TAVI versus surgery at 10 years in intermediate-risk aortic stenosis (completion of live #3360): the answer splits by valve generation and access route

Shelf #6028 · Heart, vessels, blood pressure & clotting

SPLIT (device generation and access route) — at 10 years in intermediate-risk patients, second-generation SAPIEN XT TAVI had higher mortality than surgery (86.1% vs 82.8%; HR 1.13 relative) and more reintervention (6.3% vs 1.6%), driven by transthoracic access, while third-generation SAPIEN 3 TAVI matched surgery on mortality (HR 1.01 relative) and reintervention (2.0% vs 1.9%); in lower-risk NOTION, severe structural valve deterioration was less frequent after TAVI (1.5% vs 10.0%)

Stamped: 2026-11-28.

Evidence published: 2024–2026.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Is TAVI as durable as surgery at 10 years in intermediate-risk patients?

Balance of the evidence

SPLIT (device generation and access route) — the 10-year answer live shelf #3360 could not give from its 1-year DEDICATE result. In the only fully randomised 10-year intermediate-risk comparison, PARTNER 2A (Thourani 2026; 1,910 patients who received a valve, mean STS score 5.8%), TAVI with the second-generation SAPIEN XT valve was associated with higher 10-year mortality than surgery (86.1% versus 82.8%; HR 1.13 relative; P=0.02) and four times the reintervention rate (6.3% versus 1.6%) — but the mortality gap was concentrated in the transthoracic (transapical/transaortic) access cohort (93.2% versus 85.1%), while transfemoral patients fared similarly (83.9% versus 82.1%). With the third-generation SAPIEN 3 valve, a propensity-matched comparison against the same surgical cohort found mortality (83.4% versus 82.3%; HR 1.01 relative) and reintervention (2.0% versus 1.9%) essentially identical at 10 years (Nazif 2026). On structural durability itself, the lower-risk NOTION trial found severe structural valve deterioration LESS often after TAVI than after surgical bioprostheses at 10 years (1.5% versus 10.0%; HR 0.2 relative), with bioprosthetic valve failure similar (9.7% versus 13.8%). SPLIT: durability at 10 years depends on which valve and which route — the early-generation transthoracic experience was worse than surgery; transfemoral and newer-generation results match it.

MeSH: Humans · Aortic Valve Stenosis/surgery,mortality,diagnostic imaging,diagnosis · Female · Transcatheter Aortic Valve Replacement/methods,mortality · Treatment Outcome · Male · Aged, 80 and over · Follow-Up Studies · Echocardiography · Aged · Time Factors · Heart Valve Prosthesis Implantation/methods · Aortic Valve/surgery,diagnostic imaging · Risk Factors

Cards (4)

Card 1 — PARTNER 2A at 10 years (Thourani 2026): mortality 86.1% after SAPIEN XT TAVI versus 82.8% after surgery (HR 1.13, P=0.02), reintervention 6.3% versus 1.6% — with the mortality gap confined to transthoracic access

Study: Randomised controlled trial, 10-year follow-up (PARTNER 2A, Thourani 2026)

Population: 1,910 intermediate-risk patients with severe symptomatic aortic stenosis who received a valve in the PARTNER 2A randomised trial (57 centres, 2011–2013): 974 TAVI with the balloon-expandable SAPIEN XT system (Edwards Lifesciences; 76.9% transfemoral, the rest transapical/transaortic) and 936 surgical replacement; mean age 81.6 years, 45.4% women, mean STS score 5.8%; vital status at 10 years available for about 90% of each group after reconsent and vital-status sweeps.

Summary: PARTNER 2A at 10 years (Thourani 2026): mortality 86.1% after SAPIEN XT TAVI versus 82.8% after surgery (HR 1.13, P=0.02), reintervention 6.3% versus 1.6% — with the mortality gap confined to transthoracic access

Result: All-cause mortality at 10 years was 86.1% after TAVI and 82.8% after surgery (hazard ratio 1.13 relative, 95% CI 1.02 to 1.25; P=0.02). By access route, transfemoral mortality was similar (83.9% versus 82.1%; P=0.27), while transthoracic-access mortality was higher after TAVI (93.2% versus 85.1%; P<0.01; P for interaction=0.03). Cumulative aortic valve reintervention at 10 years was 6.3% after TAVI versus 1.6% after surgery (P<0.001). Among the few patients with 10-year echocardiograms (24 TAVI, 35 surgical), mean gradients were nearly identical (12.6 versus 12.7 mm Hg).

