation in patients with coronary heart disease (VTACH): a multicentre randomised controlled trial. Lancet (London, England). 2010. PMID: 20109864. Registry ID: NCT00919373. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Catheter Ablation · Coronary Disease · Defibrillators, Implantable · Female · Follow-Up Studies · Humans · Male · Middle Aged · Tachycardia, Ventricular · Treatment Outcome

Card 3 — BERLIN VT 2020: ablating preventively rather than after three shocks did not reduce death or hospitalisation (hazard ratio 1.09) — deaths ran 7.9% vs 2.4% the other way, and the trial stopped early for futility

Study: Randomised controlled trial (BERLIN VT, Willems 2020)

Population: 159 patients with stable ischaemic cardiomyopathy, left-ventricular ejection fraction 30–50% and documented VT, randomised at 26 centres to preventive VT ablation before ICD implantation (n = 76) or a deferred strategy of ablation after three ICD shocks (n = 83).

Summary: BERLIN VT 2020: ablating preventively rather than after three shocks did not reduce death or hospitalisation (hazard ratio 1.09) — deaths ran 7.9% vs 2.4% the other way, and the trial stopped early for futility

Result: Over a mean follow-up of 396 days, the primary composite of all-cause death or unplanned hospitalisation for symptomatic ventricular arrhythmia or worsening heart failure occurred in 32.9% of the preventive group and 27.7% of the deferred group (hazard ratio 1.09, 95% CI 0.62–1.92; P=0.77) — the treatment made no difference. Six patients died in the preventive group versus two in the deferred group (7.9% vs 2.4%; P=0.18), and heart-failure admissions also ran higher with preventive ablation (10.4% vs 2.3%; P=0.062), although sustained ventricular tachyarrhythmia and appropriate ICD therapy were numerically less frequent. The trial was terminated early for futility on prespecified interim criteria.

Watch out: BERLIN VT compares two ablation timings — everyone was meant to be ablated eventually — so it tests strategy, not ablation versus no ablation; its mortality numbers are small and early termination widens uncertainty in both directions.

Source: Willems S et al. Preventive or Deferred Ablation of Ventricular Tachycardia in Patients With Ischemic Cardiomyopathy and Implantable Defibrillator (BERLIN VT): A Multicenter Randomized Trial. Circulation. 2020. PMID: 32000514. Registry ID: NCT02501005. MeSH: Aged · Cardiomyopathies · Catheter Ablation · Defibrillators, Implantable · Female · Humans · Male · Prospective Studies · Tachycardia, Ventricular

Card 4 — Atti 2018: pooling the three prophylactic-ablation trials (346 patients), ICD therapy fell (odds ratio 0.49) but all-cause mortality did not (odds ratio 0.77, 95% CI 0.41–1.46)

Study: Systematic review and meta-analysis of 3 randomised trials (Atti 2018)

Population: Systematic review and meta-analysis of the three randomised trials to November 2017 comparing prophylactic catheter ablation plus ICD against ICD alone in ischaemic cardiomyopathy (346 patients in total, including SMASH-VT and VTACH, carded above).

Summary: Atti 2018: pooling the three prophylactic-ablation trials (346 patients), ICD therapy fell (odds ratio 0.49) but all-cause mortality did not (odds ratio 0.77, 95% CI 0.41–1.46)

Result: Prophylactic ablation was associated with fewer ICD therapies (odds ratio 0.49, 95% CI 0.28–0.87) and fewer ICD shocks (odds ratio 0.38, 95% CI 0.22–0.64). There was no significant difference in all-cause mortality (odds ratio 0.77, 95% CI 0.41–1.46; p=0.42), cardiovascular mortality (odds ratio 0.49, 95% CI 0.16–1.50) or major adverse events (odds ratio 1.45, 95% CI 0.52–4.01) — on mortality, the treatment made no difference.

Watch out: The pooled confidence interval for mortality (0.41–1.46) is wide: these data exclude neither a worthwhile survival benefit nor harm, which is why this shelf's stamp stops at POSSIBLE rather than claiming a proven null.