Watch out: The valve is the second-generation SAPIEN XT, implanted in 2011–2013 with a substantial transthoracic-access minority — neither the device nor the access mix matches current transfemoral-first practice, and the authors' own stratification shows the mortality signal rides on the transthoracic cohort. Ten-year echocardiographic data survive for only a few dozen patients, so the gradient comparison is fragile.

Source: Thourani VH et al. 10-Year Randomized Outcomes of Transcatheter or Surgical Aortic Valve Replacement in Intermediate-Risk Aortic Stenosis. Journal of the American College of Cardiology. 2026. PMID: 42300821. Registry ID: ClinicalTrials.gov NCT01314313. MeSH: Humans · Aortic Valve Stenosis/surgery,mortality,diagnostic imaging,diagnosis · Female · Transcatheter Aortic Valve Replacement/methods,mortality · Treatment Outcome · Male · Aged, 80 and over · Follow-Up Studies · Echocardiography · Aged · Time Factors · Heart Valve Prosthesis Implantation/methods · Aortic Valve/surgery,diagnostic imaging · Risk Factors

Card 2 — PARTNER 2 SAPIEN 3 at 10 years (Nazif 2026): propensity-matched mortality 83.4% versus 82.3% (HR 1.01) and reintervention 2.0% versus 1.9% — the third-generation valve matched surgery

Study: Prospective registry with propensity-matched comparison to a randomised surgical cohort (PARTNER 2 SAPIEN 3i, Nazif 2026)

Population: Intermediate-risk patients treated with the third-generation balloon-expandable SAPIEN 3 valve in the PARTNER 2 SAPIEN 3 Intermediate-risk Registry (1,069 TAVI patients, enrolled 2014) compared with the 936 surgical patients of the PARTNER 2A randomised trial, using the same eligibility criteria; after 1:1 propensity matching, 783 patients per group (mean age about 82 years, 43% women, mean STS score 5.5%).

Summary: PARTNER 2 SAPIEN 3 at 10 years (Nazif 2026): propensity-matched mortality 83.4% versus 82.3% (HR 1.01) and reintervention 2.0% versus 1.9% — the third-generation valve matched surgery

Result: At 10 years, all-cause mortality was 83.4% after SAPIEN 3 TAVI and 82.3% after surgery (hazard ratio 1.01 relative, 95% CI 0.91 to 1.13; P=0.82) — the treatment made no difference. Aortic valve reintervention, adjusted for competing mortality, was 2.0% for TAVI and 1.9% for surgery (P=0.47). Among patients with 10-year echocardiograms (32 TAVI, 30 surgical), mean gradients were 11.0 versus 12.6 mm Hg.

Watch out: This is not a randomised comparison: the SAPIEN 3 patients were enrolled a year or more later than the surgical cohort and matched statistically, so era effects and unmeasured differences remain possible despite matching — its 'no difference' carries less weight than a randomised null, and it shares the PARTNER 2A surgical arm with the preceding card rather than adding an independent surgical cohort.

Source: Nazif TM et al. 10-Year Outcomes of SAPIEN 3 Transcatheter Aortic Valve Replacement or Surgery in Intermediate-Risk Patients. Journal of the American College of Cardiology. 2026. PMID: 42300820. Registry ID: ClinicalTrials.gov NCT03222128 (registry record; the surgical comparator trial is NCT01314313). MeSH: Humans · Transcatheter Aortic Valve Replacement/methods,mortality · Female · Aortic Valve Stenosis/surgery,mortality,diagnosis · Male · Treatment Outcome · Registries · Prospective Studies · Aged, 80 and over · Follow-Up Studies · Heart Valve Prosthesis · Risk Assessment · Aged · Time Factors · Risk Factors · Postoperative Complications · Aortic Valve/surgery,diagnostic imaging

Estimate type: adjusted estimate, as stated in the card.

Card 3 — NOTION at 10 years (Thyregod 2024): in lower-risk patients, the composite of death, stroke or MI was identical (65.5% both arms), and severe structural valve deterioration was less frequent after TAVI (1.5% vs 10.0%)

Study: Randomised controlled trial, 10-year follow-up (NOTION, Thyregod 2024)

Population: 280 patients with severe aortic stenosis at lower surgical risk (STS score under 4% in about 80%; mean age about 79 years) randomised to TAVI with the self-expanding CoreValve bioprosthesis (Medtronic; n=145) or surgical bioprosthetic replacement (n=135), followed for 10 years with Valve Academic Research Consortium-3 definitions of bioprosthetic valve dysfunction and failure.