Source: Atti V et al. Prophylactic catheter ablation of ventricular tachycardia in ischemic cardiomyopathy: a systematic review and meta-analysis of randomized controlled trials. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2018. PMID: 29680972. Registry ID: none in the record. MeSH: Aged · Cardiomyopathies · Catheter Ablation · Defibrillators, Implantable · Electrocardiography · Female · Humans · Male · Middle Aged · Myocardial Ischemia · Primary Prevention · Prognosis · Randomized Controlled Trials as Topic · Risk Assessment · Tachycardia, Ventricular · Treatment Outcome

Card 5 — VANISH 2 2025: first-line ablation beat antiarrhythmic drugs on a composite that includes death (50.7% vs 60.6%; hazard ratio 0.75) — but the record does not report mortality on its own

Study: Randomised controlled trial (VANISH 2, Sapp 2025)

Population: 416 patients with previous myocardial infarction, an ICD and clinically significant ventricular tachycardia (VT storm, appropriate ICD shock or antitachycardia pacing, or sustained VT terminated by emergency treatment), randomised internationally to catheter ablation within 14 days (n = 203) or antiarrhythmic drug therapy with sotalol or amiodarone (n = 213); median follow-up 4.3 years.

Summary: VANISH 2 2025: first-line ablation beat antiarrhythmic drugs on a composite that includes death (50.7% vs 60.6%; hazard ratio 0.75) — but the record does not report mortality on its own

Result: A primary end-point event — death from any cause, or, more than 14 days after randomisation, VT storm, appropriate ICD shock, or sustained VT treated by medical intervention — occurred in 50.7% of the ablation group versus 60.6% of the drug group (hazard ratio 0.75, 95% CI 0.58–0.97; P=0.03), a relative measure. Death is inside that composite, but the published record does not separate deaths by arm, so no mortality-specific claim can be taken from this trial. Within 30 days, death occurred in 2 ablation patients (1.0%) as a procedural-period adverse event, and 1 drug-group death (0.5%) was attributed to pulmonary toxicity of treatment.

Watch out: A favourable composite that mixes death with shocks and VT episodes cannot be read as a survival benefit; VANISH (2016), the sister trial in drug-refractory VT, is homed on live shelf #713 and likewise found no significant mortality difference on its own.

Source: Sapp JL et al. Catheter Ablation or Antiarrhythmic Drugs for Ventricular Tachycardia. The New England journal of medicine. 2025. PMID: 39555820. Registry ID: NCT02830360. MeSH: Aged · Female · Humans · Male · Middle Aged · Amiodarone · Anti-Arrhythmia Agents · Catheter Ablation · Defibrillators, Implantable · Follow-Up Studies · Kaplan-Meier Estimate · Myocardial Infarction · Sotalol · Tachycardia, Ventricular · Treatment Outcome

Card 6 — Synthesis: across five randomised reports, ablation reduces shocks and ICD therapy but no comparison shows fewer deaths

Study: Synthesis

Population: The carded evidence: four randomised trials (SMASH-VT 128, VTACH 110, BERLIN VT 159, VANISH 2 416 patients) and one meta-analysis of the three prophylactic-ablation trials (346 patients). Total carded participants exceed 800, so no small-N stamp labelling applies.

Summary: Synthesis: across five randomised reports, ablation reduces shocks and ICD therapy but no comparison shows fewer deaths

Result: On mortality itself, every randomised comparison is null: SMASH-VT 9% vs 17% (P=0.29), VTACH five deaths versus four, BERLIN VT 7.9% vs 2.4% (P=0.18, favouring deferral), pooled all-cause mortality odds ratio 0.77 (95% CI 0.41–1.46), and VANISH 2 reporting no mortality-only figure. What ablation demonstrably reduces is arrhythmia burden — ICD therapy, shocks and VT recurrence — which is the benefit homed on live shelf #713. POSSIBLE: no mortality reduction has been shown for catheter ablation in ischaemic ventricular tachycardia; the trials were powered for arrhythmia outcomes, so a modest survival effect remains possible but unproven.

Watch out: Do not quote VANISH 2's composite hazard ratio (0.75) as a mortality result — death is only one component, and the trial's record gives no deaths-by-arm count.

Source: Synthesis of Reddy VY et al. The New England journal of medicine. 2007 (PMID: 18160685); Kuck KH et al. Lancet (London, England). 2010 (PMID: 20109864); Willems S et al. Circulation. 2020 (PMID: 32000514); Atti V et al. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2018 (PMID: 29680972); Sapp JL et al. The New England journal of medicine. 2025 (PMID: 39555820).