Summary: NOTION at 10 years (Thyregod 2024): in lower-risk patients, the composite of death, stroke or MI was identical (65.5% both arms), and severe structural valve deterioration was less frequent after TAVI (1.5% vs 10.0%)

Result: At 10 years the primary composite of all-cause mortality, stroke or myocardial infarction occurred in 65.5% after TAVI and 65.5% after surgery (hazard ratio 1.0 relative, 95% CI 0.7 to 1.3; P=0.9) — the treatment made no difference, with no difference in any component. Severe structural valve deterioration had occurred in 1.5% after TAVI versus 10.0% after surgery (HR 0.2 relative, 95% CI 0.04 to 0.7; P=0.02); severe non-structural dysfunction in 20.5% versus 43.0% (P<0.001); endocarditis in 7.2% versus 7.4%; and bioprosthetic valve failure in 9.7% versus 13.8% (HR 0.7 relative, 95% CI 0.4 to 1.5; P=0.4). No patient had clinical valve thrombosis.

Watch out: NOTION's patients were mostly LOW surgical risk (STS under 4%), a step below this shelf's intermediate-risk population, and the trial is small (280 patients) with a first-generation self-expanding valve; its durability definitions also count surgical prosthesis–patient mismatch within non-structural dysfunction, which inflates the surgical arm's dysfunction rate relative to a pure deterioration comparison.

Source: Thyregod HGH et al. Transcatheter or surgical aortic valve implantation: 10-year outcomes of the NOTION trial. European heart journal. 2024. PMID: 38321820. Registry ID: none in the record. MeSH: Humans · Male · Aged · Aged, 80 and over · Aortic Valve/surgery · Heart Valve Prosthesis Implantation/adverse effects · Treatment Outcome · Risk Factors · Transcatheter Aortic Valve Replacement/adverse effects · Aortic Valve Stenosis · Heart Valve Prosthesis · Myocardial Infarction/etiology · Stroke/epidemiology,etiology · Endocarditis/surgery · Thrombosis/etiology

Card 4 — Synthesis: at 10 years, TAVI durability in intermediate-risk patients splits by valve generation and access route — not by the catheter approach itself

Study: Synthesis

Population: The carded evidence: one randomised 10-year follow-up in intermediate-risk patients (PARTNER 2A, 1,910 patients), one propensity-matched 10-year comparison of a newer-generation valve against the same surgical cohort (PARTNER 2 SAPIEN 3i, 783 matched pairs), and one randomised 10-year follow-up in lower-risk patients (NOTION, 280 patients). Total carded participants exceed 3,700, so no small-N stamp labelling applies.

Summary: Synthesis: at 10 years, TAVI durability in intermediate-risk patients splits by valve generation and access route — not by the catheter approach itself

Result: Mortality at 10 years: 86.1% versus 82.8% favouring surgery with the second-generation SAPIEN XT (HR 1.13 relative), driven by transthoracic access; 83.4% versus 82.3% (HR 1.01 relative) with the third-generation SAPIEN 3; composite death/stroke/MI identical at 65.5% in NOTION. Reintervention: 6.3% versus 1.6% (XT), 2.0% versus 1.9% (SAPIEN 3). Severe structural deterioration in NOTION: 1.5% TAVI versus 10.0% surgery. SPLIT (device generation and access route): TAVI is as durable as surgery at 10 years in its modern transfemoral, newer-generation form; the early-generation transthoracic experience was not. The 1-year comparison stays homed on live shelf #3360 and is not re-carded here.

Watch out: Ten-year mortality above 80% in the intermediate-risk cohorts means most patients died with, not of, their valve — durability conclusions rest on the minority who survived, on small echocardiographic subsets, and on reintervention rates that competing mortality compresses; a 60-year-old choosing today still has no direct 10-year randomised data in their own age band.

Source: Synthesis of Thourani VH et al. Journal of the American College of Cardiology. 2026 (PMID: 42300821); Nazif TM et al. Journal of the American College of Cardiology. 2026 (PMID: 42300820); Thyregod HGH et al. European heart journal. 2024 (PMID: 38321820).